Home Companies Guangdong Air Giant Fire Equipment Co.,Ltd.

Automatic Fm200 Fire Suppression System Without Pollution for Data Center

Guangdong Air Giant Fire Equipment Co.,Ltd.

Contact Us

[China] country

Trade Verify

Address: Factory 101, Building 2, No. 2, Shaxing Road, Lanhe Town, Nansha District, Guangzhou,China

Contact name:Missaya Lu

Inquir Now

Guangdong Air Giant Fire Equipment Co.,Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Automatic Fm200 Fire Suppression System Without Pollution for Data Center

Country/Region china
City & Province guangzhou
Categories Laser Pointers
InquireNow

Product Details

Automatic Fm200 Fire Suppression System Without Pollution for Data Center

 

HFC-227ea (also known as Fm200) gas is a kind of colorless, odorless and clean fire agent used widely all around the world.Compared to other kinds of fire agents like CO2 and halon, HFC-227ea is more environmentally friendly for it will not hurt the zone layer but others will. HFC-277ea gas has ozone depleting possibility of zero.

 

What’s more, HFC-227ea has all advantages that other fire agents have, like nontoxic, noncorrosive and electrical insulated so that HFC-227ea gas is considered as the optimum substitute to halon series.

 

HFC-227ea can put out fire efficiently in 10s without leaving any residues, so users do not need more money and time to clean up the places after this HFC-227ea system is activated.

 

 

Components

 

The pipe network model of fm200 fire suppression system consists of actually three parts: the pipe network part, the fire fighting equipment part and the electrical elements part. Here will explain the last two parts for customers.

 

The electrical elements is a set of detecting device, and it always plays a subsidiary role in each system. The electrical elements includes:several control panels, several manual buttons, some discharge indicator lights, some alarm bells, some sounder with light, some smoke detectors and heat detectors.

The main part of the system is fire fighting equipment. It is formed by several components: fm200 cylinders, a cylinder frame, nitrogen-pressure driving devices, a driving device frame, container valves, flexible hoses, liquid flow check valves, gas control pipes, gas flow check valves, manifolds, safety valves, selective valves, flanges, elbows and nozzles.

 

Working principle

 

Here is the illustration of working principle to whole system

 

 

 

Application

 

The pipe network type fm200 fire suppression system is suitable for a lot of places and several kinds of fires. The followings are some examples for customer as reference:

 

- Telecommunications and data processing

- Switch gear rooms

- Military applications and cell sites

- High-tech medical application

- Computer rooms

- Telecommunication centers

- Records and data archives

- Testing/imaging equipment

- Reference material

- Chemical laboratories

 

 

Advantages

 

There are a lot of advantages of the single zone fm200 fire suppression system compared to other fire suppression system.

 

1/ It is the single zone fm200 fire suppression system that can protect the largest volume among the fm200 fire suppression system. Only a single zone system can protect at most 3600 cubic meters.

 

2/ Using single zone fm200 fire suppression system can help saving money. Obviously, using several systems are more expensive than only using one.

 

3/ It helps saving place. Because it needs a separate room outside but next to the protected zone, so it won’t waste the places in the protected zone.

 

4/ The single cylinder has large capacity. It has 120l, 150l, and 180l capacity.

 

 

Packages

 

We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.

Hot Products

Environment-Friendly Fm200 Fire Suppression System Without Pollution for Telecommunication Room ...
High-Quality Fm200 Fire Suppression System Without Pollution for Computer Room The main advantage of ...
Insulated Fm200 Fire Suppression System Without Pollution For Computer Room 1. Multiple management ...
Enclosed Flooding Fm200 Fire Suppression System Without Pollution for Museum Though Fm200 is a new ...
Automatic Fm200 Fire Suppression System Without Pollution for Data Center HFC-227ea (also known as ...
Fm200 Gas System Without Pollution for Storage Room • Automatic HFC-227ea/FM200 fire extinguishing ...