Home Companies Zhangjiagang HuaDong Boiler Co., Ltd.

Biomass Boiler Economizer With Carbon Steel Seamless Tube H Fin High Frequency Welding

Zhangjiagang HuaDong Boiler Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Address: N0.1, Dongli Road, Donglai, Zhangjiagang City, Jiangsu Province, China

Contact name:Sandy Chen

Inquir Now

Zhangjiagang HuaDong Boiler Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Biomass Boiler Economizer With Carbon Steel Seamless Tube H Fin High Frequency Welding

Country/Region china
City & Province jiangsu
Categories Boiler Parts
InquireNow

Product Details

Biomass Boiler Economizer With Carbon Steel Seamless Tube H Fin High Frequency Welding

 

Quick Details Specifications


The boiler economizer is an indispensable mechanical device for coal fired boilers, and is located at the boiler flue, where heat is captured from the flue gas in order to pre-heat cold water inlet or heat the boiler feed water. Our economizers are generally made of 20 low and medium pressure boiler pipes, 20G seamless steel tubes or ASME grade steel tubes. It reduces the flue gas temperature and maximizes the heat recovery to help customers reduce fuel costs. When entering the steam drum, the temperature of the feed water is increased after it has been heated using the economizer. The thermal stress caused by the temperature difference between the steam drum wall and the feed water is reduced, which reduces the shrink and swell in the steam drum. Our economizer is an excellent, less expensive replacement for high temperature boiler water wall tubing, thus reducing manufacturing costs for coal fired boilers.

 

(1) The economizer is a steam generation system as like a boiler. when the exhaust gas discharge from the engine cylinder through the exhaust valve it goes to the boiler for generate steam by heating of water.

 

(2) After those gas it goes through the economizer the remaining exhaust gas temperature is heated the water in economiser. it help to generate steam, and it is improving the efficiency and save the fuel consumption

 

(3) An economizer uses the waste heat from the boiler exhaust, that would otherwise be lost to atmosphere to (in most cases) preheat the feed water into the boiler.This improves the boiler efficiency and reduces fuel costs.

 

Competitive Advantage

 

1.Fuel saving: After the high temperature fuel gas released by fuel combustion transfers to the boiler water wall tubing, superheater, and reheater, the temperature is extremely high, the economizer makes it ideal for preventing heat loss. The economizer located at the flue of the boiler reduces the flue gas temperature, and maximizes the heat recovery to lower customer fuel costs.

 

2.Improvement of boiler steam drum working conditions: When entering the steam drum, the temperature of the feed water is increased after it has been heated using the economizer. The thermal stress caused by the temperature difference between the steam drum wall and the feed water is reduced, thus reducing the shrink and swell of the steam drum, and extends the service life.

 

3.Cost reduction of coal fired boilers: Water is being heated in the boiler economizer made using low temperature material. This makes the economizer a less costly replacement for high temperature boiler water wall tubing, and reduces overall boiler manufacturing costs.

 


Economizers must be sized for the volume of flue gas, its temperature, the maximum pressure drop allowed through the stack, what kind of fuel is used in the boiler, and how much energy needs to be recovered. Economizers designed for natural gas only, would likely plug-up if installed on a coal boiler and would face increased risk of corrosion if installed on an oil-fired boiler. Some units are designed to keep the flue gases above condensation temperature, and others are made of materials that resist the corrosive effect of condensed flue gases.

Highly Accuarcy Industrial Coal Fired Boiler Stack Economizer For Power Plant

 

 

 

Parameters

NameEconomizer
specifications of finned tubeunit(mm)
Bare pipe(od)25-165
bare pipe(thick)2-8
finned thicks0.6-3.0
finned height5-30
finned tube thread pitch5-30
finned tube length≤12000

*Note:HD BOILER can bespoke special type of economizer according to customer's requirement.

 

Internal heat exchangers

 

1.Subcooling may also be produced by superheating the gas leaving the evaporator and heading to the gas compressor.

2.These systems withdraw heat from the liquid line but heat up the gas compressors suction.

3.This is a very common solution to insure that gas reaches the compressor and liquid reaches the valve.

4.It also allows maximum heat exchanger use as minimizes the portion of the heat exchangers used to change the temperature of the fluid,and maximizeds the volume in which the refrigerant changes its phase.

 


 

Hot Products

Biomass Boiler Economizer With Carbon Steel Seamless Tube H Fin High Frequency Welding Quick Details ...
Boiler Economizer With Headers Spiral Finned Tube For Waste Heat Boiler Product Description ·Boiler ...
Factory Coal Fired Boiler Stack Economizer / Waste Heat Boiler Exchanger Product Description Boilers ...
Boiler Economizer With Headers Spiral Finned Tube For Biomass Boiler ASME Product Description ...
Boiler Heat Exchanger , Boiler Spiral Fin Tube Economizer ,Economizer Module Spiral Finned Tube ...
Boiler Economizer With Spiral Finned Tube For Waste Heat Boiler Heat Exchanger Product Description ...