Home Companies Shenzhen Begate Technology Co.,Ltd.

OEM ODM OS1 OS2 OM3 OM4 OM5 SM MM 8F 12F 24F 48F 72F 96F 144F ELITE MPO MTP CABLE

Shenzhen Begate Technology Co.,Ltd.
Active Member

Contact Us

[China] country

Address: 3rd floor, Jinluan international business center, Longhua Street, Longhua District, Shenzhen, China.

Contact name:Candy Tang

Inquir Now

Shenzhen Begate Technology Co.,Ltd.

OEM ODM OS1 OS2 OM3 OM4 OM5 SM MM 8F 12F 24F 48F 72F 96F 144F ELITE MPO MTP CABLE

Country/Region china
City & Province shenzhen
InquireNow

Product Details

OEM ODM OS1 OS2 OM3 OM4 OM5 SM MM 8F 12F 24F 48F 72F 96F 144F Elite MPO MTP Cable

 

 

Overview of MPO MTP Cable


MPO MTP cable assembly use MPO or MTP multi-fiber connectors. MPO MTP Fiber Patch Cord greatly saves space and is very convenient to use. 

MTP/MPO Patch Cord features multi-fiber connections in the same single-core fiber optic patch cord. Except for Standard MTP/MPO cable assemblies including MPO harness cable, shuffle cable, hydra cable and trunk cable, Begate also provide other types like IP68 MTP/MPO fiber cable, MTP/MPO loopback adapter and so on for different applications.

 

Features of MPO MTP Cable


  1. MTP and MPO are available
  2. High performance in IL&RL
  3. 100% pre-terminated tested
  4. Pulling eye design easy for cabling
  5. Suitable for MTP/MPO application
  6. Jacket material: LSZH, OFNR, OFNP available
  7. Compliance with Telcordia GR-1435-CORE Compliant
  8. Compliance with UL 94-V0 compliant
  9. RoHS compliant
  10. Supports up to 8F, 12F, 24F, 48F, 72F, 96F, 144F, customized products are available

Application of MPO MTP Cable 


  1. Data communication network.
  2. Optical System Access network.
  3. Storage area networking fiber channel.
  4. High density architectures.
  5. Data Centers
  6. 40/100G applications
  7. Storage area network- fiber channel
  8. Parallel optics
  9. InfiniBand
  10. The internal connector application in fiber equipment

Types of MTP/MPO Cable Assemblies


MPO MTP Fiber Optic Trunk Cables 

 

 

MPO MTP trunk cabling connects MPO MTP modules together as a permanent link. They facilitate rapid deployment of high-density backbone cabling in data centers and other high-density fiber environments, reducing network installation or reconfiguration time and cost. Its efficient plug-and-play structure greatly reduces the initial installation and routine maintenance costs. Pre-terminated trunk cables can also be used with plug-and-play modules or MTP/MPO connector panels to achieve multi-level connection. Pre-terminated trunk cable can also be extended by MTP/MPO panel with the plug-and-play module. They are used to interconnect module cassettes, panels or ruggedized MTP/MPO fanouts, spanning MDA, HDA and EDA zones.

 

General Specification of MPO MTP Trunk Cable:

ConstructionDescription
Fiber Count4-384 Fibers
Fiber ModeSingle mode: OS2/G657 9/125um
Multimode: OM3(50/125um); OM4(50/125um);OM5
Cable Jacket RatingsLow Smoke Zero Halogen (LSZH)
Riser (OFNR)
Plenum (OFNP)
Cable Jacket ColorOS2/G.657: Yellow
OM3: Aqua
OM4: Aqua/Magenta
or Customized
PolarityType A, Type B, Type C (TIA-568.3-D)
Connector Ferrule12F/16F/ 24F/32F/48F
Connector Ferrule BrandUS Conec, HANKUSAN, Nissin
Connector TypeMale; Female
Connector BrandUS Conec MTP, Senko MPO, Nissin MPO, Sanwa MPO, FURUKAWA MPO
Connector Color SM(APC)SM(PC)OM3OM4OM5or
Low lossYellowYellowAquaAqua;MagentaGreenCustomized
StandardGreenBlueAquaAqua;MagentaGreen 
Connector Boot ColorGreen/Black/Red/Gray or Customized
Pulling eyeCustomized
Operating Temperature-20°C to +70°C
Storage Temperature                                                       -45°C to +85°C

 

Technical specification of MPO MTP Trunk Cable:

Optical PropertiesSingle modeMultimode
Insertion Loss (dB)Low loss≤ 0.35 (Typical:≤ 0.25 )Low loss≤ 0.35 (Typical:≤ 0.2 )
Standard Loss≤0.75 (Typical:≤ 0.4 )Standard Loss≤ 0.6 (Typical:≤ 0.35 )
Return Loss (dB)PC≥50; APC≥60PC≥20; APC≥40
Durability≤0.2 dB typical change, 50 matings
Wavelength (nm)Single mode: 1310/1550, Multimode: 850/1300
Fiber Attenuation (dB/km)Single mode: ≤0.35 at 1310nm, ≤0.2 at 1550nm
Multimode: ≤2.3 at 850nm, ≤0.6 at 1300nm
Transmission DistanceOM4: 150m at 40/100G, 550m at 10G
OM3: 100m at 40/100G, 300m at 10G

 

MPO MTP Shuffle Cable Assemblies 

 

 

MTP/MPO Shuffle cable is also used for connecting MTP modules together as a permanent link, and it also be used with plug-and-play modules or MTP/MPO connector panels to achieve multi-level connection of the extension of the pre-terminated trunk cable by MTP/MPO panel. Normally, the shuffle cables are used to interconnect cassettes, panels, or ruggedized MTP/MPO fanouts, spanning MDA, HDA, and EDA zones. The difference is that its optical fiber routing is formulated according to the requirements of the optical connection at the construction site, which can realize special optical fiber routing different from the conventional polarity, reducing network installation or reconfiguration time and cost.

 

General Specification of MPO MTP Shuffle cable:

ConstructionDescription
Fiber Count12-288 Fibers
Fiber ModeSingle mode: OS2/G657 9/125um
Multimode: OM4 50/125um, OM3 50/125um
Cable Jacket RatingsRiser (OFNR)
Plenum (OFNP)
Low Smoke Zero Halogen (LSZH)
Cable Jacket ColorOS2/G657: Yellow
OM3: Aqua; OM4: Aqua/Magenta
or Customized
PolarityCustomized
Connector Ferrule12F/16F/ 24F/32F/48F
Connector Ferrule BrandUS Conec, HANKUSAN, Nissin
Connector TypeMTP Female, Male; MPO Female, Male
Connector BrandUS Conec MTP, Senko MPO, Nissin MPO, Sanwa MPO, FURUKAWA MPO
Connector ColorFerruleSM(APC)SM(PC)OM3OM4or
Low lossYellowYellowAquaMagentaCustomized
StandardGreenBlueAquaMagenta 
Connector Boot ColorGreen/Black/ or Customized
Pulling eyeCustomized
Operating Temperature-20°C to +70°C
Storage Temperature                                                  -45°C to +85°C

 

Technical specification of MPO MTP Shuffle cable:

Optical PropertiesSingle modeMultimode
Insertion Loss (dB)Low lossStandardLow lossStandard
≤0.35(Typical:≤0.25)≤0.75(Typical:≤0.4)≤0.35(Typical:≤0.2)≤0.5(Typical:≤0.35)
Return Loss (dB)PC≥50; APC≥60PC≥20; APC≥40
Wavelength (nm)1310/1550850/1300
Durability≤0.3 (dB)typical change, 50 matings
Fiber Attenuation (dB/km)Single Mode: ≤0.35 at 1310nm, ≤0.2 at 1550nm
Multimode: ≤2.3 at 850nm, ≤0.6 at 1300nm

 

MPO MTP Harness Fanout Cable

 

MPO MTP harness cables are a kind of MPO MTP fanout harness cable or breakout cable assembly with one MPO MTP connector on one end and multiple single-fiber connectors (LC, SC, FC, etc.) on the other end, designed for data distribution and routing to patch panels. It is used to transition from trunk backbone assemblies to fiber rack systems. The MTP harness cable is fully configurable, available with a variety of cable and connector combinations. For the hardware and equipment in the same cabinet, the longer MPO cord can provide flexibility at any location, and the branch MTP/MPO cable can be winded into the vertical cable organizer.

 

General Specification of MPO MTP Harness Fanout Cable:

ConstructionDescription
Fiber Count8-288 Fibers
Fiber ModeSingle mode: OS2/G657 9/125um
Multimode: OM4 50/125um, OM3 50/125um
Cable Jacket RatingsRiser (OFNR)
Plenum (OFNP)
Low Smoke Zero Halogen (LSZH)
Cable Jacket ColorOS2/G657: Yellow
OM3: Aqua; OM4: Aqua/Magenta
or Customized
PolarityA/B/C or Customized
MPO MTPFerrule12F/16F/ 24F/32F
Ferrule BrandUS Conec, HANKUSAN, Nissin
Connector TypeMTP Female, Male; MPO Female, Male
Connector BrandUS Conec MTP, Senko MPO, Nissin MPO, Sanwa MPO, FURUKAWA MPO
Connector ColorFerruleSM(APC)SM(PC)OM3OM4or
Low lossYellowYellowAquaMagentaCustomized
StandardGreenBlueAquaMagenta 
Boot ColorGreen/Black/ or Customized
Single-fiber connectorLC, SC, FC, etc.
Pulling eyeCustomized
Operating Temperature-20°C to +70°C
Storage Temperature                                                  -45°C to +85°C

 

Technical specification of MPO MTP Harness Fanout Cable:

Optical PropertiesSingle modeMultimode
Insertion Loss (dB)Low lossStandardLow lossStandard
≤0.35(Typical:≤0.25)≤0.75(Typical:≤0.4)≤0.35(Typical:≤0.2)≤0.5(Typical:≤0.35)
Return Loss (dB)PC≥50; APC≥60PC≥20; APC≥40
Wavelength (nm)1310/1550850/1300
Durability≤0.3 (dB)typical change, 50 matings

 

Generic Connector Termination
Optical PropertiesSingle modeMultimode
Insertion Loss (dB)≤0.2≤0.2
Return Loss (dB)PC≥55; APC≥60PC≥25
Wavelength (nm)1310/1550850/1300
Durability≤0.2(dB)typical change, 500 matings

 

MPO MTP Hydra Cable 

MPO MTP Hydra cable assemblies is deployed inside plug and play cassette modules. It is used for multi-fiber to single-fiber splitting out interconnects. This solution is a 12-colored 0.9mm cable utilizing an MPO/MTP connector on one end and generic connectors (such as LC, SC, FC, etc.) on the other end. They are available for purchase as a bundle with plug and play modules, MPO MTP Adapter Plates, and other solutions. It is fully configurable, available in 8/12/16/24 fibers versions as well as Multi-mode (Standard 50/125, 62.5/125, BI 10Gig 50/125) and Single-mode fiber types.

 

General Specification of MPO MTP Hydra cable:

ConstructionDescription
Fiber Count8~24 Fibers
Fiber ModeSingle mode: OS2/G657 9/125um
Multimode: OM4 50/125um, OM3 50/125um
Cable Jacket RatingsPVC, LSZH, Hytrel
Cable Jacket ColorBlue, Orange, Green, Brown, Grey, White, Red, Black, Yellow, Purple, Pink, Aqua
PolarityA/B/C or Customized
MPO MTPFerrule12F/16F/ 24F
Ferrule BrandUS Conec, HANKUSAN, Nissin
Connector TypeMTP Female, Male; MPO Female, Male
Connector BrandUS Conec MTP, Senko MPO, Nissin MPO, Sanwa MPO, FURUKAWA MPO
Connector ColorFerruleSM(APC)SM(PC)OM3OM4or
Low lossYellowYellowAquaMagentaCustomized
StandardGreenBlueAquaMagenta 
Boot ColorGreen/Black/ or Customized
Single-fiber connectorLC, SC, FC, etc.
Operating Temperature-20°C to +70°C
Storage Temperature-45°C to +85°C

 

Technical Specification of MPO MTP Hydra cable:

MPO / MTP Termination
Optical PropertiesSingle modeMultimode
Insertion Loss (dB)Low lossStandardLow lossStandard
≤0.35(Typical:≤0.25)≤0.75(Typical:≤0.4)≤0.35(Typical:≤0.2)≤0.5(Typical:≤0.35)
Return Loss (dB)PC≥50; APC≥60PC≥20
Wavelength (nm)1310/1550850/1300
Durability≤0.3 (dB)typical change, 50 matings

 

Generic Connector Termination
Optical PropertiesSingle modeMultimode
Insertion Loss (dB)≤0.2≤0.2
Return Loss (dB)PC≥55; APC≥60PC≥25
Wavelength (nm)1310/1550850/1300
Durability≤0.2(dB)typical change, 500 matings

 

Assembly line of MPO MTP Cable 


We are dedicated to providing customers with the outstanding, standards-compliant products and services.


Begate has passed ISO9001 quality system verification, and our products are approved by CE, RoHS. Compliant with IEC and TIA requirement. We established an internationally standardized quality assurance system and strictly implemented standardized management and control in the course of design, development, production, installation and service.

 

Please Note: Each fiber patch cable is 100% optically inspected and tested for insertion loss before you receive it.

Shipping and Delivery of MPO MTP Cable 


Every cooperation is a kind of trust, Begates cares about the issues that our customers care about.

While ensuring product quality, we provide customers with safe packaging, so that the goods can be delivered to customers in good condition.

 

Question: How long is shipping take typically?

Reply: The delivery time depends on the goods quantities. If light weight, by express (DHL, FEDEX, TNT, UPS, Special line) will take about 10-15days, if large quantities with big volume, and goods are not in urgently needed, by ocean transportation will be more cost effective, it will take around 30-60days.

 

MPO MTP series products for Data Center Solution


  1. MPO/MTP Trunk Cable
  2.  MPO/MTP Harnesses Cables
  3. MPO/MTP Fan out 0.9mm Patch Cords
  4.  IP-Series MPO/MTP Assembly
  5. High Density Patch Cords
  6. MPO/MTP Loopback
  7. MT Patch Cords
  8. MPO/MTP Cassettes
  9. MPO/MTP Fiber Optic Patch Panel

FAQ


Q1: Are you a manufacturer?
A: Yes, we are a manufacturer who has 3 factories and welcome to visit!
Q2: What is your MOQ?
A: We are the factory. No MOQ, One piece is available.
Q3:Can you provide the OEM service?
A: Sure, we have the complete production line, we could do the production as your request.
Q4. Can I have a sample order for this product?
A: Yes, for patchcord, FREE SAMPLE is avaible to test and check quality. Mixed samples are acceptable.
Q5: How long is your delivery time?
A: Generally it is 2-5days if the goods are in stock. or it is 7-15 days if the goods are out of stock. The lead time mainly depends on quantity.
Q6: Can I negotiate the prices?
A:Yes, special discounts are available. The more quantities, the cheaper prices.
Q7: How much will the shipping charges be?
A:It depends on the size of your shipment and the method of shipping. We will offer the charge to you as per you requested.

 

More questions?


Our informative and experienced representatives are ready to assist you with any questions that you might have, regarding your fiber optic network. We offer a superior selection of quality products as well as competitive pricing to help get your project completed and under budget.
Thank you for visiting our website!

Hot Products

OEM ODM OS1 OS2 OM3 OM4 OM5 SM MM 8F 12F 24F 48F 72F 96F 144F Elite MPO MTP Cable Overview of MPO ...
Duplex OM4 Multimode Type B Fiber Optic Cable LC UPC LSZH Breakout Cable MPO Product Description of ...
1x8 1x16 1x32 SC UPC Fiber Optic PLC Splitter Mini Steel Type Green PLC Fiber Splitter Products ...
ODVA To LC Waterproof Fiber Optic Patch Cords For FTTA RRH RRU FTTX ODVA to LC Outdoor Waterproof ...
ODVA To SC Optical Patch Cable Waterproof Fiber To The Antenna ODVA To SC Waterproof Fiber To The ...
Customized OM1 OM2 Duplex Fiber Optic Patch Cords 850nm Wavelength SMA fiber optic patch cords are ...