Custom Made Three Zones High and Low Temperature impact Test Chamber For GJB Standard


1. Quick Details

 

Alternative nameThree Zones Thermal Shock Tester
FunctionTesting material structure or composite materials in instant and
continuous temperature changing environment, check the chemical
and physical damage.
Provides basis and reference to improve quality of products
TypeThree zones
Weight180kg
Internal space1510mm*1730mm*1660mm
Corresponding test standardGJB150, GJB360, GBJ367, GB/T5170, GB10592



2. Description

Thermal shock tester also is named rapid temperature changing tester or thermal cycling chamber.
The tester is used for testing material structure or composite materials.
The specimen will be exposed to continuous and instant changing circulation of extreme high and low
temperature.
Then check the chemical change and physical damage of the specimen caused by instant temperature
change.
The tester is applied to mental, plastics, rubber, electronics. The test can provides basis and reference
to improve quality of products.
The tester is divided into high temperature zone, low temperature, and test tank.
The specimen shall be still, while the tester employ special coldness and heat storage system. The cold
and hot wind will be switched and channeled to the test tank in moment, and finish the test when get the
set time.


3. Features

 

a. The tester is used for test chemical change and physical damage of specimen after suffering

instant extreme high and low temperature change.

b. The tester is divided three zone.

c. Widely usage.

 

4. Specifications

 

ModelJB-3000-CH
Temperature range of test tank-40℃~+150℃
Preheating range of high temperature tank+60℃~+150℃ (30min, room temperature +
10~+30℃)
Precooling range of low temperature tank-10℃~-40℃
Cooling time for low temperature tankAbout 80min from +20℃ to -40℃ (room temperature
+10~+30℃)
Temperature Fluctuation±2.0℃
Temperature uniformity±3.0℃
Temperature shock recovery time

Within 5min

 

Hot Products

DIN-VDE0620-1 Plug And Socket Gauge For Measuring German Standard Plug And Socket Product informatio...
G10q , GX10q, GY10q,GZ10q Lamp cap gauge , "GO" GAUGE FOR CAPS C G10q, GX10q, GY10q , GZ10q GO" ...
ISO 8124-1 2014 Stainless Steel Protrusion Test Gauge Technical Parameter Material Stainless steel ...
IEC 62368 Edition 3, CDV Steel Disc, Aluminium Ring And Aluminium Foil For Wireless Charge The ...
Zhaga book 18 -Annex B Mechanical drawing of the Mechanical-stop-gauge 5.1.1 Mechanical-stop-gauge ...
IEC 62368 Edition 3 Figure 47 Figure 48 Figure 49 Foreign Metallic Objects with Insulation Board for ...