Neware 5V12A 8 Channel Battery Cycler Pouch Polymer Cells Tester
Neware Battery Charge and Discharge Test System , ranging from μA
single cell applications up to 1MW packs , is a high precision
system designed specifically for testing lithium ion battery cells
, modules , packs and capacitors . It is suitable for product
development, quality control , and helpful to characteristic
research , cycle life testing , product screening, and quality
assessment .
Software Feature
1 , Windows - based software interface for easy operation .
2 , Uses standard SQL data - base management .
3 , Real - time monitoring windows and integrated graph / data
windows can set various working modes for measuring capacity and
cycle life of all types of rechargeable batteries , such as
constant current discharge , constant current charge , constant
voltage charge , rest , as well as voltage , current , time ,
capability , negative voltage slope , and other limit conditions .
4 , The user can define the curve by different types such as
voltage - time curve , current - time curve , capacity - voltage
curve ,
loop times - charge / discharge capacity curve , loop times -
charge / discharge efficiency curve , etc . to make curves be
compared both by visually and statistically .
5 , Provide timely instructions , warnings , and intelligent
support .
6 , Compliance CE Certified .
HPPC , Capacity , Cycle Life , Formation and Grading ,
Over - charge , Over - discharge
Market - proven Testing System
Less than 20ms Response Time to Meet Rapidly Changing Power
Requirements
0.1 percent Full - scale Accuracy for Current and Voltage
10Hz Data Acquisition Frequency , 100Hz Optional
500ms Minimum Pulse Width More Than 1 Million Records Can Be
Processed
Power | Per Channel Output Power | 30W |
Stop current | Range 1 , 2mA Range 2 , 12mA Range 3 , 24mA |
Stability | 0.1percent of FS |
Time | Current Response Time | 1ms |
Data Recording | Record Condition | Min Time - 100mS |
Min Voltage - 10mV |
| Min Current - Range 1 , 2mA Range 2 , 12mA Range 3 , 24mA |
Record Frequency | 10Hz |
Charge | Charge Mode | CCCharge , CVCharge , CCCVCharge , CPCharge |
End Conditon | Voltage , Current , Relative Time , Capacity , -deltaV |
Discharge | Discharge Mode | CCD , CPD , CRD |
End Condition | Voltage , Current , Relative Time , Capacity |
Pulse | charge | CCC , CPC |
Discharge | CCD , CPD |
Min Pulse Width | 500ms |
Automated Switch | Automated swith from charge to discharge for each pulse |
End Condition | Voltage, Test Time |
Cycle | Loop Measure Range | 65535 times |
Max Steps Per Loop | 254 |
Nested Loop | Nested loop Function , Max Support 3 Layers |
![](http://img.everychina.com/nimg/5f/53/ee50d4d8e84913ad293f3722c546.jpg)