Neware 5V6A Phone Battery Cell Tester Lead Acid Charge and Discharge Cycler

 

1 . Battery researchers and scientists , battery manufactures , importers and exporters , you can always choose the most appropriate Neware battery testers for battery quality check , battery performance tests , battery material research , and battery mass production lines .

 

2 . 5V6A Battery Testing System is mainly used for testing polymer batteries , cylindrical batteries and super capacitors . The test of polymer batteries and super capacitors need Neware special accessories . Cylindrical batteries need to be clamped between the upper and down clamps of the equipment . By moving the position of the upper accessory accurately according to the scales on both sides , you can test different capacities of Cylinders Batteries .

 

3 . Neware 5V6A is powerful , reliable , it works on the very popular coin cell , cylindrical cell and prismatic cells , etc . It can be used for battery formation and grading , cycle - life test , performance and so on . From year 2016 , dual range 5V6A was successfully replaced the traditional 5V6A model . Higher range 100mA - 3A - 6A , makes it the best choice for cycle - life test and C - Rate test on 3C battery cells . Lower range 0.5mA - 100mA - 1A , makes 5V6A great for small pouch , coin cell and small battery test .

 

4 . Specialized in testing 18650 / 26650 / 21700 / 32650 Cylindrical Battery , Pouch Battery , Super Capacitor , etc .

 

5 . The model 5V6A can be configured with multi - current range channels , which have a current control range of 0.5mA to 0.1A , 0.1A to 3A , 3A to 6A as standard . The accuracy for current and voltage on these channels is 0.05 percent of FS . From the base system that provides the highest level of accuracy and time resolution , features can be added to allow the 5V6A test system to perform virtualy many type of test , with many type of products – cylindrical , pouch and coin cells , super – capacitors , etc , and chemistries .

 

6 . To meet the various requirements adopted in advanced battery research , our equipments can automatically switch the current range in accordance with user settings to maintain consistent accuracy , and can be fitted with additional hardware to provide a number of optional features and capabilities .

 

7 . Neware 5V6A is the most popular battery tester ever , more than 50 percent customers would choose this model as their main products . For customers who came across Neware the first time , 5V6A is also strongly suggested as their tryout demo machine .

 

 

Channel FeaturesConstant Current Source and Constant Voltage Source with Independent pairs of Closed - loop Structure
Channel Control ModeIndependent Control
VoltagePer Channel Voltage Range1.5V - 5V
Discharge Min Voltage1.5V
CurrentPer Channel Current RangeRange1 , 5mA - 1A Range2 , 1A - 6A Range3 , 6A - 12A
Accuracy0.05 percent of FS
Stability0.05 percent of FS
Data RecordingRecord ConditionMin Time - 100mS
Min Voltage - 10mV
 Min Current - Range 1 , 2mA Range 2 , 12mA Range 3 , 24mA
Record Frequency10Hz
ChargeCharge ModeCCCharge , CVCharge , CCCVCharge , CPCharge
End ConditonVoltage , Current , Relative Time , Capacity , -deltaV
DischargeDischarge ModeCCD , CPD , CRD
End ConditionVoltage , Current , Relative Time , Capacity
PulsechargeCCC , CPC
DischargeCCD , CPD
Min Pulse Width500ms
Automated SwitchAutomated swith from charge to discharge for each pulse
End ConditionVoltage, Test Time
CycleMax Steps Per Loop254
Nested LoopNested loop Function , Max Support 3 Layers
ProtectionSoftware ProtectionPower - down Data Protection
Off - line Testing Function
Setting Protection Condition,Setting Parameter - Low Voltage limit , Upper Voltage limit , Low Current limit , Upper Current limit , Delay Time
IP protection levelProtection level IP20
A Means of Communication of Upper MachineTCP / IP Protocol
Data OutputEXCEL , TXT , Graph
Dimensions3U , 480 – 330 - 180mm

 

Hot Products

Polymer Battery Cell Tester 8 Channel Lithium Battery Analyzer Battery researchers and scientists, ...
Button Coin Battery Cell Tester Battery Material dQdV DCIR Pulse Analyzer The system is oriented to ...
Neware 8 Channer Battery Cell Cycle Life Tester Current up to 6000mA 1 . Nowadays people need ...
Neware 8 Channer Battery Cell Tester TWS Battery Capacity Charge and Discharge Cycler 1 . Nowadays ...
Neware 5V6A Phone Battery Cell Tester Lead Acid Charge and Discharge Cycler 1 . Battery researchers ...
Neware 5V6A Battery Cell Testing Solutions 8 Channel Battery Capaccity Tester A . Battery researcher...