Product Details

YY SERIES

PORTABLE SOLAR GENERATOR KIT

12v 50ah 780WH 600W Ups Uninterruptible Power Supply Solar Power Generator

1. Technical parameter

ModelYY600+YY1000+YY1500+YY2000+YY2400+
Rated power600W1000W1500W2000W2400W
DC Input voltage10.5-15V20-29V20-29V40-55V40-55V
AC Input voltage(165-275)VAC
AC Input Frequency45-65Hz
AC Output voltageAC220V±2%(BATTERY MODE)
AC Output Frequency50/60HZ±1%(BATTERY MODE)
DC Output voltage2*DC 5V/1A 2*DC 5V/2.1A 1*12V/10A 1*12V/20A (BATTERY MODE)
Output waveformPure sine wave
Efficiency85%
Transfer time4ms
BatteryLiFePo4
Battery capacity12v50ah24V20AH48V26AH48V26AH48v26ah
Max AC Charge current0-40A(Optional)
AC Charge time5H6H8H10H12H
Solar input voltage

PWM (12V TO 25V, 24V TO 50V, 48V TO 80V)

MPPT (12/24/48V TO 72V/150V)

Solar charge current40A
Solar panel *150W150W*2200*2W280W*2330W*2
Solar panel charge time6H7H7H8H8
ProtectionOver voltage, over term, over load, short circuit, battery voltage high & low,AC input voltage high & low, automatic re-cover
Overload capacity110-125%,turn to by pass after 60 secs,over 125% maintain 10 secs and then shut down
Communication interfaceRS-232/USB (Optional)
Operation term-25~55°C
Humidity5%~90%( non-condensation)
Noise≤ 45dB (with in 1 Meter)
Altitude≤ 4500m
CoolingAir cooling(inner term over 45°C) when machine temperature is up to 45℃, fan works; when it’s lower than 45℃, fan stop automatically.
MTBF50000H
DimensionL380*W195*H380mm
Package dimensionL470*W280*H420mm
Net weight11kg11.5kg15kg26kg29kg
Gross weight14kg14kg16kg26kg29kg
*Customizable battery capacity and battery type(Lithium,VRLA)

 

 

 

2. Appearance

1KW-3KW series

3. Installation Instruction

3-1.Open up

After opening the package, please check the accessories, including 1 pc of user manual. And please make sure that the inverter is well-protected after transportation, if any damage:

 

Note: component miss, do not turn on the machine, feedback to the carrier and distributor.

 

1). Please retain the packing material, those can be used for next delivery if needed.

2). This series of products is heavy (check attachment as reference), please handle carefully when carrying.

3-2. Installation notice

 

1). Install in an area of well-ventilated, free of water, burning gas and corrosive stuff.

 

2). Not good to stand on sides, should keep good air inlet from front panel’s bottom and side face of machine, air outlet from back panel’s fan.

 

3). Environment temperature should remain from 0 to 40 centigrade.

 

4). When disassembling and operating under low temperature, it may cause water condense, should not turn on until sides of machine being dry, or it will be shock risk.

 

5). Install the inverter near mains socket or switch, in order to pull out mains supply plug to cut off power easily when meeting emergency.

 

Attention:

< Loading should be turned off before connecting to inverter and turned on the loading one by one after connection completed.

< Connect inverter to accessible socket with over-current protection.

< All power sockets should link with ground protection.

< Inverter may have electricity whether input power cable inserts to mains socket or not. Turning off the inverter does not guarantee electricity does not exist. To ensure no output, should turn off all switches and cut the mains power.

< To load inductive appliances such as electromotor, displayer and laser printer, inverter capacity should be two times compared to rated power of the load.

 

 

4. Description of panel

Detail of LCD

1 Input Voltage 2 Working Mode 3 Output Voltage

4 Solar Panel 5 Battery Status 6 Loading Application

7 Silent Mode 8 Loading Status

Detail of indicate lamp & button

 

INPUTAC input voltage
Hzoutput frequency / Working mode
OUTPUTAC output voltage
BATT. CAPACITYBattery working condition and capacity
LOADLoad power
NORMALAC input at normal status
FAULTFalse signal light
BATTERYBattery mode
25%--100%Overload condition
 ENTER
 ON/OFF
 UP
 DOWN
 

5. Function and setting

ON/OFF Button: Press for 3 seconds to turn on and 5 seconds turn off.

ENTER Button: Press for 5 seconds start to set Mode P0 to P4. Switch through UP & DOWN button.

Mode P0- Pre-set. Press ENTER 2 times to end up setting. Auto Exit after 10 seconds' no-ops.

Mode P1- Power supply setting. 01- AC supply in priority, 02- Energy saving. 03- Battery supply in priority, switch through UP & DOWN and select through ENTER button.

Mode P2- Battery Type setting. Switch through UP & DOWN and select battery type through ENTER button.

Mode P3- Charging Current 0-35A selecting. 0-20%-40%-60%-80%-100%, Maximum is 35A, Minimum 0A.

Mode P4- Voice setting. Switch the Buzzer through UP & DOWN and select through ENTER button.

 

PositionFloat(V)PositionFloat(V)
U0=Gel U.S.A13.7VU4=Gel European13.8V
U1=A.G .M.113.4VU5=Open lead acid13.8V
U2=A.G .M.213.7VU6=Calcium (open)13.6V
U3=Sealed lead Acid13.6V  

 

 

 

 

 

 

 

6. Connection

Attention:

Terminal and output plug are both available to connect the load. Output plug can only allow the loading under 1500W. Loading over 1500W should connect to terminal.

Solar wiring diagram

 

Note:

 

If connect to generator, must follow the steps below:

 

  • Start generator, after it go stably, connect its output port to inverter’s input port (to be sure there isn’t any load connecting to inverter at this moment).
  • Start the inverter, connect the loads one by one.
  • Choose generator with 2 or 3 times capacity compared to inverter.
  • Solar inverter’s panel and connection is different from common model.
  • The voltage of solar panel should follow the Technical parameter.

 

Back panel connection

BATTERY NegativeBattery negative polarity connection
BATTERY PositiveBattery positive polarity connection
AC INPUTAC input connection
AC OUTPUTUniversal socket output or terminal output
FUSE AC INPUTAc input voltage over current protection
FUSE AC OUTPUTAc output voltage over current protection
 

 

 

Note:

 

If connect to generator, must follow the steps below:

 

  • Start generator, after it go stably, connect its output port to inverter’s input port (to be sure there isn’t any load connecting to inverter at this moment).
  • Start the inverter, connect the loads one by one.
  • Choose generator with 2 or 3 times capacity compared to inverter.
  • Solar inverter’s panel and connection is different from common model.
  • The voltage of solar panel should follow the Technical parameter.

7. Care and maintenance

This series of inverter fairly needs maintenance. Turn to battery charge mode to extend the life of battery.

 

discharge and charge the batteries at least 1 time every 6 months. Charging time should not be less than 12 hours.

In high temperature area, battery should be charged and discharged every 2 months and standard charging time is not less than 12 hours.

Basically batteries works 3-5 years, should replace when working not well.

 

Ask professionals to replace the batteries.

 

 

Note:

 

  • Before replacing battery, must switch off battery, inverter and mains supply.
  • Put off the metal object like ring, watch etc.
  • Use insulated tool and avoid putting any tool and metal object on battery.
  • When connecting battery, it may strike some un-harmful sparks.
  • Do not make converse connection.

8. Solution for difficult situation

 

FalseCauseSolution
No city power inputRecoverable fuse popupPress fuse back
Terminal heatingFault or loose connectionReconnect
Auto switch off with loadsBattery no power or overloadCharge battery or reduce loads
Switch on failureFault connection with city power or batteryCheck connection with battery or reconnect
Alarm when switch onBattery no energy or overloadCharge battery or reduce loads
Buzzer screams 2 secs every 3 secsOver temperature alarm (85℃-alarm,90℃-shut down)Check if fan or vents jammed
Fan’s speed not stableSmart control according to temperatureLeave it
 

 

Hot Products

YY SERIES PORTABLE SOLAR GENERATOR KIT 12v 50ah 780WH 600W Ups Uninterruptible Power Supply Solar ...
YY SERIES PORTABLE SOLAR GENERATOR KIT YY series portable solar generator is used in printers, ...
YY SERIES PORTABLE SOLAR GENERATOR KIT YY series portable solar generator, is a portable power ...
YB Series Portable Solar Power Generator YB Series Portable Solar Power Generator, It meets the ...
YB Series Portable Solar Power Generator YB Series Portable Solar Power Generator, It meets the ...
YB Series Portable Solar Power Generator YB Series Portable Solar Power Generator is Portable Power ...