NYY-J / -O Low Voltage Cable PVC Insulated Outdoor Fixed Installation Cable

 

APPLICATION

Distribution and signal power cable for static outdoor application (with protection against direct UV-irradiation), in ground, in water, within facilities, in cable canals, in concrete, in conditions where heavier mechanical loads and specially tensile strains, are not expected. Used in electric power plants, transformer stations, industrial plants, metropolitan networks and in other electric plants, same as for connection of signalling devices in industry, traffic and similar.

 

 

CONSTRUCTION

Conductor:Cu, class 1 or 2 acc. to HRN HD 383 / IEC 60228 / DIN VDE 0295

class 1:solid, round(RE) or sector (SE)

class 2:multi wire stranded, round (RM) or sector (SM), multi wire exceeding 50 mm² are compacted

Insulation:PVC compound DIV-4 acc. to HRN HD 603.1

Filler:wrapped thermoplastic tapes

Sheath:PVC compound DMV-5 acc. to HRN HD 603.1

Sheath colour: black

 

 

Standard VDE 0276-603
Direct burial yes
VDE yes
CPR-performance Eca
Conductor material bare copper
Conductor class class 1, from 25 sqmm class 2
Insulation PVC DIV 4
Sheathing material PVC DMV 5
Colour outer sheath black
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
UV-resistant yes
For outdoor use yes
Maximum permitted conductor temperature 70 °C
Permitted outer cable temperature, fixed 70 °C
Permitted outer cable temperature, in motion/during installation -5 - +70 °C

 


 

DIMENSIONS

Number of cores x conductor cross-section Construction Construction of individual conductor External diameter Insulation thickness Conductor resistance at 20 °C Short circuit current 1s Cu weight Cable weight
    nominal min-max. nom. max. nom.    
N x mm²   n x mm mm mm Ω/km kA kg/km kg/km
1 x 4 RE 1 x 2,25 9,0 - 11,0 1,0 4,61 0,46 38,4 110
1 x 6 RE 1 x 2,76 9,0 - 11,0 1,0 3,08 0,69 57,6 130
1 x 10 RE 1 x 3,56 10,0 - 12,0 1,0 1,83 1,15 96 180
1 x 16 RE 1 x 4,51 10,0 - 13,0 1,0 1,15 1,84 153,6 240
1 x 25 RM 7 x 2,13 12,0 - 15,0 1,2 0,727 2,87 240 350
1 x 35 RM 7 x 2,52 13,0 - 16,0 1,2 0,524 4,02 336 460
1 x 50 RM 19 x 1,83 14,0 - 17,0 1,4 0,387 5,75 480 600
1 x 70 RM 19 x 2,17 16,0 - 19,0 1,4 0,268 8,05 672 800
1 x 95 RM 19 x 2,52 18,0 - 21,0 1,6 0,193 10,90 912 1100
1 x 120 RM 37 x 2,03 19,0 - 22,0 1,6 0,153 13,80 1152 1350
1 x 150 RM 37 x 2,27 21,0 - 25,0 1,8 0,124 17,20 1440 1650
1 x 185 RM 37 x 2,52 23,0 - 27,0 2,0 0,0991 21,30 1776 2000
1 x 240 RM 61 x 2,24 26,0 - 30,0 2,2 0,0754 27,60 2304 2600
1 x 300 RM 61 x 2,50 28,0 - 32,0 2,4 0,0601 34,50 2880 3200
1 x 400 RM 61 x 2,89 32,0 - 37,0 2,6 0,047 41,20 3840 4100
1 x 500 RM 61 x 3,23 35,0 - 40,0 2,8 0,0366 51,50 4800 5200
1 x 630 RM 91 x 2,97 41,0 - 45,0 2,8 0,0283 64,00 6048 6650
 
2 x 1,5 RE 1 x 1,38 11,0 - 13,0 0,8 12,1 0,173 28,8 190
2 x 2,5 RE 1 x 1,78 12,0 - 14,0 0,8 7,41 0,288 48 230
2 x 4 RE 1 x 2,25 13,0 - 15,0 1,0 4,61 0,46 76,8 310
2 x 6 RE 1 x 2,76 14,0 - 16,0 1,0 3,08 0,69 115,2 380
2 x 10 RE 1 x 3,56 16,0 - 18,0 1,0 1,83 1,15 192 510
2 x 16 RE 1 x 4,51 18,0 - 20,0 1,0 1,15 1,84 307,2 705
2 x 25 RM 7 x 2,13 22,2 1,2 0,727 2,87 480 1010
2 x 35 RM 7 x 2,52 24,4 1,2 0,524 4,02 672 1285
 
3 x 1,5 RE 1 x 1,38 11,0 - 14,0 0,8 12,1 0,17 43,2 190
3 x 2,5 RE 1 x 1,78 12,0 - 15,0 0,8 7,41 0,29 72 240
3 x 4 RE 1 x 2,25 14,0 - 17,0 1,0 4,61 0,46 115,2 330
3 x 6 RE 1 x 2,76 15,0 - 18,0 1,0 3,08 0,69 172,8 420
3 x 10 RE 1 x 3,56 17,0 - 20,0 1,0 1,83 1,15 288 580
3 x 10 RM 7 x 1,35 17,0 - 20,0 1,0 1,83 1,15 288 580
3 x 16 RE 1 x 4,51 18,0 - 21,0 1,0 1,15 1,84 460,8 810
3 x 16 RM 7 x 1,70 18,0 - 21,0 1,0 1,15 1,84 460,8 810
3 x 25 RM 7 x 2,13 24,0 - 27,0 1,2 0,727 2,87 720 1300
3 x 35 SM 7 x 2,52 22,0 - 25,0 1,2 0,524 4,02 1008 1400
3 x 50 SM 19 x 1,83 25,0 - 29,0 1,4 0,387 5,75 1440 1800
3 x 70 SM 19 x 2,17 29,0 - 34,0 1,4 0,268 8,05 2016 2400
3 x 95 SM 19 x 2,52 33,0 - 37,0 1,6 0,193 10,90 2736 3300
3 x 120 SM 37 x 2,03 35,0 - 40,0 1,6 0,153 13,80 3456 4000
3 x 150 SM 37 x 2,27 39,0 - 44,0 1,8 0,124 17,20 4320 4900
3 x 185 SM 37 x 2,52 45,0 - 50,0 2,0 0,0991 21,30 5328 6500
3 x 240 SM 61 x 2,24 50,0 - 55,0 2,2 0,0754 27,60 6912 8300
 
3 x 25 + 16 RM/RE 7 x 2,13 25,0 - 31,0 1,2 0,727 2,87 873,6 1500
3 x 35 + 16 SM/RE 7 x 2,52 25,0 - 32,0 1,2 0,524 4,02 1161,6 1700
3 x 50 + 25 SM/RM 19 x 1,83 28,0 - 35,0 1,4 0,387 5,75 1680 2300
3 x 70 + 35 SM/SM 19 x 2,17 31,0 - 38,0 1,4 0,268 8,05 2352 2800
3 x 95 + 50 SM/SM 19 x 2,52 36,0 - 43,0 1,6 0,193 10,90 3216 3800
3 x 120 + 70 SM/RM 37 x 2,03 37,0 - 45,0 1,6 0,153 13,80 4128 4700
3 x 150 + 70 SM/SM 37 x 2,27 42,0 - 50,0 1,8 0,124 17,20 4992 5600
3 x 185 + 95 SM/SM 37 x 2,52 44,0 - 52,0 2,0 0,0991 21,30 6240 7400
3 x 240 + 120 SM/SM 61 x 2,24 46,0 - 54,0 2,0 0,0754 27,60 8064 9600
3 x 300 + 150 SM/SM 61 x 2,50 63,0 - 71,0 2,0 0,0601 34,50 10080 11200
 
4 x 4 RE 1 x 2,25 15,0 - 19,0 1,0 4,61 0,46 153,6 400
4 x 6 RE 1 x 2,76 16,0 - 20,0 1,0 3,08 0,69 230,4 510
4 x 10 RE 1 x 3,56 18,0 - 22,0 1,0 1,83 1,15 384 720
4 x 10 RM 7 x 1,35 18,0 - 22,0 1,0 1,83 1,15 384 720
4 x 16 RE 1 x 4,51 21,0 - 25,0 1,0 1,15 1,84 614,4 1050
4 x 16 RM 7 x 1,70 21,0 - 25,0 1,0 1,15 1,84 614,4 1050
4 x 25 RM 7 x 2,13 25,0 - 32,0 1,2 0,727 2,87 960 1600
4 x 35 SM 7 x 2,52 27,0 - 34,0 1,2 0,524 4,02 1344 1750
4 x 50 SM 19 x 1,83 29,0 - 36,0 1,4 0,387 5,75 1920 2300
4 x 70 SM 19 x 2,17 33,0 - 40,0 1,4 0,268 8,05 2688 3100
4 x 95 SM 19 x 2,52 38,0 - 45,0 1,6 0,193 10,90 3648 4200
4 x 120 SM 37 x 2,03 41,0 - 49,0 1,6 0,153 13,80 4608 5200
4 x 150 SM 37 x 2,27 46,0 - 54,0 1,8 0,124 17,20 5760 6400
4 x 185 SM 37 x 2,52 51,0 - 59,0 2,0 0,0991 21,30 7104 8050
4 x 240 SM 61 x 2,24 57,0 - 65,0 2,2 0,0754 27,60 9216 11000
4 x 300 SM 61 x 2,50 63,9 2,4 0,0601   11520 13245
 
5 x 1,5 RE 1 x 1,38 13,0 - 16,0 0,8 12,1 0,17 72 270
5 x 2,5 RE 1 x 1,78 14,0 - 17,0 0,8 7,41 0,29 120 350
5 x 4 RE 1 x 2,25 15,0 - 18,0 1,0 4,61 0,46 192 480
5 x 6 RE 1 x 2,76 18,0 - 21,0 1,0 3,08 0,69 288 610
5 x 10 RE 1 x 3,56 19,0 - 22,0 1,0 1,83 1,15 480 880
5 x 10 RM 7 x 1,35 19,0 - 22,0 1,0 1,83 1,15 480 880
5 x 16 RE 1 x 4,51 22,0 - 25,0 1,0 1,15 1,84 768 1250
5 x 16 RM 7 x 1,70 22,0 - 25,0 1,0 1,15 1,84 768 1250
5 x 25 RM 7 x 2,13 27,0 - 33,0 1,2 0,727 2,87 1200 1950
5 x 35 RM 7 x 2,52 33,0 - 40,0 1,2 0,524 4,02 1680 2400
5 x 50 RM 19 x 1,83 39,0 - 45,0 1,2 0,387 5,75 2400 3500
5 x 70 RM 19 x 2,17 41,0 - 47,0 1,4 0,268 8,05 3360 4450
5 x 95 RM 19 x 2,52 46,0 - 52,0 1,4 0,193 10,90 4560 6134
5 x 120 RM 37 x 2,03 51,0 - 57,0 1,6 0,153 13,80 5760 7483

Hot Products

IEC 60502-1 Standard Two Cores 0.6/1kV PVC Insulated PVC Sheath Cable APPLICATION IEC60502-1 cables ...
318-B LSZH / H05Z1Z1-F Flexible Cable BS EN 50525-3-11 Class 5 LSZH For Public Areas APPLICATION ...
NYFGY Low Voltage Cable Copper Cables With Galvanized Flat Steel Wire Armouring APPLICATION ...
NYSY Low Voltage Cable 0.6/1KV PVC Insulated Copper Tape Screen Power Cable APPLICATION For power ...
NYY-J / -O Low Voltage Cable PVC Insulated Outdoor Fixed Installation Cable APPLICATION Distribution ...
NAY2Y Low Voltage Cable PVC Insulation and HDPE Sheath Shaped Aluminum Conductor APPLICATION NAY2Y ...