Technical Parameter
Items
|
Details
|
Type | Two-station(single-cutter/double-cutter) |
Armature apply range | Armature below 3KG Stack height:30-100mm Armature diameter: Φ60-90mm |
Balancing speed | 1500-2100rpm |
Milling method | R-shape or V-shape |
Power | AC380V |
Air supply | 0.4~0.6Mpa |
Initial unbalance | |
Cycle time | 15-20s |
Residual unbalance eccentricity | Better than the China national standard Grade 6.3 |
Volume (length x width x height) | 1700 X1000X 1550 mm mm |
Maintenance of the system
A. Daily Maintenance
1. Clean the dust and ash on the surfaces of the machine, keep
every part clean.
2. Ensure the power and air supply function well before starting
the system.
3. Check the vulnerable components (leather conveyors, ceramic
sticks, block piece, etc).
Please replace the damaged ones.
B. Monthly Maintenance
1. Check damping of every air cylinder to ensure they can function
smoothly.
2. Lubricate every linear guide and bearing.
3. Add rust preventing oil on the components.
4. Add lube into the flow nipple on the cutters to lubricate the
bearings.
5. Check the filters of the air compressors, dewater them
regularly.
6. Check the status of the dust collector and the filter net to
ensure they can function well.
l Season Maintenance
1. Demagnetize cutters and fixture seats.
2. Check if the cutters are filthy or wearing (1 sharpening/ 0.1
million uses). Check if the
screws are tightened.
3. Check the vulnerable components (leather conveyors, ceramic
sticks, block piece, etc).
C.Yearly maintenance
1. Check the flexibility of the gears. Replace those that can’t
function well.
2. Check if the spring pieces are out of shape. Replace those with
distortions.
3. Check if the screws on the electrical vortex sensors are
tightened and if the direct current
voltage between “O UT+” and “COM-” is between -1 and -2.
4. Check the fan in the electric equipment cabinet. Check the
voltage of every electric circuit.
5. Check air out line of the air connector.