1. Principle


The test kit is based on the competitive enzyme immunoassay for the detection of Phenylethanolamine A in the sample. The conjugated antigen is pre-coated on the micro-well stripes. The Phenylethanolamine A in the sample and the coupling antigens pre-coated on the micro-well stripes compete for anti- Phenylethanolamine A antibodies. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the sample has a negative correlation with the Phenylethanolamine A concentration in the sample. The value is compared to the standard curve and the Phenylethanolamine A concentration is subsequently obtained.

 

2. Technical specifications


Sensitivity: 0.1 ppb
Incubator temperature: 25℃
Incubator time: 30min~15min


Detection limit
Tissue 0.2 ppb
Feed 0.5 ppb


Cross-reactions:
Phenylethanolamine A 100%
Ractopamine <1%
Salbutamol <1%
Clenbuterol <1%
Recovery rate
Tissue, feed 85±25%

 

3. Components

 

1Micro-well strips

12 strips with 8 removable

wells each

26× standard solution (1mL each)0ppb0.1ppb
0.3ppb0.9ppb
2.7ppb8.1ppb
3Enzyme conjugate7mlred cap
4Antibody working solution7mlblue cap
5Substrate A7mlwhite cap
6SubstrateB7mlblack cap
7Stop solution7mlyellow cap
820× concentrated washing buffer40mlwhite cap
92× concentrated redissolving solution50mltransparent cap

 

4. Materials required but not provided


1) Equipments:microplate reader, printer, homogenizer, nitrogen-drying device, oscillator, centrifuge, measuring pipets, balance ( a reciprocal sensibility of 0.01 g), incubator.
2) Micropipettors: single-channel 20-200 µL and 100-1000 µL, and multi-channel 30-300 µL;
3) Reagents: Ethyl acetate, N-hexane, Glacial acetic acid

 

5. Sample pre-treatment


Instructions(The following points must be dealt with before the pre-treatment )
1) Only the disposable tips can be used for the experiments and the tips must be changed when used for absorbing different reagents;
2) Before the experiment, each experimental utensil must be clean and should be re-cleaned if necessary, in order to avoid the contamination that interferes with the experimental results.


Solution preparation before sample pre-treatment:
1) Sample extracting solution: take 99ml ethyl acetate, add 1 ml glacial acetic acid, and mix it well.
2) Sample redissolving solution: the 2×concentrated redissolving solution is diluted with deionized water at 1:1(1mL concentrated redissolving solution + 1mL deionized water), used for sample redissolving.


Samples preparation
5.1 Feed
1. Grind sample, take 1.0±0.05g into a 50ml centrifuge tube;
2. Add 10 mL Sample extracting solution, shake with oscillator for 3 min;
3. Centrifuge at 4000 r/min at room temperature for 10 min;
4. Take 2 ml supernatant, blow to dry with nitrogen or air at 50-60 ℃;
5. Add 1 ml N-hexane, then add 1ml Sample redissolving solution, shake for 30s;
6. Centrifuge at 4000 r/min at room temperature for 10 min, remove the up-layer organic phase.
7. Take 20 µL down-layer for analysis.
Fold of dilution of sample:5
(Because there is sample disturbance, recommend2PPB as sample CUT OFF value. )


5.2 Tissue
1.Take homogeneous tissue sample 2.0±0.05g into a 50ml centrifuge tube;
2.Add 8 mL Sample extracting solution, shake with oscillator for 2 min;
3.Centrifuge at 4000 r/min at room temperature for 10 min;
4.Take 2 ml supernatant, blow to dry with nitrogen or air at 50-60℃;
5.Add 1 ml N-hexane, then add 1ml Sample redissolving solution, shake for 30s;
6.Centrifuge at 4000 r/min at room temperature for 10 min, remove the up-layer organic phase.
7.Take 20 µL down-layer for analysis.
Fold of dilution of sample:2
(Because there is sample disturbance, recommend1PPB as sample CUT OFF value. )

 

6. ELISA procedures


6.1Instructions
1. Bring all reagents and micro-well strips to the room temperature (20-25 ℃) before use.
2. Return all reagents to 2-8 ℃ immediately after use.
3. The reproducibility of the ELISA analysis, to a large degree, depends on the consistency of plate washing. The correct operation of plate washing is the key points in the procedures of ELISA.
4. For the incubation at constant temperatures, all the samples and reagents must avoid light exposure, and each microplate should be sealed by the cover membrane.


6.2Operation procedures
1. Bring test kit to the room temperature (20-25 ℃) for at least 30 min, note that each liquid reagent must be shaken to mix evenly before use.
2. Solution preparation: Dilute the 40ml 20× concentrated washing buffer with deionized water at 1:19 (1 part 20× concentrated washing buffer + 19 parts deionized water), or prepare as quantity needed.
3. Put the required micro-well strips into plate frames. Re-sealed the unused microplate, stored at 2-8 ℃, not frozen.
4. Numbering: number the micro-wells according to samples and standard solution; each sample and standard solution should be performed in duplicate; record their positions.
5. Add 50 µL of the sample or the standard solution into separate duplicate wells; add 50 µL of enzyme conjugate, then add 50 µL of the antibody working solution into each well, seal the microplate with the cover membrane, andincubate at 25 ℃ for 30 min.
6. Pour liquid out of microwell, flap to dry on absorbent paper; add 250 µL/well of deionized water, wash for 15-30 seconds, then take out and flap to dry with absorbent paper, repeat 4-5 times.
7. Coloration: add 50 µL of the substrate A solution, 50 µL of the B solution into each well. Mix gently by shaking the plate manually, and incubate at 25 ℃ for15 min at dark for coloration.
8. Determination: add 50 µL of the stop solution into each well. Mix gently by shaking the plate manually. Set the wavelength of the microplate reader at 450 nm to determine the OD value of every well. (Recommend to read the OD value at the dual-wavelength 450/630 nm within 5 min).

 

7. Result judgment


There are two methods to judge the results; the first one is the rough judgment, while the second is the quantitative determination. Note that the OD value of the sample has a negative correlation with the Phenylethanolamine A in the sample.


7.1 Qualitative determination
The concentration range (ng/mL) can be obtained form comparing the average OD value of the sample with that of the standard solution. Assuming that the OD value of the sampleⅠ is 0.3, and that of the sampleⅡ is 1.0, the OD value of standard solutions is: 2.243 for 0ppb, 1.866 for 0.1ppb, 1.415 for 0.3ppb, 0.864 for 0.9ppb, 0.413 for 2.7ppb, 0.155 for 8.1ppb, accordingly the concentration range of the sampleⅠ is 0.3 to 0.9ppb, and that of the sampleⅡ is 2.7ppb to 8.1ppb.


7.2 Quantitative determination
The mean values of the absorbance values obtained for the average OD value (B) of the sample and the standard solution divided by the OD value (B0) of the first standard solution (0 standard) and subsequently multiplied by 100%, that is

 

Percentage of absorbance value =B×100%
B0

 

B—the average OD value of the sample or the standard solution
B0—the average OD value of the 0 ng/mL standard solution
Draw the standard curve with the absorption percentages of the standard solutions and the semilogarithm values of the Phenylethanolamine A standard solutions (ng/mL) as Y- and X-axis, respectively. Read the corresponding concentration of the sample from the standard curve by incorporating its absorption percentage into the standard curve. The resulting value is subsequently multiplied by the corresponding dilution fold, finally obtaining the actual concentration of Phenylethanolamine A in the sample.
Using the professional analyzing software of this kit will be more convenient for the accurate and rapid analysis of a large amount of samples. (Please contact us for this software)


8. Precautions


1. The room temperature below 25 ℃ or the temperature of the reagents and the samples being not returned to the room temperature (20-25 ℃) will lead to a lower standard OD value.
2. Dryness of the microplate in the washing process will be accompanied by the situations including the non-linear standard curves and the undesirable reproducibility; So continue to next step immediately after washing.
3. Mix evenly, wash plate completely, the reproducibility of the ELISA analysis, to a large degree, depends on the consistency of plate washing.
4. The stop solution is the 2 M sulfuric acid solution, avoid contacting with skin.
5. Do not use the kit exceeding its expiry date. The use of diluted or adulterated reagents from the kits will lead to the changes in the sensitivity and the detecting OD values. Do not exchange the reagents from the kits of different lot numbers to use.
6. Put the unused microplate into an auto-sealing bag to re-seal it. The standard substance and the colourless color former is light sensitive, and thus they cannot be directly exposed to the light.
7. Discard the colouration solution with any color that indicates the degeneration of this solution. The detecting value of the 0 standard solutin of less than 0.5 (A450 nm< 0.5 ) indicates its degeneration.
8. The optimum reaction temperature is 25 ℃, and too high or low temperatures will result in the changes in the detecting sensitivity and OD values.


9. Storage and expiry date


Storage: store at 2-8 ℃, not frozen.
Expiry date: 12 months; date of production is on box.
Note: If the Vacuum package of microplate has leakage, it is still valid to use, do not affect the test result, be relax to use.

 

 

 

 

 

Q1: When will it be shipped?
A1: We will ship the goods for you as soon as possible within 7 working days after receiving the payment. (In case of external factors such as the epidemic, the delivery may be delayed)

 

Q2: Does it support OEM/ODM?
A2: It can be supported, but the specific quantity needs to be more than 100,000 pieces, which is convenient for customized products.

 

Q3: How is your factory doing in terms of quality control?
A3: We have nationally certified ISO9001 and ISO13485. Our production process conforms to standard procedures to ensure optimum product quality.

 

Q4: How to provide after-sales service?
A4: We provide professional online technical after-sales service. We can provide you with one-on-one guidance via video, telephone, etc.

 

Q5: What is the payment method?
A5: We receive payment by T/T.

 

Q6: How to ship?
A6: Choose the best shipping method for you by getting quotes from our many cooperative carriers, and also ship according to your requirements.

Hot Products

Nitrofuran AOZ Diagnostic ELISA Kit for Fish 96 Wells/Kit Sensitivity 0.01 1. Nitrofuran AOZ ...
Melamine Diagnostic ELISA Kit for Fresh Milk 96 Wells/Kit Sensitivity 0.5 1. Melamine Diagnostic ...
Deoxynivalenol Diagnostic ELISA Kit for Feed 96 Wells/Kit Sensitivity 2ppb 1. Deoxynivalenol ...
Beta Agonist ELISA Kit For Milk Egg Urine Serum Chicken Pork 96 Wells/Kit 1. Principle The β...
Phenylethanolamine A ELISA Test Kit For Milk Egg Urine Serum Feed 96 Wells/Kit 1. Principle The test ...
Diethylstilbestrol ELISA Test Kit For Milk Egg Urine Serum Feed 96 Wells/Kit 1. Principle This test ...