Chengdu Ample Import And Export Co., Ltd. |
|
1. Product Description
A fume hood (sometimes called a fume cupboard or fume closet) is a
type of local ventilation device that is designed to limit exposure
to hazardous or toxic fumes, vapors or dusts.
A fume hood is typically a large piece of equipment enclosing five
sides of a work area, the bottom of which is most commonly located
at a standing work height.
Two main types exist, ducted and recirculating (ductless). The
principle is the same for both types: air is drawn in from the
front (open) side of the cabinet, and either expelled outside the
building or made safe through filtration and fed back into the
room. This is used to:
-protect the user from inhaling toxic gases (fume hoods, biosafety
cabinets, glove boxes)
-protect the product or experiment (biosafety cabinets, glove boxes)
-protect the environment (recirculating fume hoods, certain
biosafety cabinets, and any other type when fitted with appropriate
filters in the exhaust airstream)
Secondary functions of these devices may include explosion
protection, spill containment, and other functions necessary to the
work being done within the device.
2. Product Parameters
Model Parameters | YT-1500A | YT-1500B | YT-1500C | YT-1800A | YT-1800B | YT-1800C |
Size (mm) | 1500(W)*865(D)*2400(H) | 1800(W)*1205(D)*2400(H) | ||||
Worktop Size (mm) | 1260(W1)*795(D1)*1100(H1) | 1560(W1)*795(D1)*1100(H1) | ||||
Worktop | 20+6mm Ceramic | 20+6mm Ceramic | 12.7mm Solid Physiochemical Board | 20+6mm Ceramic | 20+6mm Ceramic | 12.7mm Solid Physiochemical Board |
Liner | 5mm Ceramic Fibre | 5mm Compact Laminate | 5mm Compact Laminate | 5mm Ceramic Fibre | 5mm Compact Laminate | 5mm Compact Laminate |
Diversion Structure | Back Absorption | |||||
Control System | Touch-Tone Control Panel (LED Screen) | |||||
Input Power | 220V/32A | |||||
Fan Power | Less than 2.8 A | |||||
Socket Max. Load | 5KW | |||||
Faucet | 1 Set | |||||
Drainage Mode | Natural Fall | |||||
Storage | Double-Lock, Corrosion-Resistant, Damp-proof, Multi-layer Solid Wood with Mobile Wheel | |||||
Application | Indoor No-blast, 0-40 ℃ | |||||
Application Field | Organic Chemical Experiment | |||||
Face Velocity Control | Manual Control | |||||
Average Face Velocity | 0.3-0.5 m/s Exhaust: 720-1200m³/h | 0.3-0.5 m/s Exhaust:900- 1490m³/h | ||||
Face Velocity Deviation | Less than 10% | |||||
Average Illumination | Less than 500 Lux | |||||
Noise | Within 55 dB | |||||
Exhaust Air | No Residue | |||||
Safety Test | In Accord with International Standard | |||||
Resistance | Less than 70Pa | |||||
Add Air Function | Distinctive Structure (Need Exclusive Add Air System) | |||||
Air Flow Control Valve | Dia. 250mm Flange Type Anti-Corrosion Control Valve | Dia. 315mm Flange Type Anti-Corrosion Control Valve |
3. More About the Fume Hood
Choosing The Right Liner Material For A Fume Hood
A major consideration for fume hoods is the material of
construction, specifically the liner material. There are many liner
types that are used for various applications and the liner must be
compatible with the chemicals being used. Selecting the right liner
will make all the difference and play a major role in the longevity
of your fume hood.
Polyvinylchloride (PVC)
Also known as poly or vinyl, this widely produced synthetic plastic
polymer is chemically resistant to acids, salts, bases, fats, and
alcohols. Typical applications involve acid digestions with
chemicals like perchloric, hydrofluoric, sulfuric, and nitric
acids. This material is also commonly found in wash down stations.
It has moderate resistance to heat and moderate structural
strength.
Fiberglass Reinforced Composite Panel
A fiberglass reinforced composite panel liner is the most common
fume hood liner. This inexpensive liner material offers high
chemical resistance coupled with low smoke and flame toxicity
properties. It also provides great temperature control, durability,
moisture resistance, and structural strength.
Molded Fiberglass Reinforced Polyester
The molded fiberglass reinforced polyester offers a sleek,
one-piece liner. It is corrosion and fire-resistant and makes for
easy cleanup. Due to no internal seams, the interior has no cracks
where contaminants can collect leading to fewer points of
deterioration and longer life expectancy. The high light
reflectivity surface is designed to withstand exposure to a wide
range of acids, solvents, and alkalis.
4. Detailed Photos
5. Fume Hood Maintenance
• Hoods should be evaluated by the user before each use to ensure adequate face velocities and the absence of excessive turbulence.
• In case of exhaust system failure while using a hood, shut off
all services and accessories and lower the sash completely. Leave
the area immediately.
• Fume hoods should be certified, at least annually, to ensure they
are operating safely. Typical tests include face velocity
measurements, smoke tests and tracer gas containment. Tracer gas
containment tests are especially crucial, as studies have shown
that face velocity is not a good predictor of fume hood leakage.
• Laboratory fume hoods are one of the most important used and
abused hazard control devices. We should understand that the
combined use of safety glasses, protective gloves, laboratory
smocks, good safety practices, and laboratory fume hoods are very important elements in protecting us from a potentially hazardous
exposure.
• Laboratory fume hoods only protect users when they are used
properly and are working correctly. A fume hood is designed to
protect the user and room occupants from exposure to vapors,
aerosols, toxic materials, odorous, and other harmful substances. A
secondary purpose is to serve as a protective shield when working
with potentially explosive or highly reactive materials. This is
accomplished by lowering the hood sash.
6. Project Cases