Home Companies Chengdu Ample Import And Export Co., Ltd.

Corrosion Resistance Chemical Ductless Fume Hood For School

Chengdu Ample Import And Export Co., Ltd.
Active Member

Contact Us

[China] country

Address: T2-715, Landmark Plaza, High-Tech Zone, Chengdu, China

Contact name:Mike Ma

Inquir Now

Chengdu Ample Import And Export Co., Ltd.

Corrosion Resistance Chemical Ductless Fume Hood For School

Country/Region china
City & Province chengdu
InquireNow

Product Details

Corrosion Resistance Chemical Ductless Fume Hood For School

Product Description


Probably the most important consideration is the type of chemicals that your laboratory uses. The majority of ductless fume cabinets are only suitable for process-specific or light-duty fumes. Before you decide if this unit is right for you, compile a list of all the chemicals and the quantities of each. From this, you should be able to determine if a ductless hood would work in your lab. If your laboratory use is likely to change over time, or you do not know what type of chemicals will be used in future, then this fume extraction system might not be the best choice for you. The safety and health of your employees or operators should be your top priority, so the type of chemicals you are using will be the main deciding factor on whether a ductless fume hood is right for you.

Another critical factor to consider is the cost of a recirculating fume hood. We have already mentioned that this system can often be more cost-effective than a ducted alternative. A ducted system needs to have an expensive infrastructure around it, such as ducting, mechanical systems, exhaust fans, roof elements and more. All of these things are an additional cost to consider. A filtered hood eliminates all of these extra costs, but that does not mean they are free to run. Ductless hoods will need regular filter replacements, which is an expenditure that needs to be taken into account.

Product Parameters

 

                Model Specification  WJ-1500AWJ-1500BWJ-1800AWJ-1800B
External dimensions of equipment(mm)1500(W)*1205 (D) *2400 (H)1800(W)*1205 (D) *2400 (H)
Dimension of works pace (mm)1260(W1)*780(D1) *1100 (H1)1560(W1)*780(D1) *1100 (H1)
Panel material20+6mm thick butterfly ceramics
Material of internal lining board5mm thick ceramic fiber board
Diversion structureLower air return
Control systemButton control panel (LCD panel)
PH value controlThe medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
Input powerThree-phase five-wire 380V/50A
Current for air fanNot over 2.8A(380V or 220V can be directly connected)
Maximum load of socket12 KW(total of 4 sockets)
Water tap1 set (remote control valve + water nozzle)No1 set (remote control valve + water nozzle)No
Water discharge wayMagnetic chemical pump strong discharge
Using environmentFor non-explosion indoor use, within 0-40 degrees Celsius.
Applicable fieldsInorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
Ways of PurificationSpray sodium hydroxide solution, no less than 8 cubic meters/hourSpray sodium hydroxide solution.no less than 12 cubic meters/ hour
Ways of surface air speed controlManual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
Average surface air speed0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm)0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
Speed deviation of surface airNot higher than 10%
The average intensity of illuminationNot less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
NoiseWithin 55 decibels
Flow displayWhite smoke can pass through the exhaust outlet, no overflow.
Safety inspectionNo spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
Resistance of exhaust cabinetLess than 160 pa
Power consumptionLess than 1.0kw/h (excluding power consumption of fans and external instruments)Less than 1.2kw/h (excluding power consumption of fans and external instruments)
Water consumptionLess than 3.2L/ hLess than 4.0L/ h
Performance of wind compensationWith a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
Air volume regulating valve315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)
 
Common Applications


Ductless fume hoods are used in various fields. Some of the most common applications are the following:

  • Life Sciences
  • Forensics, Fingerprinting and DNA
  • Educational Purposes
  • Clinics and Hospitals
  • Dental Laboratory
  • Cleanrooms
  • 3D Printing
  • Archaeology
  • Glass Manufacturing
  • Mycology
  • Soldering
  • Pharmaceutical
  • Art Restoration
  • Production of Glues, Paints, and Solvents
Detailed Photos
      
Corrosion Resistance Chemical Ductless Fume Hood for School
Corrosion Resistance Chemical Ductless Fume Hood for School
 
Corrosion Resistance Chemical Ductless Fume Hood for School
Corrosion Resistance Chemical Ductless Fume Hood for School
 
Application Cases

Choosing the right fume hood for your laboratory can be a challenge, and ductless fume hoods could be the solution you have been looking for. Whether you are working in an educational laboratory or an industrial location, having the right fume hood at your disposal is crucial. This piece of equipment is so important for the safety of your lab and your team, so choosing the right one is vital.

Also known as a recirculating fume enclosure or a filtered fume hood, a ductless unit is self-contained and works to remove toxic molecules, particles and vapour from the air. Having a chemical fume cabinet is likely to be the most essential piece of safety equipment your workplace can have. They clean the contaminated air to deliver clean air back into the environment. Compared with other types of chemical fume hoods, the ductless solutions can be more cost-efficient, easier to install and don't require ductwork around the building. Despite all these benefits, ductless fume hoods are not suitable for every situation. There are a few factors that you need to take into account before deciding if a this type of fume cupboard is suitable for your laboratory.

Corrosion Resistance Chemical Ductless Fume Hood for School
Corrosion Resistance Chemical Ductless Fume Hood for School

 

Hot Products

Acid & Alkali Resistant Heat Resistant Fireproof Explosion Proof Chemical Laboratory Fume Hood 1. ...
Acid And Alkali Resistant Chemical Ductless Fume Hood For School Product Description The ductless ...
Corrosion Resistance Chemical Ductless Fume Hood For School Product Description Probably the most ...
380V Water Spraying Laboratory Fume Hood Recirculating Air Flow Water Spray Laboratory Fume Hood Air ...
Acid & Alkali Resistant Fireproof Explosion Proof Chemical Lab Duct Fume Hood Heat Resistant 1. ...
Multi-Layer Solid Wood Duct Chemical Fume Hood Corrosion Resistant 1. Product Description A fume ...