AMAXPOWER NEW ENERGY TECH CO., LTD |
|
Amaxpower Deep Cycle Gel Rechargeable Storage Battery for Solar Panel/Inverter/Power-Tool/UPS/Electric-Scooter (12V 65Ah)
Amaxpower battery 12V65Ah Rechargeable Gel Deep Cycle Storage Battery For Aerial Work Platform and Solar System
AMaxpower sealed free maintenance AGM and GEL storage batteries. Our batteries are always in the process of innovation according to market and environment: AGM battery→GEL battery→High Temperature Long Life Deep Cycle GEL battery.
Key Features :
* 12v 65ah rechargeable vrla ups battery
* Gelled electrolyte made by mixing sulfuric acid with silica fume
* The electrolyte is gel like ,immobile and does not leak
,enabling uniform reaction of each part of the plate .
* High rate discharge performance due to tight assembly
technology
* Strong heat dissipation and wide operating temperature range
* Avoid acid mist being separated out , environment
friendliness
* Efficient venting system release excessive gas automatically
Amaxpower Deep Cycle Gel Battery is Best Partnar for :
* Solar and wind energy storage system
* EPS and UPS battery backup
* Signal system , emergency lighting system , security system
* Telecommunication Equipment
* Power plant and transmission system
Specification
Nominal Voltage | 12V (6 cells) | |
Nominal Capacity | 65Ah@10 hour-rate | |
Dimension | Length | 350±2(13.8 inches) |
Width | 166±2(6.54 inches) | |
Height | 179±2(7.05 inches) | |
Total Height | 179±2(7.05 inches) | |
Weight | Approx. 19kg (41.9lbs) | |
Reference Capacity (25°C/77°F ) | 20 hour rate (3.41A) | 68.2Ah |
10 hour rate (6.5A) | 65Ah | |
5 hour rate (11.7A) | 58.5Ah | |
3 hour rate (17.3A) | 52Ah | |
1 hour rate (42.2A) | 42.2Ah | |
Max. Discharge Current (25°C/77°F) | 422A (5S) | |
Internal Resistance | Full charged at 25℃(77°F): Approx. 8.0mΩ | |
Charge (Constant Voltage) (25°C/77°F) | Cycle Use | Voltage: 14.4-15.0V Initial Charging Current: Less than 16.3A |
Float Use | Voltage: 13.6-13.8V | |
Operating Temperature Range | Discharge | -20~50°C |
Charge | 0~50°C | |
Storage | -20~50°C | |
Nominal Operating Temperature Range | 25°C ±3°C(77±3°F) | |
Capacity affected by Temperature (20 hour rate) | 40°C(104°F) | 102% |
25°C(77°F) | 100% | |
0°C(32°F) | 85% | |
-15°C(5°F) | 65% | |
Self-Discharge (25°C/77°F) | After 3 month | 91% |
After 6 month | 82% | |
After 12 month | 64% | |
Container Material | ABS Plastic |
-Solar energy system -Aerial work platform
-Floor cleaning machine -Recreational vehicles
-Golf cart and Buggies -Control System
-Power Tools -UPS Systems
-Solar and Wind -Emergency Systems