Features of Ultra Low Temperature Two Stage Water Heating Air Source Heat Pump
An air energy water heater, comprising a heat exchanger, a water
pump and a water tank, characterized in that the water tank
comprises a high-temperature heat storage liner and a
low-temperature circulating liner respectively connected with the
heat exchanger, which are heated by the heat exchanger The latter
water below the set temperature enters the low-temperature
circulation liner and then enters the heat exchanger for cyclic
heating until it reaches the set temperature and then enters the
high-temperature heat storage liner for use. Ensure the stability
of the outlet water temperature, realize that there will be no
water mixing problems during defrosting and water replenishment;
and can reduce the volume, reduce the requirements for installation
space, and increase the scope of application.
It includes an ultra-low temperature air energy hot fan body. Two
square rods are symmetrically arranged on the outer side of the
ultra-low temperature air energy hot fan body. Both ends of the
square rods are fixed with connecting plates, and the connecting
plates are fixed to the ultra-low temperature air energy hot fan
body. The connecting plate is sleeved with two sliders, the upper
end surface of the slider is provided with a foot hole, the upper
end surface of the slider is provided with a first round hole on
the side away from the foot hole, the square The upper end surface
of the rod is equidistantly provided with a plurality of threaded
through holes that are matched with the first circular hole, and
the first circular hole is provided with a first connecting bolt,
and the first connecting bolt passes through the first circular
hole to engage with the thread In the through hole, compared with
the prior art, the utility model has the following beneficial
effects: the convenient adjustment of the fixed position is
realized, and the position of the ultra-low temperature air energy
hot air blower does not need to be adjusted as a whole
Some specifications of Ultra Low Temperature Two Stage Water Heating Air Source Heat Pump
Spec. | DKFXRS-9I/CY | DKFXRS-11I/CY | DKFXRS-11II/CY | DKFXRS-16I/CY | DKFXRS-16II/CY | DKFXRS-19II/CY | DKFXRS-38II/CY |
Nominal heating at room temperature・(kW) | 9.6 | 10.9 | 10.8 | 16 | 16.4 | 17.4 | 38.9 |
Nominal power consumption at room temperature(kW〕 | 2.17 | 2.63 | 2.7 | 3.9 | 4.1 | 4.6 | 8.82 |
Low temperature heating(kW) | 4.1 | 4.65 | 4.8 | 7.8 | 7.5 | 8.5 | 17.6 |
Low temperature power consumption(kW) | 1.85 | 2.1 | 2.16 | 3.37 | 3.4 | 3.68 | 7.3 |
Maximum input power(kW) | 3 | 4.2 | 4.2 | 6.6 | 6.8 | 8.5 | 17 |
Maximum current(A) | 16 | 23 | 8A | 32 | 12 | 15 | 30 |
Power Spec.(Hz) | 220V-50 | 220V-50 | 380V3N-50 | 220V-50 | 380V 3N-50 | 380V3N-50 | 380V 3N-50 |
Refrigerant/charge amount | R22/2500g | R22/5600g | R22/5600g | R22/6000g | R22/6000g | R22/6500g | R22/6500gx2 |
noisedb(A) | <55 | <62 | <62 | <65 | <65 | <66 | <68 |
Water resistancekPa | <55 | <55 | <55 | <100 | £100 | <65 | <65 |
Anti-shock level | I | I | I | I | I | I | I |
waterproof level | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 |
Circulation port diameter | DN20 | DN32 | DN32 | DN32 | DN32 | DN32 | DN40 |
Unit size (mm) | 1010x350x835 | 1030x410x1390 | 1030x410x1390 | 1030x410x1390 | 1030x410x1390 | 780x820x1700 | 1550x780x1700 |
Unit Weight(kg) | 87 | 142 | 142 | 148 | 149 | 265 | 435 |
Some projects of Ultra Low Temperature Two Stage Water Heating Air Source Heat Pump