Henan Lantian Medical Supplies Co.,Ltd. |
|
The disposable vacuum blood collection container consists of a test
tube, a plug, a cap, a label, additives (if any) and additives (if
any).
Sodium citrate 9:1, Sodium citrate 4:1, Heparin sodium, Liheparin opening, Liheparin Lin/separation glue coagulation/separation glue, curing accelerator, EDTAK2 heparin sodium/sodium fluoride, EDTAK2 / separation adhesive, EDTAK3 EDTAK3 / separation adhesive, Heparin sodium/separation adhesive, no addition
Used in conjunction with disposable intravenous needles for the
collection, transportation and preservation of human venous blood.
1.Red blood collection vessel -- common / rapid serum tube
There is no anticoagulant, also known as biochemical tube. The
inner wall of the blood collecting vessel is evenly coated with
agents to prevent wall hanging. It is mainly used for blood
biochemistry. It is divided into ordinary serum tube and rapid
serum tube. The label will indicate whether there is coagulant or
not, or use red and orange to distinguish the two. The function of
coagulant is to accelerate blood coagulation. If you want to clot
quickly, you can use the procoagulant tube.
Sample type: Serum
Uses: tumor, gonad, immune routine, immunization, rheumatoid
antibody, diabetic nephropathy detection, blood three items, ICA
(insulin cell antibody), GAD (glutamic acid decarboxylase
antibody), ABAP (bone type alkaline phosphatase), prostaglandin
(T-PSA-F-PSA), HBV-DNA, ferritin, condensation set, procalcitonin
PCT, mycoplasma antibody, gastrin, ANCA, CMV antibody, human
epididymal epithelial secretory protein, serum protein
electrophoresis, RA, tb-ad, TB antibody.
2.Green blood collecting vessel heparin anticoagulant tube
Heparin is added to the blood collection vessel. Heparin directly
has the effect of antithrombin, which can prolong the clotting time
of the specimen. Excessive heparin will cause the aggregation of
leukocytes, and can not be used for leukocyte count. Because it can
make the background of blood stained light blue, it is not suitable
for leukocyte classification.
Sample type: whole blood, plasma
Purpose: erythrocyte fragility test, blood gas analysis, hematocrit
test, erythrocyte sedimentation rate and biochemical determination.
3.Light green blood collecting vessel plasma separating tube
Heparin containing lithium or heparin sodium and gel, heparin is a
kind of mucopolysaccharide containing sulfuric acid group, with a
strong negative charge, has enhanced the antithrombin 3
inactivation of serine protease, thereby preventing thrombin
formation, and has prevented platelet aggregation and other
anticoagulant effects. Under normal circumstances, 15IU heparin
anticoagulant 1ml blood. Heparin tube is generally used for
emergency biochemical and hemorheological tests.
Sample type: plasma
Uses: TNT, EPM, B27, blood ammonia, BNP (B-type natriuretic
peptide)
4.Deep blue blood collection vessel trace element tube
It contains heparin sodium, EDTA Na2, EDTA K2, coagulant (plastic
tube, serum) and additive without coagulant (glass tube, serum).
Heparin sodium should not be used in the detection of sodium ion in
blood samples, so as not to affect the detection results.
Purpose: trace element, toxicology and nutritional chemistry test
5.Purple blood collection -- EDTA anticoagulant
It contains EDTA anticoagulant. Compared with other anticoagulants,
EDTA anticoagulant has less effect on hemagglutination and
morphology of blood cells, so EDTA salt (2k, 3k, 2Na) is usually
used as anticoagulant. EDTA salt can combine with calcium ion in
blood to form chelate, so as to prevent blood coagulation.
Sample type: whole blood, plasma
Application:
2ml: blood routine, reticulocyte, HBAIC, TC, BNP
5ml: pituitary, parathyroid hormone, renin, adrenal function,
adrenocortical function, atch + COR, cortisol (COR), blood group +
D antigen (syncytial blood)
It is not suitable for coagulation test and platelet function test,
nor for determination of calcium, potassium, sodium, iron, alkaline
phosphatase, creatine kinase, leucine aminopeptidase and PCR test.
6.Golden yellow blood collecting vessel -- Inert separation and
coagulation promoting tube
It contains inert separation gel and coagulant. The coagulant on
the tube wall can accelerate the coagulation of blood, avoid 37 ℃
water bath and shorten the test time. The separation gel has good
affinity with pet tube, and plays an isolation role.
Specimen type: Serum
Application:
3ml: biochemical items, digoxin concentration, myocardial enzyme,
amylase, thyroid function, total thyroid function, free thyroid
function, total thyroid hormone determination, thyroid antibody,
thyroid receptor antibody
5ml: C-reactive protein (CRP), high sensitivity C-reactive protein
(hs CRP)
7.Light blue blood collecting vessel sodium citrate blood
collecting vessel
It contains 3.2% or 3.8% sodium citrate. When taking blood, please
pay attention to take enough blood to ensure the accuracy of test
results. After blood collection, please reverse immediately and mix
well for 5-8 times. The ratio of anticoagulant to blood was 1:9
Type of specimen: whole blood, plasma
Purpose: for fibrinolysis system (prothrombin time, thrombin time,
activated partial thromboplastin time, fibrinogen).
8.Black blood collection vessel -- sodium citrate ESR test tube
It contains 3.2% (0.109 mol / L) - 3.8% sodium citrate. The volume
ratio of anticoagulant to blood is 1:4. When the anticoagulant
ratio is too high, the blood will be diluted and the ESR will be
accelerated. Heparin anticoagulant can change the potential of red
blood cells, so it is not suitable for the detection of erythrocyte
sedimentation rate.
Sample type: whole blood
Application: ESR
9.Gray blood collection vessel -- sodium oxalate / sodium fluoride
blood glucose test tube
The additive in the tube is sodium fluoride + potassium oxalate /
sodium fluoride + heparin sodium. Sodium fluoride is a weak
anticoagulant, which has a good effect in preventing the
degradation of blood glucose. 4mg of the mixture of sodium fluoride
+ potassium oxalate / sodium fluoride + heparin sodium can make 1ml
blood not coagulate and inhibit the decomposition of sugar in 23
days. Please pay attention to slowly reverse and mix well when
using it.
Purpose: blood glucose detection, can not be used for urea Urease
method, also can not be used for alkaline phosphatase and amylase
determination.
Store in a dry, well-ventilated and clean room with no corrosive
gas and relative humidity above 80%
1.According to different test requirements, select the appropriate
blood collection vessel. If you have any questions, please contact
the staff of the laboratory at any time.
2.The sample number must be pasted on the blood collection vessel,
which is consistent with the number on the inspection sheet. It
should be pasted on the paper label of blood collection vessel, not
on the glass to prevent falling off.
3. When taking blood, patients should be relaxed, warm environment,
prevent venous contracture, tie tourniquet time should not be too
long (now some scholars think that try not to use tourniquet),
observe whether the blood collection is smooth, forbid to pat the
arm, otherwise it may cause local blood concentration or activate
the coagulation system.
4. The recommended order of blood collection is no anticoagulant
tube (serum tube) → separation gel / accelerator tube → heparin /
EDTA tube → coagulation vessel → blood sedimentation tube. The main
reason is that the first tube often contains tissue fluid, which is
easy to cause coagulation and is not suitable for hemagglutination
test; Furthermore, to avoid the contamination of serum tube by
anticoagulant.
5. After blood collection, the blood samples shall be rolled
according to different test categories (biochemical, immune,
routine, coagulation, ESR) with test sheets, and classified. All
blood samples shall not be mixed together, so as to avoid confusion
in operation.
6.The proportion of blood and anticoagulant must be accurate, and
the blood volume should meet the requirements.
7 after blood collection, gently turn the test tube and mix 8-10
times, but do not vibrate violently. The sample should be placed
vertically after blood collection.