 Copper Dry Cooler Oil Water copper Cooler industrial copper tube cooler​ 

Dry cooler is similar to an air cooled condensing unit, but utilizes a liquid solution, such as water, Ethylene Glycol/Water, or Propylene Glycol/Water, to transfer heat in lieu of refrigerant and compressors. These systems are often seen in Data Centers where excess heat needs to be removed, but certain low levels of humidity are not required. The water or solution absorbs heat from the space and transfers it outside to the dry cooler, which uses a series of condensing fans to perform its cooling.

 

A significant benefit of this type of system is that no liquid evaporation takes place, which eliminates the need for make-up water. Dry coolers can often reject larger amounts of heat in a much smaller footprint than traditional direct expansion air cooled condensing units, which can be a benefit for projects with limited ground or roof space.

 

Application :

  • Data centers
  • Office buildings
  • Hospitals/medical office buildings
  • Industrial/process systems
  • Heat transfer/recuperation
  • Power generation
  • Induction cooling

 

Quality Details


Selection Data

OEM Customation 

Frame

Fin

Heat-exchange Tube

Fan

Electric Control

Other

Hot dip galvanized steel

Hydrophilic Fin

Stainless steel 304

EC Fan

Junction Box

HT/LT Double-Bank Heat-exchange

Stainless steel 304

Almg 25

Stainless steel 316

Explosion-proof fan motors

safety Switch

Adiabatic Water spraying system

Stainless steel 316

Copper Fin

B10

Marine Fan Motor

Control Box

Steel Structure and safe access for service

Aluminum

Pre-coated Epoxy Fin

B30

Stainless Steel Guards

VFD Control Box

Air filter

 

Copper Tinned Fin

Titanium

 

Temperature/Pressure Control Box

 

 

Heresite/ Blygold/Epxoy Coated Fin

 

 

 

 

 

 

  Advantages  

Design softwareUsing the mature European design software, according to the EN1048 and actual demand accurate design of heat exchanger, can design the special low temperature cold agent etc.
Heat exchange structureSupported to the casing by means of a "flating-bed " system that avoids any kind of contact between the heat-exchange tubes and the supporting end plates,assuring a long life for the heat-exchange without leaks. Heat-exchange sections separated and independent for each fan. The standard fin spacing is 2.1mm,Fin pitch up to 12mm for low air pressure drop.
Condenser structureShape with flexible and changeable,--Flat-bed,W-Bank,V-Bank; Fan direction--blowing and sucking. Finned length up to 12m,Finned height up to 2.7m.
Heat Exchange TubeUsing copper content more than 99.9% pipe,using three type copper tube 3/8",1/2",5/8" Increased the thermal efficiency and low fluid pressure drop .
CasingUsing galvanized sheet case, spraying outdoor powder coatings, and after high temperature curing, high strength of corrosion resistance is strong, the standard color for RAL9003.
FansLow noise axial fans,with maintenance free motors in protection class IP 54,Internal motor protection with thermo contacts.With precise design, forming mould processing, air volume is larger and more efficient.
 

 

 

Project Experience
  • 3D model drawing available
  • Prototype testing and confirmation
  • Steel frame support, Front to Back type design and manufacturing
  • Easy mounting and maintain, Good anti-vibration
  • Stable Performance & Low Pressure Drop
  • Compact Design & Light Weight
  • Motor & Fan is Optional
  • 12 Month Global Warranty
  • OEM Production is Offered

                      

 

Purchasing Guide

 

You just need to tell us your specific requirements and environmental parameters so that we can make professional quotations accordingly.

Please advise:

 

Oil parameterFluid 
Flow 
Inlet temperature (℃) 
Cooling power (kw) 
Max. allowable pressure drop 
Max. work pressure (MPa) 
Air parameterFlow 
Inlet temperature (℃) 
Cooling power (kw) 
Max. allowable pressure drop 
Max. work pressure (MPa) 
Cool air parameterFlow & Pressure curve 
Inlet temperature (℃) 
Air trace 
MountingMax overall dimension 
Location of connections 
Requirement of structure 
Working condition 

 

Be free to contact us if you need any further information, thank you!

Hot Products

V-Bank Dry Cooler Air Condenser for data center office building​ Dry coolers can play a significant ...
Copper Dry Cooler Oil Water copper Cooler industrial copper tube cooler​ Dry cooler is similar to an ...
Customized Automotive oil cooler radiator combined Heat Exchanger Description Our full aluminum ...
Aluminum finned tube heat exchanger for Turbo intercooler aftermarke​ Description ADV is specialized ...
Aluminum Automotive Radiator for motorcycle aftermarket engine cooling Description: High quality ...
Aluminum tube fin Automotive Radiator Core for heavy duty perfrmance Description ADV is specialized ...