Acrel AIM-M200 hospital insulation monitoring device accurate Insulation resistance monitoring prompt alarm relay output

Jiangsu Acrel Electrical Manufacturing Co., LTD.

Contact Us

[China] country

Trade Verify

Address: No. 9 Xincheng Road,Chengjiang Street, Jiangyin City, Jiangsu Province,China

Contact name:Dina Huang

Inquir Now

Jiangsu Acrel Electrical Manufacturing Co., LTD.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Acrel AIM-M200 hospital insulation monitoring device accurate Insulation resistance monitoring prompt alarm relay output

Country/Region china
City & Province jiangsu
Categories Measuring & Analysing Instrument Processing Services
InquireNow

Product Details

General


    The AlM-M200 monitors the insulation resistance of medical IT system, At the same time, the load current and temperature of the IT system transformer are monitored. In combination with ASG100 AIL100series insulation fault locators and the appropriate measuring current transformers, the AlM-M200 is designed to support insulation fault location.

 

Technical parameters

 

ModelAIM-M10AIM-M100AIM-M200
Power supplyVoltageAC220V±10%AC220V±10%DC24V±25%
 Frequency50/60Hz50/60Hz-
 Max power consumption<5W<8W<3W
Insulation monitoringInsulation resistance measuring range10-999kΩ
 Relative percentage accuracy0—±10%
 Alarm value range10—995kΩ50—999kΩ50—999kΩ
 Response time<2s
 Measuring voltage<12V
 Measuring current<42uA<50uA<50uA
Current monitoringMeasuring range2.1-50A
 Alamm value range5-50A
 Measurement accuracy≤±5%
Temperature monitoringThermal resistorPT100
 Measuring range-50—+200℃
 Alarm value range0—+200℃
Alarm outputOutput type1 channel relay output2 channels relay output(programmable)2 channels relay output
 Contact rating

AC 250V/3A

DC 30V/3A

AC 250V/3A

DC 30V/3A

AC 250V/3A DC 30V/3A
EnvironmentWorking temperature-10—+55℃
 Storage temperature-20—+70℃
 Relative humidity5%-95%,non-condensing
 Altitude≤2500m
CommunicationRS485 interface,Modbus-RTU protocolRS485 interface,Modbus-RTU protocol

CAN interface, custom protocol,

RS485 interface, Modbus-RTU protoco

 

 

Display sample of AIM-M200 Hospital Insulation Monitoring DeviceWiring diagram of AIM-M200 Hospital Insulation Monitoring DeviceInsulation measurement LCD displayAMI-M200 monitor load and temperature of insulation transformer LCD display and relay output terminal of AIM-M200 Hospital Insulation Monitoring DeviceKeypads HMI illustrationPractical application of AIM-M200 Hospital Insulation Monitoring Device in hospital IT power supply system