Product Details

Centralised Venting System LR-6-GFM150 VRLA Battery

 

Introduction

The Acme T range of access VRLA batteries has been specifically designed for applications using 19" and 23" cabinets,especially telecoms.Reliability is assured with the patented post seal and a state-of-the-art design developed to comply withthe latest IEC, British and Telcordia standards. A 12+ years design life and centralised venting system add to the suitabilityand flexibility of this superior range.

 

General Specification

Battery Model
LR-6-GFM150
Nominal Voltage
12V
Rated Capacity
15Ah (10 hour rate) to 1.8V/cell@25ºC
Typical Weight
47kg
Internal Resistance
Approx 5.17mΩ
Temperature Ranges
Operation (maximum): -40ºC to 55ºC (-40 oF to 131oF)
Operation (Recommended): 15ºC to 25ºC (29o F to 77oF)
Storage: -20ºC to 40ºC (-4 oF to 104 oF)
Float Voltage
2.25V/cell@25ºC (77oF)
Recommended Maximum Charging Current Limit
37.5A
Equalize and Cycle Service
2.35V/cell@25ºC (77oF)
Self Discharge
The residual capacity is above 91% after 90 days storage (25ºC/77oF)
Terminal
M6 Female
Terminal Hardware Torque
8~10Nm
Container Material
ABS V0 (optional)

 

Constant Current Discharge Characteristics Units: Amperes (25ºC,77oF)
End voltage/cell
5min
15min
30min
45min1h2h3h4h5h6h8h10h12h20h24h
1.60V
420
23114811491.455.140.533.327.924.019.015.713.48.967.75
1.67V
38622614611291.254.740.032.927.523.718.715.513.18.777.53
1.70V
36922314511191.154.639.932.727.423.618.515.312.97.807.43
1.75V
34021614411090.254.539.832.627.223.318.415.112.88.597.29
1.80V
30619213410587.853.839.732.327.023.218.215.012.77.726.42
1.83V
27418212910285.853.739.232.226.923.118.114.812.57.616.33
1.85V
2641751249983.252.438.932.126.823.017.914.612.37.496.22

 

Discharge Data with Constant Power Units: Watts per cell (25ºC,77oF)
End voltage/cell
5min
15min
30min
45min1h2h3h4h5h6h8h10h12h20h24h
1.60V
741
42628622318411582.868.056.648.637.931.126.416.714.2
1.67V
68841928422118211382.167.456.148.237.630.926.216.413.8
1.70V
65641428322018111281.567.055.747.837.430.826.116.213.6
1.75V
60440227921818011181.266.955.547.737.130.626.016.113.5
1.80V
56336926220817511080.666.855.147.437.030.125.315.412.9
1.83V
50734725220317210980.266.154.647.336.529.524.912.212.5
1.85V
50634624919916710577.864.153.546.035.929.424.714.411.8
 
Charging Procedures
Application 
Charge Voltage (V/Cell)
Max. Charge Current
Temperature
Set Point
Allowable Range
Cycle
25ºC
2.40
2.35 ~ 2.40
0.25C
Standby
25ºC
2.25
2.23 ~ 2.27

 

Charging Procedures
Final Discharge
Voltage V/Cell
1.80
1.701.551.30
Discharge
Current (A)
0.2C ≥ (A)
0.2C < (A) < 0.5C
0.5C < (A) < 1.0C
(A) > 1.0C

 

Hot Products

Small Volume, Save Installation Space and Cost Embedded Switch Mode Power Supply Introduction ...
Front Terminal Design 6-FMX Series VRLA Battery Benefits - Front terminal design, easy access for ...
Optimal Energy Density 6-FMX Series VRLA Battery Benefits - Front terminal design, easy access for ...
Save Floor Space 6-FMX Series VRLA Battery Benefits - Front terminal design, easy access for faster ...
Centralised Venting System LR-6-GFM150 VRLA Battery Introduction The Acme T range of access VRLA ...
Reduce The Occupied Area 6-XFMJ Series VRLA Battery Benefits - Long life design for float applicatio...