Home Companies Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

High Accuracy Three Phase Power Analyzer / Portable Power Analyzer For Distribution

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Active Member

Contact Us

[China] country

Address: Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China

Contact name:Andy

Inquir Now

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

High Accuracy Three Phase Power Analyzer / Portable Power Analyzer For Distribution

Country/Region china
City & Province beijing beijing
Categories Other Electric Power Tools
InquireNow

Product Details

 

 

GF438II three phase portable power quality and energy analyzer With Inrush current & High-order harmonics

 

 

GFUVE portable power meters and analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The new and improved GF438II is a power quality analyzer for monitoring and recording power supply anomalies, allowing their causes to be quickly investigated, and also for assessing power supply problems such as voltage drops, flicker, harmonics, and other electrical issues. New features include the ability to drive current sensors straight from the PQA and enhanced recording capabilities.

 

The GFUVE GF438II power quality analyzers are designed for users who need to get to the solution of the power quality problem as quickly as possible so that they can minimize expensive downtime.

  • Measure multiple parameters simultaneously to quickly understand overall power quality health
  • View data as simple digital values or more detailed trend graphs that give you fast insight into changes over time, waveforms, and phasor diagrams
  • Organize data in tabular format so you can quickly correlate parameters like magnitude, duration, and time to the issues you are experiencing in your facility

APPLICATION

Electrical Power Systems
Power Plants
Photovoltaic
Distribution


Industrial Systems
LV Installations Safety / Quality
UPS Systems testing
Switchboards / Controlgears
Machines / Power Loads
Electrical Equipment / Appliances
Maintenance / Troubleshooting
3-phase system testing
High level industrial testing
Mid level industrial testing


Buildings Facility Management
Public areas Safety / Quality
Voltage Quality / Power Loads


Special Installations / Locations
Construction Sites
Railway Systems
Ships / Boats / Marina Places
Fire Brigade Vehicles
Military / Police Vehicles
Mobile LV Generator Units
Medical Sites / Surgery Rooms
Laboratory use
Service / Repair / Rental Offices
Electric motors testing

FEATURES

• Verify power problems in accordance with the IEC61000-4-30 Class A standard
• High accuracy and continuous gapless recording
(V: ±0.1% of nominal voltage, A: ±0.1% rdg. ±0.1% f.s., W: ±0.2% rdg. ±0.1% f.s.)
• Broadband voltage range lets you measure even high-order harmonic components of up to 80 kHz
• Maximum 6000 V peak transient voltage up to 700 kHz
• Measure up to 6000 A AC
• Two systems of power measurement and efficiency calculation for (ch 1, ch 2, ch 3) and ch 4
• Make simple measurements of inverters with 40 to 70 Hz fundamental frequency and max. 20 kHz carrier frequency
• Easily create reports with bundled PQ ONE application software
• Optional GPS BOX for synchronizing multiple devices
 

FUNCTIONS

GF438II PQA can measure all parameters at once, including power, harmonics, and anomaly waveforms.
Transient voltages
Voltage swells
Voltage dips
Interruptions
Frequency fluctuations
Inrush current
Harmonics
High-order harmonics
Unbalance
 
When an event occurs, the instrument records the instantaneous waveform for 0.2 seconds.
Triggers can be set for all event parameters in parallel, and you can check recorded data on the display while measurement is in progress.
When a voltage swell, dip, or inrush current event occurs, the GF438II PQA can simultaneously record 1/2 RMS value fluctuations for 30 seconds.
 

Specification

Measurement line typeSingle-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel for voltage, current, power measurement (AC or DC measurement)
Voltage rangesVoltage measurement: 1000.00 V rms
Transient measurement 6.0000 kV peak
Current ranges100.00 mA to 6.0000 kA AC (depends on current sensor in use)
Power ranges300.00 W to 3.0000 MW (determined automatically based on voltage and current range in use)
Basic accuracyVoltage: ±0.1% of nominal voltage
Current: ±0.1 % rdg. ±0.1 % f.s. + current sensor accuracy
Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy
Measurement items1. Transient voltage : 2 MHz sampling
2. Frequency cycle : Calculated as one cycle, 40 to 70 Hz
3. Voltage (1/2) RMS: one cycle calculation refreshed every half cycle
Current (1/2) RMS: half-cycle calculation
4. Voltage swell, Voltage dips, Voltage interruption
5. Inrush current
6. Voltage waveform comparison
7. Instantaneous flicker value: As per IEC61000-4-15
8. 200 ms frequency: Calculated as 10 or 12 cycles,40 to 70 Hz
9. 10 sec frequency: Calculated as the whole-cycle time during the specified 10 s period, 40 to 70 Hz
10. Voltage waveform peak, Current waveform peak
11. Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Reactive energy, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor, and efficiency
12. High-order harmonic component (voltage/ current): 2 kHz to 80 kHz
13. Harmonic/ Harmonic phase angle (voltage/ current), Harmonic power: 0th to 50 th orders
14. Harmonic voltage-current phase angle: 1th to 50 th orders
15. Total harmonic distortion factor (voltage/ current)
16. Inter harmonic (voltage/ current): 0.5 th to 49.5 th order
17. K Factor (multiplication factor)
18. IEC Flicker, Δ V10 Flicker
RecordRepeated ON: 1 year, Maximum recording event: 9999 × 366 days (up to 9999 events per day)
Repeated off: 35 days, maximum recording event: 9999 events
InterfacesSD/SDHC memory card, LAN (HTTP server function / FTP function), USB2.0 (for communication)
Display6.5-inch TFT color LCD (640 × 480 dots)
Power supplyAC adapter  (100 V to 240 V AC, 50/60 Hz, rated current 1.7 A), Battery Pack (Continuous use: 180 minutes, Charging time: Max. 5 hr 30 m with AC adapter)
Dimensions and mass300 mm (11.81 in)W × 211 mm (8.31 in)H × 68 mm (2.68 in)D, 1.6 kg (91.7 oz) (including Battery )
AccessoriesManual ×1, Measurement guide ×1, Voltage Cord 1000V ×1 set (Red/ Yellow/ Blue/ Gray each 1, Black 4, 3m (9.84ft) length, Alligator clip ×5), Color clip, AC Adapter 1, SD Memory Card 32GB , Application software (PQA U disk) ×1

 

Hot Products

LZCG530-10 Protection relay device using 5P20 50/1A Zero Sequence Current Transformer Zero Sequence ...
LZCG530-10 Zero Phase Current Transformer, Ring net cabinet 5P10 Ratio 100A / 1A Zero Sequence ...
LZCK2500-10 120mm 50/5a Resin Casting Split core Protection Zero Sequence Current Transformer 5P20 ...
LZCK-55 GFUVE 100A/5A IP67 Outdoor installation Split Core Clamp On Current Transformer Clamp-On ...
LMCK185-10 2000A /5A 0.5s IEC60044-1 IP67 Outdoor split core current transformer manufacturers ...
LZCK-55 Outdoors Split Core Current Transformer Description LZCK series current transformers are ...