Home Companies Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

0.5% Accuracy Primary Current Injection Test Kit CT Ratio Testing 25kg

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Active Member

Contact Us

[China] country

Address: Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China

Contact name:Andy

Inquir Now

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

0.5% Accuracy Primary Current Injection Test Kit CT Ratio Testing 25kg

Country/Region china
City & Province beijing beijing
Categories Polishers
InquireNow

Product Details

TEST-901 GFUVE with timer circuit breaker testing of 1000A primary current injection test set

 

TEST-901 primary current injection test set adopts ARM Chip to control its output process and large capacity of toroidal transformers. It is equipped with LCD display and current meter; it can show primary current value, second current value, turn ratio and the action time. Packing is used as aluminum alloy body with PC panel. TEST-901 is mainly applied to CT turn ratio testing in the power system and contact resistance test which need large current.

 

The primary current injection method is usually the preferred test method because it includes the current sensors, wiring, and the current conduction path in the circuit breaker with the test. However, this method has one disadvantage in that it will not always detect sensor wiring and polarity problems.

Primary injection test systems. A large current (between 100A and 20,000A depending on system specifications and test requirements) is injected directly on the primary side of the electrical system such as a circuit breaker. The objective of the test is to identify how the system operates under various levels of current load.

Primary Injection Primary and secondary current injection tests are normally conducted to check the operation of circuit breaker and their protective relays/devices. The protective devices installed vary from circuit to circuit depending on the protection needs and philosphy but typical relays/devices include overload, over current, reverse etc
The primary injection testing is the only way to prove correct installation and operation of the whole protection chain, as involves testing the entire circuit; current transformer primary and secondary windings, relays, trip and alarm circuits, circuit breakers and all wiring are checked.

Parameters

Electrical parameters 
Accuracy±0.5%
Power Supply(AC)220V±10%·25A, 50Hz/60Hz or
110V±10%·50A, 50Hz/60Hz
Current Output (AC)1000A·5V or 500A·10V
Capacity5KVA
The current output waveform distortion≤5%
Dual protectionoverload electronic protection and software protection
Primary current 
Range0-1100A
Resolution0.1A
Accuracy<0.5%
Secondary measurement 
Range0-6A
Resolution0.001A
Accuracy<0.5%
Current duration 
1000A range1000A 2-3minutes
500A 3-6minutes
500A range500A 2-3minutes
With timer
Range0.0001~999.99S
Resolution0.001S
Accuracy<0.5%±5 words
Mechanical parameters 
Dimensions (W×D×H) (mm)430×260×260
Weight(kg)25
Environmental conditions 
Temperature-10°C to 40°C
Relative humidity≤80%

Selection Guide

ModelACCU
RACY
Primary
current
AMMETER
(0-6A)
TIMERPOWERINJECTION CURRENT TIMEDIMENSION(W×D×H)(mm)WEIGHTREMARK
TEST-9010.5%0-1100AYESYES5KVA1000A: 2-3min;
500A:3-6min
430×260×26025KGIntegrated structure
TEST-9020.5%0-2200AYESOPTIONAL12KVA2000A:2-3min;
1000A:3-6min
360×300×295 and 320×300×30035KG+15KGFission structure
TEST-9030.5%0-3300AYESOPTIONAL15KVA3000A:2-3min;
1500A:3-6min
380×350×360 and 340×290×42048KG+42KGFission structure
TEST-9050.5%0-5500AYESOPTIONAL25KVA5000A:2-3min;
2500A:3-6min
430×430×445 and 550×450×60068KG+55KGFission structure

Photo

 

Hot Products

LZCG530-10 Protection relay device using 5P20 50/1A Zero Sequence Current Transformer Zero Sequence ...
LZCG530-10 Zero Phase Current Transformer, Ring net cabinet 5P10 Ratio 100A / 1A Zero Sequence ...
LZCK2500-10 120mm 50/5a Resin Casting Split core Protection Zero Sequence Current Transformer 5P20 ...
Outdoors waterproof 1500A medium voltage Φ55 permalloy split core current transformer LZCK series ...
LZCK-55 GFUVE 100A/5A IP67 Outdoor installation Split Core Clamp On Current Transformer Clamp-On ...
LMCK185-10 2000A /5A 0.5s IEC60044-1 IP67 Outdoor split core current transformer manufacturers ...