Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd. |
|
IP65 Proofwater Split Core Current Transformer for Measurement
Introduction
TheLZCK-55-4 current instrument transformers are fully enclosed and cast in epoxy resin. Transformer is equipped with one core and coil assembly rated for measurement and protection. The current transformers are designed for electric power systems of 50Hz/60Hz rated frequency and 36kV rated voltage. They are used for outdoor mounting. The performances of the products meet standards IEC60044-1, IEC61869-2 and ANSI/IEEE C57.13. The products are applied to metering electric energy, voltage controlling and relay protection
Features
New magnetic material is taken to be the core of the current
transformer, which has high magnetic permeability, low saturation
magnetization and good stability. Therefore, the measuring accuracy
is higher and the instrument security factor is lower. Since the
high quality silicon processed by advanced technology is taken to
be the core of the protection windings, which assured the accuracy
limit factor is higher.
The semicircular ring core and secondary windings are vacuum poured
by high quality epoxide resin in the fire retardant plastic casing,
which has the characteristic of moisture proof, stable performance
and dispensing with maintenance.Small size, light weight, small
footprint, fixed in the ring network switchgear cable.The cable can
cross the current transformer through its internal poles quickly
and uniformly.
The Cast Resin Straight-Through Current Transformer can be divided
several kinds according to the various current ratio, accuracy and
rated loads. The specific parameters are showed in the
corresponding to each model parameter tables.
PARAMETERS
Technical parameters | |
---|---|
Standards | IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13 |
Accuracy Class | 0.5S, 0.5%, 1%, 3% |
Range of primary rated current | 100-1500A |
Range of Rated load | ≤10VA |
Rated frequency | 50/60Hz |
Rated secondary current | 5A or 1A |
Rated short-time thermal current | 40kA, 1S |
Rated continuous thermal current | 150%I1n |
Secondary winding power frequency withstand voltage | 3kV, 1min |
Safety Factor Rating | (FS) <10 |
Output signal | 1A, 5A, 333mV, 1V or 5V(customized) |
Cable length | 2.5m, 5m, 10m(customized) |
Flame retardant ABS plastic shell inside, jaw waterproof apron. | |
Mechanical parameters | |
Aperture (mm) | Φ55 |
Dimensions (W×D×H) (mm) | 180×138×52 |
Weight (kg) | 2 |
Working conditions | |
Operating temperature | -35°C to +65°C, not exceeding +40°C |
Storage temperature | -40°C to +70°C |
Ingress Protection | IP65 |
Environment | outdoors or indoors |
The Height of above sea level | 0- 3000m |
Conditions | No existence of severely begrimed, erosive and radioactive gas in the air. Continuous working under the rated current is allowed. |
SELECTION GUIDE
Model | Primary rated current | Rated load | Aperture (mm) | Description (mm) | Weight (kg) | Material | Water-proof |
---|---|---|---|---|---|---|---|
LZCK-55 | 100-1500A | ≤10VA | φ55 | 180×138×52 | 2 | PC | IP67 |
LMCK185-10 | 300-3000A | ≤25VA | φ185 | 350×283×55 | 4.5 | PC | IP65 |
LZCK310-10 | 300-600A | ≤10VA | φ50 | φ50 x φ110 x 32 | 1 | Resin | silicon case (option) |
LZCK322-10 | 30-600A | ≤10VA | φ50 | φ50 x φ110 x 52 | 1.6 | Resin | silicon case (option) |
LZCK350-10 | 20-600A | ≤25VA | φ50 | φ50 x φ110 x 105 | 3.1 | Resin | silicon case (option) |
LZCG530-10 | 30-600A | ≤20VA | φ45 | φ45 x φ120 x 65 | 2.1 | Resin | silicon case (option) |
Dimension
Product Photo