Home Companies Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

33KV Medium Voltage Instrument Current Transformer Epoxy Resin Casting CE Marked

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Active Member

Contact Us

[China] country

Address: Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China

Contact name:Andy

Inquir Now

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

33KV Medium Voltage Instrument Current Transformer Epoxy Resin Casting CE Marked

Country/Region china
City & Province beijing beijing
InquireNow

Product Details

 

Epoxy Resin Cast 33KV Medium Voltage Outdoor current instrument transformer

 

 

 

Features


New magnetic material is taken to be the core of the current instrument transformer, which has high magnetic permeability, low saturation magnetization and good stability. Therefore, the measuring accuracy is higher and the instrument security factor is lower. Since the high quality silicon processed by advanced technology is taken to be the core of the protection windings, which assured the accuracy limit factor is higher.
The semicircular ring core and secondary windings are vacuum poured by high quality epoxide resin in the fire retardant plastic casing, which has the characteristic of moisture proof, stable performance and dispensing with maintenance.Small size, light weight, small footprint, fixed in the ring network switchgear cable.The cable can cross the current transformer through its internal poles quickly and uniformly.
The Cast Resin Straight-Through Current Transformer can be divided several kinds according to the various current ratio, accuracy and rated loads. The specific parameters are showed in the corresponding to each model parameter tables.

High precision 0.2s

Designed for 30years lifes

Good Stability in 33kv power line

Big burden.

Multi ratio CT

 

 

 

Theory

 

 

Instrument transformers are high accuracy class electrical devices used to isolate or transform voltage or current levels. The most common usage of instrument transformers is to operate instruments or metering from high voltage or high current circuits, safely isolating secondary control circuitry from the high voltages or currents. The primary winding of the transformer is connected to the high voltage or high current circuit, and the meter or relay is connected to the secondary circuit.
Instrument transformers may also be used as an isolation transformer so that secondary quantities may be used in phase shifting without affecting other primary connected devices.
Current transformers (CT) are a series connected type of instrument transformer. They are designed to present negligible load to the supply being measured and have an accurate current ratio and phase relationship to enable accurate secondary connected metering.
Current transformers are often constructed by passing a single primary turn (either an insulated cable or an uninsulated bus bar) through a well-insulated toroidal core wrapped with many turns of wire. This affords easy implementation on high voltage bushings of grid transformers and other devices by installing the secondary turn core inside high-voltage bushing insulators and using the pass-through conductor as a single turn primary.

 

 

 

Applications

 

 

The LZZW3-35Q outdoor current instrument transformers are fully enclosed and cast in epoxy resin. Instrument transformer is equipped with one core and coil assembly rated for measurement and protection, and then output multi ratio. The current transformers are designed for electric power systems of 50Hz/60Hz rated frequency and 35kV rated voltage. They are used for outdoor mounting. The performances of the products meet standards IEC60044-1, IEC61869-2 and ANSI/IEEE C57.13. The products are applied to metering electric energy, voltage controlling and relay protection.

1. Measurement current & voltage  for energy meter and power meter

2. Supply protection current signal for microcomputer protection relay set
 

 

 

 

PARAMETERS

 

TECHNICAL DATA 1: TWO WINDINGS

 

Rated primary current(A)Accuracy class combinationRated secondary output(VA)Surface creepage distance
(mm)
Weight(KG)
1S/2S0.2(S)0.5S0.55P105P155P20
10-6300.2(S)/0.5(S)
0.2(S)/5p
0.5(S)/5p
 
10201006040130090
750-20001207550

 

 

TECHNICAL DATA 2: THREE WINDINGS

 

Rated primary current(A)Accuracy class combinationRated secondary output(VA)Surface creepage distance
(mm)
Weight(KG)
1s/2s/3s0.2(s)0.5S0.55P105P155P20
10-5000.2(S)/0.2(S)/5P
0.2(S)/0.5(S)/5p
0.5(S)/0.5(S)5p
 
1020503025130090
600-1000805030
1200-20001006040
100-6300.2(S)/5p/5p
0.5(S)/5p/5p
1020302015
750-1000503020
1200-1600603025
2000604025

 

 

TECHNICAL DATA 3: FOUR WINDINGS SINGLS TRANSFORMAITON RADIO

 

Rated primary current(A)Accuracy class combinationRated secondary output(VA)Surface creepage distance
(mm)
Weight(KG)
1s/2s/3s/4s0.2(s)0.5s0.55P105P155P20
10-8000.2(S)/0.2(S)/5P/5P
0.2(S)/0.5(S)/5p/5P
0.5(S)/0.5(S)5p/5P
 
1020251510130090
1000305010
1200-2000402515

 

 

TECHNICAL DATA 4: THREE WINDINGS SINGLS TRANSFORMAITON RADIO

 

Rated primary current (A)Accuracy
class combination
Rated secondary output(VA)Surface creepage distance (mm)Wt
(KG)
1s/2s/3s/4s0.2(S)0.5s0.55P105P155P20
10-15-2010251090
15-20-30
20-30-40
30-40-50
40-50-75
50-75-100
75-100-150
100-150-200
150-200-300
200-300-400
300-400-500
400-500-600
500-600-800
600-800-1200
800-1200-1500
1200-1500-2000

 

TECHNICAL DATA 5: IDYN

 

TECHNICAL DATA 5: IDYN

 

Rated primary current (A)Ith/ls (KA r.m.s.)Idyn (KA peak)
Double transformaion ratioSingle transformaion ratio
10-15-201025
15-20-301537.5
20-30-4020,25410
30-40-50306.315.7
40-50-75409.423.6
50-75-1005012.631.5
75-100-1507515.739
100-150-2001002255
150-200-30015031.578.7
200-300-400200,25047118
300-400-50030063157.5
400-500-60040063157.5
500-600-80050080200
600-800-1200600-120080200
800-1200-15001500-2000140200
1200-1500-2000

 

 

 

 

 

Hot Products

LZZT620-10 resin cast Three phase bushing type Zero Sequence Current Transformer for protection ...
LZZT943-10 resin cast Three phase Zero Sequence Current Transformer for Ring cabinet and inflatable ...
150mm diameter 2000A/1A 5P20 Cast Resin Zero Sequence Current Transformer with IEC 61869-2 LZCK2501 ...
LZCG530-10 Protection relay device using 5P20 50/1A Zero Sequence Current Transformer Zero Sequence ...
LZCG530-10 Zero Phase Current Transformer, Ring net cabinet 5P10 Ratio 100A / 1A Zero Sequence ...
LZCK2500-10 120mm 50/5a Resin Casting Split core Protection Zero Sequence Current Transformer 5P20 ...