Hunan Zhengzhong Pharmaceutical Machinery Co., Ltd |
|
Z-Zone Servo Vial Leakage Test Machine
Application
The apparatus is designed specifically for the examination of vials and oral liquid commodities with regards to any probable liquid seepage. It is capable of detecting pinhole and fissures on said containers.
Parameters
Application | 1-20ml |
Capacity | 300-400 bottles/min |
Power | 2.4kW,380V50Hz |
Weight | about 1000kg |
Dimension | 3694mm×1180mm×1364mm(L×W×H) |
Output power range | 10kV~35 kV |
Output frequency range | 500Hz~50kHz |
Warranty | 2Years |
Working principle
V is a power supply designed for high-frequency and high-voltage detection. It operates by connecting the launch and receiving pole to both ends, with C1 and C2 representing the capacitance value between the electrode and the capacitor. As the bottle wall partitions prohibit direct contact between the electrode and medicinal solution, capacitance is generated instead. The resistance value of the medicinal solution is represented as R. In the event that the ampoule bottle is not leaked, an inductive micro-circular I1 is generated. However, when the bottle leaks, the capacitance between the insulation bottle and the electrode is eliminated, resulting in a larger current I2 being generated within the circuit. With a simple comparison of the micro current levels, it becomes possible to determine whether the bottle has been leaked.