Single core and 3 cores CU/XLPE/CTS/STA/LSOH power cable rated voltage 6/10(12)kV

Country/Region china
City & Province jiaxing zhejiang
Categories Power Cables
InquireNow

Product Details

Single core and 3 cores CU/XLPE/CTS/STA/LSOH power cable rated voltage 6/10(12)kV
Detailed Product Description
 
Applications
Laying in room ,tunnel ,cable trench ,and pipes.


Certificates
CE, SGS, KEMA and more others at reques.


Note:
Insulation identification as per standards or customer requirement


Standards
International: IEC 60502, IEC 60228, IEC 60332, IEC 60754
China: GB∕T 12706.2-2008, GB∕T 19666-2005
Other standards such as BS,VDE and ICEA upon request


Technical data
Rated voltage: 6/10 kV
Maximum Conductor Temperature: under normal (90 ℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions.
Min. Ambient Temp.: The cable shall be pre heated if the ambient temperature is below 0℃
Min. Bending Radius: single core cable 20(d+D)±5%
Multi-core cable 15(d+D)±5%
 
What is LSOH Power Cable
Typical structure of LSOH flame-retardant cable: non-metallic cable cladding material is LSOH flame-retardant material with different properties. This structure enables the cable to pass class A tests in IEC 60332-3-22 and related tests in IEC 60754 and IEC 61034.


Benefits of FR Cable
When a fire occurs, the combustion of combustibles in the ordinary power system will produce a large amount of halogen-containing smoke. The LSOH power cable and the LSOH building materials used together can effectively reduce the total amount of smoke released by combustible combustion and the content of halogen, so as to reduce the casualty rate in the fire.
The cable has good radial compressive performance.
 
Constructions
Conductor : Compact stranded copper conductor, Cl.2 as per IEC 60228
Conductor Screen: Semi-conductor
Insulation : XLPE(cross-linked polyethylene) rated at 90 ℃
Insulation Screen: Semi-conductor
Screen : Copper tape
Interlining: LSOH Flame Retardant Polyolefin, black
Armouring: STA(Steel-Tape Armouring)
Sheath : LSOH Flame Retardant Polyolefin, black
 
Technical Specifications

Nom. Cross-section of conductorStrands No./Dia. Of ConductorInsulation
Thickness
Thickness of Copper StripThickness of steel tapeSheath ThicknessApprox. O.D.Approx.Max. D.C Resistance of Conductor (20 ℃)Testing Voltage A.CCurrent Rating
WeightIn air (A)In soil(A)
1×257/2.17+0.013.40.120.21.823.98720.72724165160
1×357/2.56+0.013.40.120.21.824.99990.52424205190
1×5019/1.86+0.013.40.120.21.826.211610.38724245225
1×7014/2.56+0.013.40.120.21.827.914130.26824305275
1×9519/2.56+0.023.40.120.21.929.717240.19324370330
1×12024/2.56+0.023.40.120.21.931.220000.15324430375
1×15030/2.56+0.013.40.120.22.032.823130.12424490425
1×18537/2.56+0.023.40.120.22.034.627290.099124560480
1×24048/2.58+0.023.40.120.52.138.837350.075424665555
1×30060/2.58+0.023.40.120.52.241.244040.060124765630
1×40060/2.93+0.023.40.120.52.344.554030.04724890725
1×50060/3.33+0.023.40.120.52.447.966170.0366241030825
1×63060/3.76+0.023.40.120.52.551.780850.0283241200950
3×257/2.17+0.013.40.100.52.446.131430.72724120125
3×357/2.56+0.013.40.100.52.448.335760.52424140155
3×5019/1.86+0.013.40.100.52.652.342290.38724165180
3×7014/2.56+0.013.40.100.52.756.351350.26824210220
3×9519/2.56+0.023.40.100.52.860.061570.19324255265
3×12024/2.56+0.023.40.100.52.963.671420.15324290300
3×15030/2.56+0.013.40.100.53.066.881670.12424330340
3×18537/2.56+0.023.40.100.53.171.196140.099124375380
3×24048/2.58+0.023.40.100.53.376.5117020.075424435435
3×30060/2.58+0.023.40.100.53.581.8138790.060124493485
3×40060/2.93+0.023.40.100.83.789.8178860.04724565520
 

 
Ordering Advice
Rated Voltage
Application Standard: IEC/BS/UL/GB
Number of Cores
Conductor Size & Construction
Type of Insulation
Armored or unarmored. If armor, the armor type & material
The Requirement of Sheath
Length of Cable & Packing Requirement
Other Requirement
 
Packing and shipping
steel wooden drum, other as required and shipping in general is by sea.
 

Cable Drum Data

CABLE DRUMSD1=Flange Diameter(mm)W=Useful Width (mm)D2=Barrel Diameter(mm)
1000700500
1100700550
1200700600
1400750710
1600900900
180011201000
240011501300

 
 
Product photo

Hot Products

IEC60502.2 approval MV power cable with copper conductor XLPE insulation/STA/ LSOH sheath Detailed ...
Single core and 3 cores CU/XLPE/CTS/STA/LSOH power cable rated voltage 6/10(12)kV Detailed Product ...
Underground MV power cable with cu/XLPE/CTS/LSOH/STA/LSOH rated voltage 8.7/15kV Detailed Product ...
12/20kV copper conductor XLPE insulation LSOH flame retardant armored power cable Detailed Product ...
Underground MV power cable with cu/XLPE/CTS/LSOH/STA/LSOH rated voltage 12/20kV Detailed Product ...
Cu/XLPE/CTS/ /LSOH 24kV steel tape armored power cable 3X120 mm2 Detailed Product Description ...