15kv xlpe underground power cables single core or three phase MV copper cables
 

Detailed Product Description

 
Certificates
CE, SGS, KEMA and more others at request
 
 
Note:
Insulation identification as per standards or customer requirement
Applications
Laying in room ,tunnel ,cable trench ,and pipes.
 

What is LSOH Power Cable
Typical structure of LSOH flame-retardant cable: non-metallic cable cladding material is LSOH flame-retardant material with different properties. This structure enables the cable to pass class A tests in IEC 60332-3-22 and related tests in IEC 60754 and IEC 61034.
 
Benefits of FR Cable
When a fire occurs, the combustion of combustibles in the ordinary power system will produce a large amount of halogen-containing smoke. The LSOH power cable and the LSOH building materials used together can effectively reduce the total amount of smoke released by combustible combustion and the content of halogen, so as to reduce the casualty rate in the fire.
 
Constructions
Conductor : Compact stranded copper conductor, Cl.2 as per IEC 60228
Conductor Screen: Semi-conductor
Insulation : XLPE(cross-linked polyethylene) rated at 90 ℃
Insulation Screen: Semi-conductor
Screen : Copper tape
Sheath : LSOH Flame Retardant Polyolefin, black
 
Standards

  • IEC 60502-2 Power cables with extruded insulation and their accessories for rated voltages of 1 kV and 3 kV.
  • IEC 60754 Test on gases evolved during combustion of materials from cables.
  • IEC 61034 Measurement of smoke density of cables burning under defined conditions.
  • BS 7870-3 LV and MV polymeric insulated cables for use by distribution and generation utilities.
  • DIN VDE0276-603 Power cables - Part 603: Distribution cables of rated voltage 0,6/1 kV.
  • ANSI/NEMA WC 70-2009/ICEAS-95-658 Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy.
  • AS/NZS 4026:2008 Electric cables - For underground residential distribution systems Standards Australia.
  • AS/NZS 4961:2003 Electric cables - Polymeric insulated - For distribution and service applications.
  • AS/NZS 5000.1:2005 Electric cables - Polymeric insulated - For working voltages up to and including 0.6/1 (1.2) kV.
  • Other Equivalent standards for PVC insulated power cable.

 
Technical data
Rated voltage: 8.7/10 kV
Maximum Conductor Temperature: under normal (90 ℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions.
Min. Ambient Temp.: The cable shall be pre heated if the ambient temperature is below 0℃
Min. Bending Radius: single core cable 20(d+D)±5%
Multi-core cable 15(d+D)±5%
 
Technical Specifications
 

Nom. Cross-section of conductorStrands No./Dia. Of ConductorInsulation
Thickness
Thickness of Copper StripSheath ThicknessApprox. O.D.Approx.Max. D.C Resistance of Conductor (20 ℃)Testing Voltage A.CCurrent Rating
WeightIn air (A)In soil(A)
1×257/2.17+0.014.50.121.822.97040.72735165160
1×357/2.56+0.014.50.121.823.98220.52435205190
1×5019/1.86+0.014.50.121.825.29730.38735245225
1×7014/2.56+0.014.50.121.826.912090.26835305275
1×9519/2.56+0.024.50.121.828.514930.19335370330
1×12024/2.56+0.024.50.121.930.217670.15335430375
1×15030/2.56+0.014.50.121.931.620540.12435490425
1×18537/2.56+0.024.50.122.033.624680.099135560480
1×24048/2.58+0.024.50.122.136.030670.075435665555
1×30060/2.58+0.024.50.122.138.236740.060135765630
1×40060/2.93+0.024.50.122.241.345900.04735890725
1×50060/3.33+0.024.50.122.344.758930.0366351030825
1×63060/3.76+0.024.50.122.448.372860.0283351200950
3×257/2.17+0.014.50.102.445.624910.72735120125
3×357/2.56+0.014.50.102.548.129050.52435140155
3×5019/1.86+0.014.50.102.651.634600.38735165180
3×7014/2.56+0.014.50.102.755.542740.26835210220
3×9519/2.56+0.024.50.102.859.152320.19335255265
3×12024/2.56+0.024.50.102.962.661260.15335290300
3×15030/2.56+0.014.50.103.065.870950.12435330340
3×18537/2.56+0.024.50.103.169.984340.099135375380
3×24048/2.58+0.024.50.103.375.0103930.075435435435
3×30060/2.58+0.024.50.103.580.1124370.060135493485
3×40060/2.93+0.024.50.103.786.8154240.04735565520
 

 

Packing: steel wooden drum, other as required

Cable Drum Data

CABLE DRUMSD1=Flange Diameter(mm)W=Useful Width (mm)D2=Barrel Diameter(mm)
1000700500
1100700550
1200700600
1400750710
1600900900
180011201000
240011501300
 

 

 

Hot Products

IEC 60502 Approval N2XH Low Smoke Zero Halogen SWA armored Power Cable Four Cores XLPE Insulated ...
15kv xlpe underground power cables single core or three phase MV copper cables Detailed Product ...
Low Smoke Zero Halogen Cable Environment Friendly Power Cable as per BS6724 Detailed Product ...
19/33kV XLPE Insulated, LSOH Sheathed, un-armoured Flame Retardant MV Power Cable Detailed Product ...
Eco Friendly Low Smoke Zero Halogen Power Cable 600 / 1000v Rated Voltage Detailed Product ...
Low Smoke Zero Halogen flame retardant catalogue A,B,C power cable with rated voltage 0.6/1KV ...