Home Companies Zhejiang CHINT Cable Co., Ltd

PP Filler Low Smoke Zero Halogen Power Cable 12/20kV Compact Stranded Copper Conductor

Zhejiang CHINT Cable Co., Ltd

Contact Us

[China] country

Trade Verify

Address: 1#Jiangnan Road,Nanhu district ,Jiaxing city, Zhejiang province China

Contact name:May

Inquir Now

Zhejiang CHINT Cable Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

PP Filler Low Smoke Zero Halogen Power Cable 12/20kV Compact Stranded Copper Conductor

Country/Region china
City & Province jiaxing zhejiang
Categories Power Cables
InquireNow

Product Details

Underground MV power cable with cu/XLPE/CTS/LSOH rated voltage 12/20kV

 

Detailed Product Description

 

Certificates

CE, SGS, KEMA and more others at request

 

Note:

Insulation identification as per standards or customer requirement

 

Applications

Laying in room ,tunnel ,cable trench ,and pipes.

 

Constructions

Conductor : Compact stranded copper conductor, Cl.2 as per IEC 60228

Conductor Screen: Semi-conductor

Insulation : XLPE(cross-linked polyethylene) rated at 90 ℃

Insulation Screen: Semi-conductor

Screen : Copper tape

Sheath : LSOH Flame Retardant Polyolefin, black

 

Standards

  • IEC 60502-2 Power cables with extruded insulation and their accessories for rated voltages of 1 kV and 3 kV.
  • IEC 60754 Test on gases evolved during combustion of materials from cables.
  • IEC 61034 Measurement of smoke density of cables burning under defined conditions.
  • BS 7870-3 LV and MV polymeric insulated cables for use by distribution and generation utilities.
  • DIN VDE0276-603 Power cables - Part 603: Distribution cables of rated voltage 0,6/1 kV.
  • ANSI/NEMA WC 70-2009/ICEAS-95-658 Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy.
  • AS/NZS 4026:2008 Electric cables - For underground residential distribution systems Standards Australia.
  • AS/NZS 4961:2003 Electric cables - Polymeric insulated - For distribution and service applications.
  • AS/NZS 5000.1:2005 Electric cables - Polymeric insulated - For working voltages up to and including 0.6/1 (1.2) kV.

Other Equivalent standards for PVC insulated power cable

 

Technical data

Rated voltage: 12/20 kV

Maximum Conductor Temperature: under normal (90 ℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions.

Min. Ambient Temp.: The cable shall be pre heated if the ambient temperature is below 0℃

Min. Bending Radius: single core cable 20(d+D)±5%

Multi-core cable 15(d+D)±5%

 

Technical Specifications

 
Nom. Cross-section of conductorStrands No./Dia. Of ConductorInsulation
Thickness
Thickness of Copper StripSheath ThicknessApprox. O.D.Approx.Max. D.C Resistance of Conductor (20 ℃)Testing Voltage A.CCurrent Rating
WeightIn air (A)In soil(A)
1×357/2.56+0.015.50.121.825.99080.52448205190
1×5019/1.86+0.015.50.121.827.210630.38748245225
1×7014/2.56+0.015.50.121.828.913050.26848305275
1×9519/2.56+0.025.50.121.930.716060.19348370330
1×12024/2.56+0.025.50.121.932.218730.15348430375
1×15030/2.56+0.015.50.122.033.821780.12448490425
1×18537/2.56+0.025.50.122.035.625830.099148560480
1×24048/2.58+0.025.50.122.138.031900.075448665555
1×30060/2.58+0.025.50.122.240.438210.060148765630
1×40060/2.93+0.025.50.122.343.547470.04748890725
1×50060/3.33+0.025.50.122.446.959630.0366481030825
1×63060/3.76+0.025.50.122.550.573620.0283481200950
3×357/2.56+0.015.50.102.652.732740.52448140155
3×5019/1.86+0.015.50.102.756.138500.38748165180
3×7014/2.56+0.015.50.102.860.046890.26848210220
3×9519/2.56+0.025.50.103.063.856960.19348255265
3×12024/2.56+0.025.50.103.167.366150.15348290300
3×15030/2.56+0.015.50.103.270.576050.12448330340
3×18537/2.56+0.025.50.103.374.689720.099148375380
3×24048/2.58+0.025.50.103.579.7109670.075448435435
3×30060/2.58+0.025.50.103.684.6130100.060148493485
3×40060/2.93+0.025.50.103.891.3160410.04748565520
 

PACKING AND SHIPPING

All cable for exporting is well packed and protected by wooden drum or Wood and Steel Drum.

The packing material is depended on the weight and size of cable.

The good information, manufacture information, and the client's information is firmly printed on each size of drum.

 

After the well packed cable drums sent to Sea Port, they are loaded into 20 FT container or 40 FT container. All cable drum are firmly fixed by safety belt to make sure, no movement during the sea freight.

The size of the container is chosen according to weight of total loaded goods or as per the client's requirement.

 


 

 

Hot Products

Underground MV power cable with cu/XLPE/CTS/LSOH rated voltage 12/20kV Detailed Product Description ...
12/20kV copper conductor XLPE insulation low smoke zero halogen flame retardant power cable Detailed ...
8.7/10 or 8.7/15kV copper conductor XLPE insulation LSZH flame retardant power cable Detailed ...
3 Phase Flame Retardant LSZH Cables copper Conductor XLPE Insulated Zero Halogen MV Cable Detailed ...
18/30kV copper conductor XLPE insulation low smoke zero halogen flame retardant power cable Detailed ...
Underground MV power cable with cu/XLPE/CTS/LSOH/SWA/LSOH rated voltage 8.7/15kV Detailed Product ...