Horizontal Concealed FCU specification table | Vertical coil three pipes system | ||||||||||||
Model FP WA*-3* | 200 | 300 | 400 | 500 | 600 | 700 | 800 | 1000 | 1200 | 1400 | |||
Air volume | H | m3/h | 340 | 510 | 680 | 850 | 1020 | 1200 | 1360 | 1700 | 2040 | 2380 | |
M | 280 | 380 | 515 | 660 | 705 | 910 | 1040 | 1280 | 1560 | 1800 | |||
L | 1B0 | 260 | 340 | 430 | 530 | 610 | 710 | 860 | 1060 | 1190 | |||
Cooling capacity | H | W | 2020 | 3010 | 3700 | 4560 | 5600 | 6400 | 7600 | 9000 | 10800 | 12600 | |
M | 1683 | 2742 | 3000 | 3716 | 4424 | 5630 | 6435 | 7470 | 9296 | 10623 | |||
L | 1561 | 2293 | 2479 | 2921 | 3793 | 4905 | 5606 | 7200 | 8543 | 8820 | |||
Heating capacity | H | W | 3500 | 5300 | 6700 | 8200 | 10100 | 10940 | 13500 | 15000 | 18900 | 20000 | |
M | 2526 | 3533 | 5153 | 5954 | 7099 | 8057 | 9906 | 11560 | 15163 | 18600 | |||
L | 1682 | 2321 | 3449 | 4258 | 4833 | S558 | 6774 | 7500 | 10085 | 14240 | |||
Motor | Input power(H) | Normal ESP (12Pa) | W | 37 | 52 | 62 | 76 | 96 | 113 | 134 | 152 | 189 | 228 |
High ESP (30Pa) | 44 | 69 | 72 | 87 | 108 | 134 | 156 | 174 | 212 | 253 | |||
Super High ESP (50Pa) |
49 | 66 | 84 | 100 | 118 | 158 | 174 | 210 | 250 | 300 | |||
Heat exchanger (3-pipe) | Cooling/ Heating |
Water flow | m3/h | 0.367 | 0.517 | 0.638 | 0 796 | 0.978 | 1.128 | 1.371 | 1.516 | 1 822 | 2.152 |
Water drop pressure | kPa | 17 | 22 | 18 | 20 | 30 | 20 | 30 | 30 | 30 | 40 | ||
Noise | H | Normal ESP (12Pa) | dB(A) | ≤37 | ≤39 | ≤41 | ≤43 | ≤45 | ≤47 | ≤46 | ≤48 | ≤50 | ≤52 |
High ESP (30Pa) | ≤40 | ≤42 | ≤44 | ≤46 | ≤47 | ≤49 | ≤48 | ≤50 | ≤52 | ≤54 | |||
Super High ESP (50Pa) |
≤42 | ≤44 | ≤46 | ≤47 | ≤49 | ≤51 | ≤50 | ≤52 | ≤54 | ≤56 | |||
Dimension | Length | mm | 655 | 785 | 885 | 945 | 1065 | 1185 | 1405 | 1525 | 1725 | 1925 | |
Width | 496 | 466 | 466 | 466 | 466 | 466 | 466 | 466 | 466 | 466 | |||
Height | 243 | 243 | 243 | 243 | 243 | 243 | 243 | 243 | 243 | 243 | |||
Unit weight | No return air box | KG | 12 | 14 | 16 | 17 | 18 | 19 | 26 | 29 | 32 | 35 |
*Cold water cooling condition: return air :DB 27℃/WB 19.5℃; fresh air DB35℃/WB28℃;cold water inlet/outlet 7℃/12℃.
*Heat water cooling condition: return air :DB 15℃/fresh air DB 7℃;inlet/outlet water: 60℃/50℃.
*Heating retur air condition: DB 15℃,fresh air:DB 7 ℃/vapor inlet:115℃,pressure:0.2Mpa.
Programmable thermostats
Setting your smart or programmable thermostat at the right temperature can reduce your cooling costs by about 10 percent. The right temperature varies on your comfort level, but start by setting it at 78° F and experiment until you find the sweet spot. You’ll save about 3 percent on your utility bill for every degree you raise the set temperature for your central air, according to the Department of Energy. And keep in mind that using a box or ceiling fan, which costs little to run, can make you feel 3° F to 4° F cooler.