50ft Central Air Conditioning Unit Diagram Modular Air Handing Unit

Country/Region china
City & Province guangdong
Categories Toilet Tissue
InquireNow

Product Details

Air conditioning unit central air conditioner diagram Modular air handing unit

VENTECH(Vcare) Air Conditioning Unit Central Air Conditioner Modular air handing unit

TechAirflow
(m3/h)
Cooling coilVapor coil
Return air condition capacity(kW)Fresh air condition capacity kW)Return ar heating(kW)
Model2-row4-row6-row8-row2-row4-row6-raw8-raw1-row2-raw
VAH00110003.86.27.98.87.712.616.418.411.421.2
VAH00220007.312.015.317.115.625.633.337.422.942.8
VAH003300011.619.024.227.023.238.149.647.734.464.3
VAH004400014.123.129.532.931.351 466.975.145.184.2
VAH005500017.729.037.041.339.364.584.094.356.4104.4
VAH006600021.735,45.350.643.371.198.6104.087.6126.5
VAH007700026.343.155.061.453.688.0114.6128.778.8147.5
VAH008800031.150.964.972.463.2103.7135.0151 690.0168.4
VAH009900034.556.572.080.369.9114.7149.3167.7101.2189.4
VAH0101000037.661.678.587.680.1131.4171.1192.1112.4210.4
VAH0121200045.474.494.9105.993.2152.9189.1223.6134.8252.3
VAH0141400053.187.0110.9123.8110.9182.0237.0266.2157.2294.2
VAH0161600061.8101.2129.0144.0129.7212S277.1311.2179.6336.2
VAH0181800070.7115.8147.6164.7148.1243.0316.4355.3202.0378.1
VAH0202000080.4131.7167.9187.4164.3269.6351.0394.2225.6421.2
VAH0222200084.1137.8176.7196.1170.4279.6364.0408.8252.3467.5
VAH0242400092.3151.2192.8215.2194.5319.2415.6466.7266.3500.9
VAH02626000100.1164.0200.1233.3210.2344.9449.0504.2293.3547.6
VAH02828000107.8178.6225.2251.3220.3361.5470.7S28.6310.6564.4
VAH03030000117.0191.6244.3272.6239.7303.3512.1575.1332.7822.8
VAH03536000136.3223.3284.7317.7268.2440.1573.0643.5388.1726S
VAH04040000156.1256.7326.0363.8307.5504.6657.0737.3443.5830.2
VAH04545000169.2277.2363.4394.4364.4581.6757.2850.3498.9933.9
VAH05050000181.8297.8379.7423.7393.3645.4840.3943.7564.31037.6
VAH05555000203.4333.2424.8474.1436.7716.6933.01047.8609.71141.3
VAH06060000226.8371.5473.7528.6481.6790.31029.01156.6665.11245.0
VAH07070000266,7436.9667.0621.6548.2899.61171.31315.4775.91452.4
VAH08080000307.2503.2641.6716.0636.61044.71380.21527.5886.71659.9
VAH09090000345.7566.3722.0805.8714.51172.51526.61714.4997.51867.3
VAH100100000384 1629.2802.2895.3786.41290.51680.21886.91108.32074.7
VAH110110000398.4652.6832.1928.6----1219.12282.1
VAH12012000041.3678.8865.2985.6----1329.92489.5
VAH130130000452.9741.9945.91055.6----1440.72696 9
VAH140140000491.8806.61027.11146.2----1551.52904.4
VAH150150000523.7857.81083.71130.6----1662.33111.8
VAH160160000557.2912.71163.71298.7----1745.03279.3
VAH170170000586.3960.41224.51366.5----1854.03484.3
VAH180180000616.01009.01296.51435.7----1963.13689.2
VAH190190000647.11060.01351.51508.3----2072.13894.2
VAH200200000678.51111.41417.01581.4----2143.64061.5
VAH220220000736.41206.21537.91716.3----2399.34609.0
VAH2502S0000817.61339.21707.51905.6----2879.55029.9
 

 

*Cold water cooling condition: return air :DB 27℃/WB 19.5℃; fresh air DB35℃/WB28℃;cold water inlet/outlet 7℃/12℃.

*Heat water cooling condition: return air :DB 15℃/fresh air DB 7℃;inlet/outlet water: 60℃/50℃.

*Heating retur air condition: DB 15℃,fresh air:DB 7 ℃/vapor inlet:115℃,pressure:0.2Mpa.

 

 

Upgrading an existing system
If you’re upgrading your central air, don’t assume you should buy the same-sized system. Any changes you’ve made to improve your home’s energy efficiency, such as upgrading your windows or adding insulation, can reduce your cooling needs. On the other hand, if you’ve added rooms, you might need more cooling.

Have your contractor do a load calculation based on a recognized method, such as one in Manual J from the ACCA. The contractor’s evaluation should include whether your ducts need to be resized, sealed, and insulated, or replaced. Remember that an indoor evaporator coil and outdoor condenser must be a matched set from the same brand, or the performance, efficiency, and capacity might not meet expectations.

New systems are 20 to 40 percent more efficient than minimum-efficiency models made even 10 years ago. Costs will vary and can depend on whether you need ductwork installed, and the particular size and configuration of your home.

Air conditioning requirements across the world are increasing at a significant rate. An increase in temperature, heatwaves, and unpredictable weather is one driver for the high demand. An increase in energy efficiency and affordability is the primary demand driver. Individual requirements vary extensively, and manufacturers are innovating rapidly.

To cater to the varied requirements of home-owners, the manufacturers have made available a wide variety of air conditioners.

 

Want to learn more about Vcare Wholehouse air onditioner,please contact us by email directly.                                                     Email:karen@chinaventech.com Tel:0086 13620119598

 

 

 

 

Hot Products

Air conditioning unit central air conditioner capacitor Modular air handing unit VENTECH(Vcare) Air ...
Air conditioning unit central air conditioner components Modular air handing unit VENTECH(Vcare) Air ...
Air conditioning unit central air conditioner diagram Modular air handing unit VENTECH(Vcare) Air ...
VENTECH(Vcare) Air Conditioning Unit Central Air Conditioner Modular air handing unit Tech Airflow ...
VENTECH(Vcare) Air Conditioning Unit Central Air Conditioner Modular air handing unit Tech Airflow ...
VENTECH(Vcare) Air Conditioning Unit Central Air Conditioner Modular air handing unit Tech Airflow ...