Home Companies Ningbo Tian'an Jinghua Power Technology Co., Ltd.

35KV ONAF On Load Tap Changer S9 Single Phase Power Transformer

Ningbo Tian'an Jinghua Power Technology Co., Ltd.
Active Member

Contact Us

[China] country

Address: 21/F, Building 1, No. 816,Jinghua Road, Hi-tech Zone,Ningbo, Zhejiang, P.R. China

Contact name:Tony ma

Inquir Now

Ningbo Tian'an Jinghua Power Technology Co., Ltd.

35KV ONAF On Load Tap Changer S9 Single Phase Power Transformer

Country/Region china
City & Province ningbo zhejiang
InquireNow

Product Details

35KV three phase distribution transformer with low power loss

 

1. General of 35KV three phase distribution transformer with low power loss

1.1 Application

10~35kV class transformers are widely used in power transmission and distribution stations, industry plants, Generation Step-up Unit (GSU). They have the characteristic of high efficiency, low loss and maintenance free.

1.2 Type and Rating

Capacity range: 50-50000KVA

Secondary voltage: 415V, 400V etc.

Frequency: 50Hz, 60Hz

Type: Single phase, three phase

No-load tap changer and on-load tap changer

ONAN and ONAF

Set-up and set-down type

1.3 Standard

IEC60076-1, IEC60076-2, IEC60076-5, IEC60317, ANSI, IEEE, AS, etc.


2. Condition of service of 35KV three phase distribution transformer with low power loss

2.1.1 Altitude: Up to 1000m above sea level

2.1.2 Ambient temperature:

Max. +40℃

Average (daily, Max.) +30℃

Average (yearly, Max.) +20℃

Min. -45℃

2.1.3 Application: Outdoor

2.2 Special conditions: It may be consulted between manufacturer and customer.

 

3. Structure feature of 35KV three phase distribution transformer with low power loss

3.1Insulation oil

The tanks are filled with high quality grade mineral oil as per IEC296 and it is PCB and PCT free. The oil is used to help cooling the transformer. It is also used provide part of the electrical insulation between internal live parts.

 

4. Technical data of 35KV three phase distribution transformer with low power loss

 

Capacity

(kVA)

Voltage and tap rangeConnection

No-load Loss

(kW)

Load loss (kW)No-load current (%)Impedance(%)

Dimensions

LxWxH(mm)

HV

(kV)

MV

(kV)

LV(kV)
5035±50.4

Dyn11

Yyn0

0.211.27/1.212.006.51100x845x1715
1000.292.12/2.021.801190x915x1780
1250.342.50/2.381.701220x1040x1780
1600.362.97/2.831.601240x1070x1810
2000.433.50/3.331.501380x780x1875
2500.514.16/3.961.401540x880x1820
3150.615.01/4.771.401440x800x1975
4000.736.05/5.761.301660x825x1995
5000.867.28/6.931.201710x865x2030
6301.048.281.101630x1235x2070
8001.239.901.001655x1415x2120
10001.4412.151.001860x1435x2220
12501.7614.670.901890x1640x2260
16002.1217.550.802050x1720x2390
630

3.15

6.3

10.5

Yd111.048.281.101630x1235x2070
8001.239.901.001655x1415x2120
10001.4412.151.001860x1435x2220
12501.7614.670.901890x1640x2260
16002.1217.550.802050x1720x2390
20002.7219.350.702400x1900x2410
25003.2020.700.602500x1930x2700
315035~38.5±5

3.15

6.3

10.5

3.8024.300.567.02600x2100x2800
40004.5228.800.562830x2350x2855
50005.4033.030.482930x2480x2930
63006.5636.900.487.53150x2330x3220
8000±2x2.5

3.15

3.3

6.3

6.6

10.5

11

Ynd119.0040.500.423295x3110x3345
1000010.8847.700.423450x3210x3440
1250012.6056.700.408.03620x3255x3500
1600015.2069.300.403980x3420x3650
2000018.0083.700.404030x3470x3690
2500021.2899.000.325050x4640x3930
3150025.28118.80.325120x4800x4030

 

Hot Products

220kV Three-phase Two-winding Off-circuit Tap-changing Power Transformer The 220KV transformer ...
Full Sealed 110kV Three-phase Power Transformer with Two winding The core of 110kV power transformer ...
35KV three phase distribution transformer with low power loss 1. General of 35KV three phase ...
Electrical 220kV Two-winding On-load-changing Oil Transformer for Industries The 220KV transformer ...
HXGT Series With 35~40.5KV SF6 CIS Gas Insulated High Voltage Switchgear General structure of HXGT ...