Home Companies Wenzhou Ginri Power Automation Co., Ltd.

Three Protection Relay Monitoring Detection DVRD DC Voltage Protection

Wenzhou Ginri Power Automation Co., Ltd.
Active Member

Contact Us

[China] country

Address: No.337,Kaichuang Road,Baitawang Industrial Distrit, Beibaixiang Town,Yueqing City,Zhejiang Province,China

Contact name:

Inquir Now

Wenzhou Ginri Power Automation Co., Ltd.

Three Protection Relay Monitoring Detection DVRD DC Voltage Protection

Country/Region china
City & Province zhejiang
InquireNow

Product Details

GINRI Voltage Monitoring Relay DC Over/Under Voltage Relay DVRD

 

 

Features:

  • Compact modular size
  • DC circuit monitoring of over-and undervoltage
  • Adjustable over-and undervoltage threshold
  • Adjustable trip delay time
  • Powered by the measuring circuit
  • 2C/O contacts
  • 2 LEDs for status indication

Protective Functions

  • DC overvoltage
  • DC undervoltage

Applications

  • DC cabinet
  • Battery
  • Electric control system

 

ModelDVRD
Input circiut =measuring circuitDC supply
Rated voltageDC12V.DC24V.DC36V,DC48V
Monitoring functionsOvervoltage,undervoltage
Voltage setting range
Rated voltageundervoltageovervolatge
DC12V10-14V13-17V
DC24V20-28V26-34V
DC36V30-42V39-51V
DC48V40-56V52-68V

 

Tripping delay time0.1~15s adjustable
Voltage hysteresis3-5% fixed
Reset delay time100ms
indicatorsnormal,trip
Output contacts2C/O
Contact capacity6A,250VAC/30VDC(resistive load)
Degree of protectionIP20
Working conditions-25℃~65℃,≤85%RH,non-condensing

Mechanical

durability

1000000 cycles
Dielectric strength>2KVAC 1min
Weight130g
Dimension(HXWXD)79X23X79mm
MountingDin rail

 

 

Low voltage protection means that the low voltage protection relay is connected in parallel at both ends of the power supply. When the voltage is low, it will automatically trip to separate the circuit breaker switch. Low-voltage internship installation: low-voltage equipment such as thermal relays, fuses, and intermediate relays.

 

When the voltage of the power supply bus of the motor is reduced or interrupted and restored, the low voltage protection is usually installed on the secondary motor to prevent the motor from being automatically started at the same time. When the power supply bus voltage is low to a certain value, the low voltage protection action removes the secondary motor and restores the power supply bus voltage to a sufficient voltage to ensure the self-starting of the important motor.

Hot Products

120 Volt Overcurrent Current Balance Relay Integrative Structure For Blowers Protection function ...
Phase Unbalance Current Monitoring Relay Integrative Structure For Compressors ♦ Features -- ...
Fans current limiting relay , 40A Phase Failure Protection Relay Integrative Structure ♦ Features -- ...
Overload Current Monitoring Relay 1 NC SCR Output Contact LED Indication JDB-1 series motor ...
Unbalance Current Control Relay 220V 380V With Knob Setting Method With 4 LEDS 1 Features Integrativ...