GINRI Voltage Monitoring Relay DC Over/Under Voltage Relay DVRD

 

 

Features:

  • Compact modular size
  • DC circuit monitoring of over-and undervoltage
  • Adjustable over-and undervoltage threshold
  • Adjustable trip delay time
  • Powered by the measuring circuit
  • 2C/O contacts
  • 2 LEDs for status indication

Protective Functions

  • DC overvoltage
  • DC undervoltage

Applications

  • DC cabinet
  • Battery
  • Electric control system

 

ModelDVRD
Input circiut =measuring circuitDC supply
Rated voltageDC12V.DC24V.DC36V,DC48V
Monitoring functionsOvervoltage,undervoltage
Voltage setting range
Rated voltageundervoltageovervolatge
DC12V10-14V13-17V
DC24V20-28V26-34V
DC36V30-42V39-51V
DC48V40-56V52-68V

 

Tripping delay time0.1~15s adjustable
Voltage hysteresis3-5% fixed
Reset delay time100ms
indicatorsnormal,trip
Output contacts2C/O
Contact capacity6A,250VAC/30VDC(resistive load)
Degree of protectionIP20
Working conditions-25℃~65℃,≤85%RH,non-condensing

Mechanical

durability

1000000 cycles
Dielectric strength>2KVAC 1min
Weight130g
Dimension(HXWXD)79X23X79mm
MountingDin rail

 

 

Overvoltage protection
Overvoltage refers to any voltage whose peak value is greater than the corresponding peak value of the maximum steady state voltage under normal operation. In engineering, it refers to all dangerous voltages that can cause damage to equipment. Therefore, in the project, some overvoltages that are larger than the normal operating voltage of the equipment but insufficient to endanger the normal operation of the equipment are excluded. Overvoltages include:
(1) Transient overvoltage, with a duration of milliseconds or less, is the main protection object of the arrester.
(2) Transient overvoltage or short-time overvoltage, the duration is relatively long, generally between 0.1s and 1s.

Hot Products

GINRI Voltage Monitoring Relay DC Over/Under Voltage Relay DVRD Features: Compact modular size DC ...
GINRI Voltage Monitoring Relay DC Over/Under Voltage Relay DVRD Features: Compact modular size DC ...
GINRI Voltage Monitoring Relay DC Over/Under Voltage Relay DVRD Features: Compact modular size DC ...
GINRI Voltage Monitoring Relay DC Over/Under Voltage Relay DVRD Features: Compact modular size DC ...
GINRI Voltage Monitoring Relay DC Over/Under Voltage Relay DVRD Features: Compact modular size DC ...
GINRI Voltage Monitoring Relay DC Over/Under Voltage Relay DVRD Features: Compact modular size DC ...