Introduction:


Type E thermocouple bare wire is a commonly used thermocouple type used for temperature measurement and control. It is composed of nickel-chromium alloy (Chromel) and copper-nickel alloy (Constantan). Type E thermocouple bare wire is suitable for medium temperature ranges, typically measuring temperatures from -200°C to 900°C. This type of thermocouple has good linear characteristics and low drift, providing relatively accurate and stable temperature measurements.

E-type thermocouple bare wire is widely used in industrial control fields, including heating equipment, furnace temperature monitoring and heat treatment processes. It is also widely used in environmental monitoring, such as weather stations, greenhouses and warehousing environments. In scientific research and laboratories, E-type thermocouple bare wires are often used to measure sample temperature and conduct thermodynamic experiments.

 

Characteristic:


  • Thermocouple material: Type E thermocouple bare wire is composed of nickel-chromium alloy (Chromel) and copper-nickel alloy (Constantan). Chromel is the positive pole of the E-type thermocouple and Constantan is the negative pole.
  • Temperature range: Type E thermocouple bare wire is suitable for medium temperature ranges, typically measuring temperatures from -200°C to 900°C (-328°F to 1652°F).
  • Linear characteristics: E-type thermocouple bare wire has good linear characteristics within its operating temperature range and can provide relatively accurate temperature measurements.
  • Low drift: Type E thermocouple bare wire has low drift characteristics and can maintain relatively stable temperature measurements.

 

Advantage:


  • Widely used: Type E thermocouple bare wire is one of the most commonly used thermocouple types and is widely used in various industrial fields and laboratory environments.
  • Corrosion resistance: E-type thermocouple bare wire has good corrosion resistance to oxidizing and reducing gases, and is suitable for temperature measurement in some chemical industries and corrosive environments.
  • Fast response: E-type thermocouple bare wire has fast temperature response capability and can quickly reflect temperature changes.

 

Relevant specific parameters:


  1. Temperature range: -200°C to 900°C (-328°F to 1652°F)
  2. Thermoemf output: Varies based on temperature changes, usually in the microvolt (μV) level.
  3. Linear characteristics: has good linear characteristics.
  4. Sensitivity: Varies based on specific model and manufacturer.
Code
Wire Component of the thermocouple
+Positive leg
- Negative Leg
N
Ni-Cr-Si(NP)
Ni-Si-magnesium (NN)
K
Ni-Cr(KP)
Ni-Al(Si) (KN)
E
Ni-Cr(EP)
Cu-Ni (EN)
J
Iron (JP)
Cu-Ni (JN)
T
Copper (TP)
Cu-Ni (TN)
B
Platinum Rhodium-30%
Platinum Rhodium -6%
R
Platinum Rhodium-13%
Platinum
S
Platinum Rhodium -10%
Platinum
  • ​Standards
ASTMANSIIECDINBSNFJISGOST
(American Society for Testing and Materials) E 230(American National Standard Institute) MC 96.1(European Standard by the International Electrotechnical Commission 584)-1/2/3(Deutsche Industrie Normen) EN 60584 -1/2(British Standards) 4937.1041, EN 60584 - 1/2(Norme Française) EN 60584 -1/2 - NFC 42323 - NFC 42324(Japanese Industrial Standards) C 1602 - C 1610(Unification of the Russian Specifications) 3044

 

  • Working temperature:

 

Diameter/mmLong time WorkingShort period Working
temperature/°Ctemperature/°C
0.3,0.5350450
0.8,1.0,1.2450550
1.6,2.0550650
2.5650750
3.2750900

 

Using Occastion of Different Thermocouple
Thermocouple Type
Working Atmosphere
Working Temperature
Type K
KP
Oxidizing
-200 to +1200℃
KN
Inert
Type N
NP
Oxidizing
-200 to +1200℃
NN
Oxidizing
Type E
EP
Oxidizing
-200 to +900℃
EN
Oxidizing
Type J
JP
Oxidizing(use in high temp)
-40 to +750℃
JN
Reducing, Inert, Vacuum
Type T
TP
Oxidizing,Vacuum
-200 to +350℃
TN
Reducing, Vacuum

contact us

email:victory@dlx-alloy.com

Oem service:
Welcome customized size
We are experience factory for OEM&ODM service

 

Specific application areas:


  1. Industrial control: E-type thermocouple bare wire is widely used in industrial control fields, including heating equipment, furnace temperature monitoring, heat treatment processes, etc.
  2. Environmental monitoring: E-type thermocouple bare wire can be used for environmental temperature monitoring, such as weather stations, greenhouses and storage environments.
  3. Laboratory research: E-type thermocouple bare wire is widely used in scientific research and laboratories for measuring sample temperature, thermodynamic experiments, etc.

 

 

Q&A:


What is the temperature range of Type E thermocouple bare wire?
Answer: The temperature range of Type E thermocouple bare wire is usually between -200°C and 900°C.

 

What are the advantages of E-type thermocouple bare wire?
Answer: E-type thermocouple bare wire has the advantages of wide application, corrosion resistance and fast response.

 

What applications are type E thermocouple bare wire suitable for?
Answer: E-type thermocouple bare wire is suitable for industrial control, environmental monitoring, scientific research and laboratory applications.

Hot Products

The Thermocouple bare wire product series provides a variety of models and specifications, including ...
The Thermocouple bare wire product series provides a variety of models and specifications, including ...
The Thermocouple bare wire product line includes a variety of models (such as K-type, J-type, T-type ...
Introduction: K-type thermocouple bare wire is a commonly used thermocouple type, consisting of K...
Introduction: Type E thermocouple bare wire is a commonly used thermocouple type used for temperatur...
Introduction: Type J thermocouple bare wire is a commonly used thermocouple type used for temperatur...