VICTOR189A 0.025% Accuracy True RMS Multi-function Digital Multimeter With 55000 counts Display 1000V Fuse Protection With USB

 

Basic feature

  • The displayed reading of measurement is 55000 bytes, and basic accuracy is 0.025%.
  • Double color plastic shell to meet IP65 dustproof and waterproof grade, and can be used in harsh environment.
  • Complies with 600V CAT.IV, 1000V CAT.III safety standard
  • Current employs 11A/1000V﹠0.44A/1000V fast-felt fuse protection.
  • basic measurement function

AC voltage, DC voltage, AC current, resistance, capacity

Continuity, diode, frequency/duty ratio measurement

temperature measurement, RTD measurement, peak measurement(PEAK)

AC + frequency(AC+Hz)measurement

relative measurement(REL_%)

maximum value, minimum value, average measurement(MAX/MIN/AVG)

  • Display speed rate: twenty times/ second fast, five times/ second slow, analog bar refreshing speed: twenty times/ second as fast as possible.
  • TRMS value, measurement bandwidth 20Hz~50kHz.
  • Selectable manual or auto-range measurement.
  • Measurement data display hold (DIS_HOLD)and auto hold (AUTO_HOLD)function.
  • Peak measurement function, 1ms of peak value sample capture, which can capture spike pulse.
  • Selectable dB measurement for 1~2400Ω reference impedance.
  • Low pass filter function can improve the measurement effects of the complex waveform caused by inverter and frequency conversion motor.
  • Vocalize if the continuity measurement is below 50Ω.
  • TC measurement: K graduation, built-in temperature transmitter, auto cold- compensation, and display ℃ or ℉ for temperature.
  • Large screen allows multi-data display, showing measured value and other relevant measured information simultaneously.
  • Multi-data parameter recording function: manual recording, timing recording and is convenient to inquire the recorded data.
  • The meter is equipped with data storage with large capacity, to store as many as 2000(groups) data of field calibration. The data can be read from the meter or uploaded to the user’s PC.
  • on-line communication function
  • VICTOR189A can undertake wired communication with infrared serial port of the compatible USB connection.
  • Supports SCPI commands of industrial standard, and can realize remote control of the meter by equipment driving software.
  • the WIFI wireless communication supports two modes:
    • AP mode, namely hot mode, PC can undertake wireless communication with the meter through WIFI.
    • STA mode,namely router mode,which is separated as STA (Client)mode and STA (Server) mode. PC needs the supports from WIFI router to communicate with the meter.
  • The infrared wire communication function will conveniently help the user to get multiple data parameters by powerful, friendly man-machine interface, and make data storage, settlement and management in form of figures or tables.
ProjectVICTOR 189A
DC voltageRange50mV/500mV/5V/50V/500V/1000V
Basic accuracy±(0.025%+5dgt)
AC voltageRange50mV/500mV/5V/50V/500V/1000V
Basic accuracy±(0.7%+30dgt)
DC currentRange500uA/2000uA/20mA/200mA/2A/10A
Basic accuracy±(0.15%+10dgt)
AC currentRange500uA/2000uA/20mA/200mA/2A/10A
Basic accuracy±(0.8%+30dgt)
ResistanceRange50Ω/500Ω/5kΩ/50kΩ/500kΩ/5MΩ/50MΩ
Basic accuracy±(0.05%+5dgt)
CapacitanceRange10nF/100nF/1000nF/10uF/100uF
/1000uF/10mF/100mF
Basic accuracy±(5%+5dgt)
FrequencyRange10Hz~100KHz
Basic accuracy±(0.02%+4dgt)
ThermocoupleRangeK indexing:-200.0°C~1360.0°C
Basic accuracy±(0.5%+3°C)
RTDRangePt100:-200.0°C~800.0°C
Basic accuracy±(0.5%+3°C)
Display words55000
The measurement rateFast:20 times / sec
Slow:5 times / sec
Analog Bar graphThe faster rate:20 times / sec
Automatic / manual range
Measure the true effective value
Bandwidth50kHz
The duty ratio10%~90%
Diode test
Continuity beeper
dBm
Low pass filter
MAX/MIN/AVG
Relative value measurement
Data Hold
Auto Hold
Peak Hold
The reference junction compensation
°C/ ° F conversion
Change rate
Input impedance10MΩ
Data recordingManual record:1000 groups
Homework:1000 groups of records
Online communicationVICTOR 189A can undertake wired communication with intrared serial port of the compatible USB connection.
Support the SCPI command, can realize remote control instrument by the device driver software. The powerful function, friendly man-machine interface, the user can conveniently obtain multiple data parameters of instrument, and the data storage, processing, management, access to data is displayed in the graphical or tabular form.
Auto power-off
Display typeLCD
Backlight
Power Supply4×AA Alkaline batteries
SafetyCAT IV 600V,CAT III 1000V
Electromagnetic compatibilityIEC61326-1,Group1,Class B
Size206×97×60mm
WeightAbout500g
Standard Quantity Per Carton10pcs
Standard Carton Measurement395mm*385mm*260mm
Standard Carton Cross Weight11.3Kg

 

Technique indicators

 

measurement functionrangemeasurement rangeresolutionaccuracyremark

20Hz~

45Hz

45Hz~

65Hz

65Hz~

1KHz

1KHz~

10KHz

10KHz~

20KHz

20KHz~

50KHz

AC voltage

ACV

5V0~5.5000V0.0001V2%+800.5%+300.7%+302%+303%+605%+100

Input impedance

10MΩ / 50pF

 

Response time≤2S

50V0~55.000V0.001V2%+800.5%+300.7%+302%+303%+605%+100
500V0~550.00V0.01V2%+800.5%+300.7%+30---------------
1000V0~760.0V0.1V2%+800.5%+300.7%+30---------------

AC mili-voltage

ACmV

50mV0~55.000mV0.001mV2%+800.7%+300.7%+302%+303%+605%+100
500mV0~550.00mV0.01mV2%+800.7%+300.7%+302%+303%+605%+100

AC current

ACA

10A0~10.000A0.001 A2%+401.5%+203%+80----------

Voltage Drop

<0.1 V/A

Response time≤3S

5A0~5.5000A0.0001 A2%+401%+203%+80----------

AC mili-current

ACmA

50mA0~55.000mA0.001mA1.5%+800.5%+301%+302%+60-----

Voltage Drop

<4 mV/mA

Response time≤3S

500mA0~500.00mA0.01 mA1.5%+800.5%+301%+302%+60-----

AC micro-current

ACuA

500uA0~550.00uA0.01uA1.5%+800.5%+301%+302%+60-----

Voltage Drop

0.11 mVuA

Response time≤3S

5000uA0~5500.0uA0.1uA1.5%+800.5%+301%+302%+60-----
ULF   2%+100

2%+60 (4)

-6%-80

---------- 
 

 

Note : ① <20kHz adapts to 5~110% range,≥20kHz adapts to 10~110% range.

② 50mV,500mV,1000V range adapt to 10~110% range.

  • 50mV,500mV from 30Hz above.
  • Communication crest factor can reach 3.0 in full scale.

Hot Products

Large Lcd Display Analog VICTOR Digital Multimeter 1000V 10A 200MΩ VC3021 Analog Multimeter Large ...
VICTOR 7244 High Accuracy 10A Analog Digital Multimeter 500V Lcd Display Overview This is an analog ...
0.025% Accuracy 55000 Counts VICTOR Digital Multimeter 1000V Fuse Protection VICTOR189A 0.025% ...
Portable Commercial Electric Analog Multimeter Tester For Small Current Circuits VICTOR 3010 /3021 ...
Plastic Socket Tester VICTOR Digital Multimeter EU US Plug Breaker VICTOR 469C and 469D Socket ...
Handheld Smart Auto Range Digital Multimeter Continuity Test Anti Burning VICTOR 85B Digital ...