IP65 22kw 30hp VFD Variable Frequency Drive Vector Control

Country/Region china
City & Province shenzhen
Categories Inverters & Converters
InquireNow

Product Details

 

22kw 30hp variable frequency drive VFD AC DRIVE INVERTERS vector control

 

Product Advantage

 

1. Optimized external installation and internal structure and independent air flue design, fully enclosed electrical space design.


2. Output automatic voltage regulation function (AVR), automatically adjust the output pulse width to eliminate the influence of the grid change on load.


3. Built-in PID regulation function to facilitate the realization of closed loop control of the temperature, pressure and flow, and reduce the cost of the control system.


4. Standard MODBUS communication protocol. Easy to achieve the communication between PLC, IPC and other industrial equipments.

 

ItemSpecifiation
InputInuput Voltage

1phase/3phase 220V:200V~240V

3 phase 380V-480V:380V~480V

 Allowed Voltage fluctuation range-15%~10%
 Input frequency50Hz / 60Hz,fluctuation less than 5%
OutputOutput Voltage3phase:0~input voltage
 Overload capacity

General purpose application:60S for 150% of the rated current

Light load application:60S for 120% of the rated current

ControlControl mode

V/f control

Sensorless flux vector control without PG card(SVC)

Sensor speed flux vector control with PG card (VC)

 Operating modeSpeed control,Torque control(SVC and VC)
 Speed range

1:100 (V/f)

1:200( SVC)

1:1000 (VC)

 Speed control accuracy

±0.5% (V/f)

±0.2% (SVC)

±0.02% (VC)

 Speed response

5Hz(V/f)

20Hz(SVC)

50Hz(VC)

 frequency range

0.00~600.00Hz(V/f)

0.00~200.00Hz(SVC)

0.00~400.00Hz(VC)

 Input frequency resolution

Digital setting: 0.01 Hz

Analog setting: maximum frequency x 0.1%

 Startup torque

150%/0.5Hz(V/f)

180%/0.25Hz(SVC)

200%/0Hz(VC)

 Torque control accuracy

SVC:within 5Hz10%,above 5Hz5%

VC:3.0%

 V/f curve

V / f curve type: straight line, multipoint, power function, V / f separation;

Torque boost support: Automatic torque boost (factory setting), manual torque boost

 Frequency giving ramp

Support linear and S curve acceleration and deceleration;

4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s

 DC bus voltage control

Overvoltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault;

 

Undervoltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure

 

VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip;

VdcMin control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump undervoltage fault

 Carrier frequency1kHz~12kHz(Varies depending on the type)
 Startup method

Direct start (can be superimposed DC brake); speed tracking start

 Stop methodDeceleration stop (can be superimposed DC braking); free to stop
Maincontrol functionJog control, droop control, up to 16-speed operation, dangerous speed avoidance, swing frequency operation, acceleration and deceleration time switching, VF separation, over excitation braking, process PID control, sleep and wake-up function, built-in simple PLC logic, virtual Input and output terminals, built-in delay unit, built-in comparison unit and logic unit, parameter backup and recovery, perfect fault record,fault reset, two groups of motor parametersfreeswitching, software swap output wiring, terminals UP / DOWN
FunctionKeypadLED Digital keyboard and LCD keypad(option)
Communication

Standard:

MODBUS communication

CAN OPEN AND PROFINET( IN DEVELOPMENT)

PG cardIncremental Encoder Interface Card (Differential Output and Open Collector), Rotary transformer Card
Input terminal

Standard:

5 digital input terminals, one of which supports high-speed pulse input up to 50kHz;

2 analog input terminals, support 0 ~ 10V voltage input or 0 ~ 20mA current input;

Option card:

4 digital input terminals

2 analog input terminals.support-10V-+10V voltage input

Output terminal

standard:

1 digital output terminal;

1 high-speed pulse output terminal (open collector type), support 0 ~ 50kHz square wave signal output;

1 relay output terminal(second relay is an option )

2 analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V voltage output;

Option card: 4 digital output terminals

ProtectionRefer to Chapter 6 "Troubleshooting and Countermeasures" for the protection function
EnvironmentInstallation locationIndoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt.
Altitude0-3000m.inverter will be derated if altitude higher than1000m and rated output current will reduce by 1% if altitude increase by 100m
Ambient temperature-10°C~ +40°C,maximum 50°C (derated if the ambient temperature is between 40°C and 50°C)Rated output current decrease by 1.5% if temperature increase by 1°C
HumidityLess than 95%RH, without condensing
VibrationLess than 5.9 m/s2 (0.6 g)
Storage temperature-20°C ~ +60°C
OthersInstallationWall-mounted, floor-controlled cabinet, transmural
Protection levelIP20
cooling methodForced air cooling
EMCCE ROHS

Internal EMC filter

Complies with EN61800-3

Category C3

3rd Environment

 

Replace famous brands vfd in general application.

 

 

VEIKONG VD500 application picture:


 
23 Group Drive protection function setting
P23.00DC Bus voltage control option

Ø Unit’digit :Overvoltage stall control
0:overvoltage stall disabled
1:overvoltage stall enabled
2:overvoltage stall enabled self-adjustable

Ø The over-voltage stall function limits the amount of power generated by the motor by extending the deceleration time or even increasing the speed, avoiding over-voltage on the DC side and reporting over-voltage faults
Ten’unit:Undervoltage stall control
0:undervoltage stall disabled
1:Undervoltage stall(decelerate to zero speed and be in standby mode,after power restoring ,it will run again automatically)
2: Undervoltage stall deceleration(decelerate to zero and stop)

Ø The undervoltage stall function reduces the motor power consumption or reduces the power consumption of the motor or turns it into a power generation operation to avoid the undervoltage fault on the DC side.

Ø The undervoltage stall function is used when the input power supply quality is poor (the power supply voltage fluctuates downward or the sporadic short power is suspended), and it is necessary to keep the inverter running as much as possible.

01
P23.01Overvoltage stall threshold220V Level: 320V~400V
380V Level: 540V~800V
480V Level:650V~950V
Depend
P23.02Undervoltage threshold220V level: 160V~300V
380V level: 350V~520V
480V level: 400V~650V
Depend
P23.03Overvoltage stall ratio0~10.01.0
P23.04Undervoltage stall ratio0~20.04.0
P23.05Undervoltage trip threshold220V Level:160V~300V
380V Level:350V~520V
480V Level:400V~650V
Depend
P23.06Undervoltage fault detecting time0.0s~30.0s1.0s
P23.07Rapid current limit0:Disabled
1:Enabled
1
P23.10Over-speed detection value0.0%~120.0% maximum frequency120.0%
P23.11Over-speed detection time0.0s~30.0s0.:shielding1.0s
P23.12Detection value of too large speed deviation0.0%~100.0%(motor rated frequency)20.0%
P23.13Detection value of too large speed deviation

0.0s~30.0s

0.0:shielding

0.0s
P23.14Input phase loss detection time

0.0s~30.0s

0.0:forbidden

8.0s
P23.15Output phase loss inbalance detecting0%~100%30%
P23.18Fault protection action selection 1Unit’s digit : input phase loss
0: coast to stop
1: Emergent stop
2: Stop as per stop mode
3: Continue to Run
Ten’unit: user self-defined fault 1
same as Unit’s digit
Hundred’unit: user self-defined fault 2
same as Unit’digit
Thousand’s unit: communication fault
same as unit’s digit
0000
P23.19Fault protection action selection 2Unit’s digit: motor overload
0: Coast to stop
1: Emergent stop
2: Stop as per stop mode
3: Continue to run
Ten’unit: motor overheat
same as unit’digit
Hundred’unit: too large speed deviation
same as unit’digit
Thousand’s unit: motor over speed
same as Unit’digit
0000
P23.20Fault protection action selection 3Unit’s digit: PID feedback lost during running
0: Coast to stop
1: Fast stop
2: Stop as per stop mode
3: Continue to run
Ten’unit: Reserved
same as unit’digit
Hundred’unit: reserved
same as unit’digit
thousand’unit: reserved
same as unit’digit
0000
P23.21Fault protection action selection 4Unit’s digit: output phase loss
0: Coast to stop
1: Fast stop
2: Stop as per stop mode
Ten’unit: EEPROM fault
0: Coast to stop
1: Fast stop
2: Stop as per stop mode
3: Continue to run
Hundred’s unit: PG card fault(reserved)
0: Coast to stop
1: Fast stop
2: Stop as per stop mode
3: Continue to run
Thousand’s unit: off load fault
0: Coast to stop
1: Fast stop
2: Stop as per stop mode
3: Continue to run
0000
P23.24Fault resetDefine as per bit:
bit0-undervoltage;bit1- inverter overload
bit2-inverter overheat ;bit3-motor overload
bit4-motor overheat;bit5-user’fault 1
bit6- user’fault 2; bit7~15 reserved
0
P23.25Fault source for auto resetDefine as per bit:
bit0-overcurrent during acceleration;bit1-overcurrent during deceleration
bit2-overcurrent during constant speed;bit3-over voltage during acceleration
bit4-overvoltage during deceleratoin;bit5-overvoltage during
bit6-inverter undervoltage;bit7-input phase loss
bit8-inverter overload;bit9-inverter overheat
bit10-motor overload;bit11-motor overheat
bit12-user’fault 1;bit13-user’fault 2
bit14-Reserved;bit15-Reserved
0
P23.26Fault auto Reset times0~990
P23.27Numberic output Action at fault reset0:Disabled
1:Enabled
0
P23.28Interval time of fault auto reset0.1s~300.0s0.5s
P23.29Fault auto reset times clearing time0.1s~3600.0s10.0s
P23.30Continuing Running frequency selection when trip0:Run at current frequency
1:Run at setted frequency
2:Run at upper limite frequency
3:Run at lower limit frequency
4:Run at abnormal back-up frequency
0
P23.31Abnormal back-up frequency

0.0%~100.0%(maximum frequency )

 

 

5.0%
 

 

Hot Products

Vfd 4kw 5.5kw variable frequency drive 220v 380v single phase three phase Product Advantage Compact ...
220V 380v 7.5KW 10HP VFD with vector control ac drive frequency inverter Product Advantage 1. Our ...
110kw 150hp variable frequency drive vector control for heavy load​ Product Advantage 1. Energy ...
22kw 30hp variable frequency drive VFD AC DRIVE INVERTERS vector control Product Advantage 1. ...
30kw 40hp 220v 380v variable frequency drive VFD three phase single phase VEIKONG VFD500 Technical ...
45kw 60hp ac drive inverter vfd for pump fan air compressor vfd 1, With inside EMC C3 filter and ...