Unbalance Load Parallel Redundant Ups System High Capacity Comprehensive Protection

Country/Region china
City & Province shenzhen guangdong
Categories Uninterrupted Power Supply (UPS)
InquireNow

Product Details

Self-Diagnosis Advanced Modular UPS System With Comprehensive Protection

 

 

Brief Information:

 


CNM330 series is modular online UPS for sensitive equipment. The single cabinet power rating covers from 10KVA to 300KVA which delivers the best of combination of reliability, hot-swappable and flexibility. With the latest IGBT three-level technology and DSP control, CNM330 achieves a high input power factor, low THDi Modular design with N+X redundancy and online hot swapping ,easy to expand the capacity Full DSP control of high stability, reliability and safety Integrated IGBT module with improved performance and reduced size
 

Excellent Self-Diagnosis Performance:

 

  • Monitor inverter, rectifier
  • Monitor inverter fuse
  • Monitor battery
  • Monitor magnetic’s temperature
  • Monitor every fan failure
  • Monitor every switch status


Application:

  •  
  • Application IDC(Internet Data Center)
  • Computing center
  • ISP (Internet Service Provider )
  • Telecom , Finance, bank and securities , Tax
  • Hospital system , industrial automation
  • Precision equipment, etc.

 


Technical Specifications:

 

 

ModelCNM330 20-300KVA
Capacity20-300KVA
Main Input 
Input Voltage380V/400V/415V
Input Frequency Range50/60Hz
Power FactorFull load>0.99 ,Half load >0.98
THDiTHDi<3%
Input Power Soft-start Function5-30s settable
Input Voltage Ranges228V-476V;-20%~25% at Full load ; linear derating at -25% ~- 40%; can take 70% load at -40%
Frequency Range40-70HZ
Battery
Battery Voltage±240VDC(Default),12V Battery 30~40pcs can be choose
Charge Voltage Accuracy±1%

 

 

 

Bypass
Bypass Input Voltage380/400/415VAC 3-phase 4-wire
Voltage RangeDefault value is -20%~+15%; -40%, -30%, -10% ~ +10%, +15% , other ranges can be set via software
Overload Capacity

Long term at 135% rated load ,150%<load<180% more than 10 min,

load>1000% 100ms

 

 

 

Output
Inverter Output Voltage380/400/415VAC 3-phase 4-wire
Voltage Accuracy±0.5% ( balanced load ) , ±1% ( unbalanced load )
THDVTHDV<1% (linear load) , THDV<3% (nonlinear load)
Power Factor0.9
Three Phase Angle Accuracy120°± 0.5°
Current Crest Ratio3:1
Overload Capacity110%1h,125%10mins,150%1mins,>150%200ms
Transfer Time0ms,15ms (Eco Mode)
 

 

 

 

System
Frequency50Hz/60Hz (Settable)
Mains Synchronization Range±2Hz(Default value), adjustable with step of 0.5Hz within range of +/- 0.5Hz - 3Hz
Protection LevelIP20
Operation Temperature0-40ºC
Storage Temperature-25ºC~70ºC ( without battery)
Humidity0-95% (no-condensing)
Noise(dB)55-62dB,Adjusted with load
Weightmodule:PM2020KVA power module : 35KG
module:PM3030KVA power module : 35KG
module:PM4040KVA power module : 35KG
Dimension (W x D x H)mm3 module cabinet600X900X1135
5 module cabinet(5 battery cabinet option)600X1100X2070/
6 module cabinet600X900X1535
10 module cabinet900X900X2080
power module440X650X132(3U)(10KVA/20KVA/30KVA)


(Optional South America 208V must be derating use)

 

 

 

Hot Products

Data Center Power Modular UPS System Standard Module With EMI Filter And STS Brief Introduction: ...
Large Data Record Power Modular UPS System With Easy Maintenance 300KVA Brief Information: CNM330 ...
High Overload Capacity Modular UPS System With Auto - Calibration 300KVA Brief Information: CNM330 ...
30KVA to 300KVA Low Audible Noise Modular UPS System For Unbalancing Load Brief Information: CNM330 ...
Self-Diagnosis Advanced Modular UPS System With Comprehensive Protection Brief Information: CNM330 ...
Sine Wave And PF = 1 Modular UPS System With Low Input THDI And Unity PF Brief Information: CNM330 ...