Home Companies Guangzhou Rongtao Medical Tech LTD.

Hitachi HI VISION Ultrasound Machine Repair Replace Cell Board Preirus Image Blurred And Report Error

Guangzhou Rongtao Medical Tech LTD.

Contact Us

[China] country

Trade Verify

Address: Room 1705,Office Building B1,Wanda Plaza,No.2707,Kaichuang Road,Guangzhou,Guangdong,China

Contact name:MileyZhu

Inquir Now

Guangzhou Rongtao Medical Tech LTD.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Hitachi HI VISION Ultrasound Machine Repair Replace Cell Board Preirus Image Blurred And Report Error

Country/Region china
City & Province guangzhou guangdong
Categories Rubber Product Making Machinery Parts
InquireNow

Product Details

 

Hitachi HI VISION Preirus Image Blurred And Report Error Ultrasound Machine Repair Replace Cell Board

 

1. Repair time: 2-4 days
2. Warranty: 60 days
3. Fault phenomenon:
Image Blurred And Report Error

 

Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range.

 

 

Other ultrasound parts related that we can offer:

 

 

BrandCompatible SystemDescription
HitachiEUB-5500CW Doppler board EZU-ST5
HitachiEUB-5500MAP-A WU8012-2
HitachiEUB-5500MAP WB8002-A
HitachiEUB-5500Control Panel KB319385-E6
HitachiEUB-5500PCB CZ08AB-S12
HitachiEUB-5500power board P.S. HM-071CE 7216682B HM-071K
HitachiEUB-5500DBF board CZ04AM-S11 CZ04AB-S10
HitachiEUB-6000Control Panel KA182319C
HitachiEUB-6000AC power board HM750D
HitachiEUB-6000BWDSC board CU6045-B EF360518
HitachiEUB-6500TI board CZF4AB-S11 CZ04AG-S11
HitachiEUB-6500DBF-B CUH003-S11
HitachiEUB-6500/EUP7500CW Doppler board CU8019-S12 UOF672

 

 

 

Knowledge point

 

Importance of maintaining ultrasound machine

 

Paying attention to preventive maintenance is the basic requirement of medical equipment engineers and technicians. Perform regular checks on equipment to ensure safe and effective operation of equipment, reduce downtime and save maintenance costs. Eliminate minor faults and avoid causing major faults to affect the normal operation of the hospital. Attention should be paid to any abnormality that occurs during the operation of the equipment. Sometimes a small abnormal phenomenon may be a precursor to a failure. If it is not checked, it may cause a greater failure and bring unnecessary losses to the hospital. Do not let the equipment work with faulty. Do not wait until the equipment is completely paralyzed before repairing. Routine maintenance can extend the service life of the equipment and improve economic efficiency.

 

 

Maintenance advantages of ultrasound boards

 

1. Experience of maintenance for over 10 years

  • Consistently superior quality and after-sales service
  • Free Prejudge and No Diagnostic Fees
  • Over 10,000 pcs of ultrasonic parts in stock, available for exchange/outright sale
  • Less than 3% warranty return claims, earn good reputation

 

 

Repair Service Advantages:

 

1. Free Prejudge and No Diagnostic Fees

2. Fast 2-5 days turn-around repair cycle, 95% on-time delivery of repairs

3. Test video after fixed available

4. Up Front Quote/ Pricing ,we always offer a quote up front with clear pricing so you can be sure what to expect

5. Less than 3% warranty return claims, earn good reputation

6. Save 50%-80% comparing to outright purchase

7. 60 Day Warranty on all repairs

8. Certified Quality Control process you can count on

9. We repair medical parts that the manufacturer’s no longer service

10. Major in repair 50 popular & mainstream ultrasound systems, covering global leading brands (GE, Hitachi Aloka, ,Siemens,Toshiba,Biosound---)

 

 

Basic components of color Doppler ultrasound

 

1. Monitor (CRT/LCD)

2. Control panel (Touch screen, Numeric keyboard)

3. Front end (Probe interface board, FEC, AIM, CB)

4. Back end (Graphics card, DSC, Uavio, Mainboard )

5. Power supply(AC,PSA)

6. CD driver

7. Probe

 

 

Common failures of color Doppler ultrasound

 

1. Control panel failure

2. System software, application software failure

3. Back end failure

4. Power failure (Main power supply, Low-voltage power supply, High-voltage power supply)

5. Transducer Probe failure

6. Front-end failure (Interface board, Transmitter, Receiver, Control, VIDEO, Front-end connection)

7. Display failure (Display, Workstation, Touch screen)

8. Failure caused by external environment

 

 

 

Precautions for Maintenance

 

Before delivery, we'd like to confirm the below details of your defective ultrasonic board.

 

Have your board ever repaired? ( Better to be never repaired)

Is the board original in complete condition?

What's the detailed faults? ( Send me fault description, fault image or video)

 

Your answers will help our repair engineers team to prejudge whether it's repairable.

 

Hot Products

CX50 Power Supply board 453561375144 Medical Solutions Repair 1. Part number: 453561375144...
Hitachi HI VISION Preirus Image Blurred And Report Error Ultrasound Machine Repair Replace Cell ...
Bisound Biosound MyLab series CPU Mainboard 9501361000 Medical Equipment Ultrasound Repair 1. Part ...
Hitachi ARIETTA 60 Can Not Start Up Ultrasound Machine Repair Replace BE Board 1. Repair time: 2-4 ...
GE Logiq E9 BEP Power 5393800-3 Ultrasound Machine Repair Medical Imaging Device 1. Repair time: 2-4 ...
GE Voluson S6/S8/P8 CPS Power Supply 5393431 Ultrasound Board Maintenance Repair GE Voluson S6/S8/P8 ...