IU22 Probe Frequency Ultrasound Machine Repair Diagnostic Supplies

Country/Region china
City & Province guangzhou guangdong
Categories Rubber Product Making Machinery Parts
InquireNow

Product Details

  IU22 Probe Frequency Ultrasound Repair

IU22 System Reports Error

 

 

 

Fault phenomenon

 

After pressing the power button, the screen of the IU22 ultrasound device does not display an image.

 
 

 

 


 

 

 

Fault analysis and Troubleshooting

 

The device's non-display failure is roughly divided into two categories: the display or the display cable is faulty; the computer host fails to start normally. After the device is turned on, you can feel the vibration of the host when it is running. Press the shutdown button to shut down normally and judge the host computer to be normal. The fault may be a fault in the monitor or the monitor power cord.
Remove the device monitor, connect a computer monitor with DVI interface, the image display is normal, and finally determine the monitor failure. Disassemble the monitor, detect that the high-voltage board of the monitor is burnt out, and the front-level power supply of the driver board burns through, and the equipment is used normally after maintenance.

 
 

Ultrasound parts that we can repair:

 

 

Repair List of Featured Ultrasonic Board & Assy
BrandSystemDescriptionPart Number
GELogiq P5CPU mainboard5168431
GELogiq P6CPU mainboard 
GELogiq E9/vivid E9GFI25161631
GEVoluson E6/Voluson E8RSRKTI301394-2/KTI196357
GEVoluson E6/Voluson E8RFI/ RFI21b BoardKTI300614/KTI302197-6
GEVoluson S6/S8/P8BF645396937-2
GEVoluson S6/S8/P8RFS board5364098-2/5364098-3
GEVoluson S6/S10/P8BF192 board5357234
AlokaAlpha 5mainboardEP493700DD
AlokaAlpha 6RX Beam FormerEP555501AA
AlokaAlpha 6CW boardEP555700
AlokaAlpha 6CPU mainboardEP537000/EP563000
AlokaAlpha 6TX/RXEP555300
AlokaAlpha 6/Alpha 7DOMEP550000AA
AlokaAlpha 10RX Beamformer boardEP531800CE
AlokaAlpha 10wave generator BoardEP495000HH/EP495000HJ/EP495000FF
HitachiF37TX/RSEP557400/EP557300
HitachiF37mainboardEP575700BC/EP560800
AlokaF75USP boardEP556600
AlokaF75Cell BoardEP558800
HitachiHI VISION AviusRDBF board7513907A/7513612
HitachiArietta 60CELLEU-9160C
HitachiArietta 70TXEP572300AA
HitachiArietta 70CELL 
HitachiNoblusCELL 
HitachiNoblusCONT-B 
HitachiAscendusCELL7352830A
SiemensX150/G40BE10131804
SiemensX300BE 2.0/BE 3.0/BE 7.510131990
SiemensX700BE10136465
SiemensX700RC10136467
SiemensX700TI11014292
SiemensAntaresBE7472421
SiemensAntaresCB7288504
SiemensS2000RM30010852163
SiemensS2000 high version/S3000RM30110854749
iU22/iE33EMB excelsior motherboard453561419431/453561382231/453561419431
iU22/iE33UMB Unified Motherboard453561254492/453561360251
HD15ACB acquisition control board453561197145/453561197144
HD15AIM board4.53561E+11
CX50control panel4.53562E+11
CX50mainboard453561368033/453561622163/453561495832
Affiniti 70ACQ acquisition control board 
EPIQ 5/EPIQ 7ACQ Acquisition Module board453561734844/453561704246
BiosoundMylab SeriesCPU mainboard9501361000
ToshibaAplio 300/400/500mainboardPM30-38696
ToshibaAplio 500RXywm2056*a
ToshibaXario 200TXPM30-32732-1
ToshibaXario 200RXPM30-32733-1
Remarks
1.The repair cycle is within 3-5 days.
2.Warranty after fixed:60 days.
3. Kindly send us the estimated main faults (better to have image) for our engineer to prejudge.
4.Package price is available if repair 3 pcs or more at one time.
5.Extra discount for VIP partners.
6.You could have different part No.under same description.

Hot Products

HD15 System Reports Error The parts with high failure rate&available in stock of this machine: 1.T/R ...
HD11 System Reports Error The parts with high failure rate&available in stock of this machine: 1.T/R ...
IU22 Cow Scanning Equipment Repair IU22 System Reports Error Fault phenomenon The screen of the IU22 ...
IE33 Ultrasound Diagnostic System Repair IE33 System Reports Error The parts with high failure rate...
IU22 Probe Frequency Ultrasound Repair IU22 System Reports Error Fault phenomenon After pressing the ...
EPIQ7 Ultrasound Machine Maintenance EPIQ7 System Reports Error Failure phenomenon The EPIQ 7 ...