 Simens X700 heart ultrasound machine Repair

Simens X700 System Reports Error

 

 

 

Fault Phenomenon

 

The self-check before the device is used indicates that the flow sensor test fails.

 

 

Fault analysis and Troubleshooting

 

Analyze the factors that cause the flow sensor test failure

 

1.Insufficient air source pressure does not meet the test standard;

2.The outgoing call box is faulty;

3.The gas module is faulty.

4.Internal circuit boards of the ventilator, such as PC1772 and PC1771, are faulty.

 

 

Check the air source pressure is normal, eliminate the problem of air source. Further check the outgoing box. After replacement, the power-on self-test passes, indicating that the fault is in the outgoing box.

Siemens ventilator is an integrated exhalation box, which allows high-temperature disinfection. However, high-temperature and high-pressure sterilization equipment in domestic hospitals cannot meet the sterilization level of exhalation box, so the high-temperature and high-pressure sterilization is basically abandoned in China.

If the disinfection method is not correct, it will often cause the failure of the exhalation box. The key points of cleaning and disinfecting exhalation box are as follows: First, do a good job of cleaning and disinfecting the exhalation box before sending it to the supply room for sterilization. The tubes of the exhalation box will be stained with the patient's body fluid, so the tubes of the exhalation box can be washed clean by cleaning and disinfection. The common method is to soak the tubes with diluted hypochlorous acid disinfectant, and then send them to the supply room for sterilization after cleaning and disinfection.

 

Secondly, after the cleaning, disinfection and sterilization work in the supply room, the exhalation box must be dried. Only the use of the dried exhalation box can ensure safety, otherwise it is very easy to damage the exhalation box.

 

 

 

 

 

 

Ultrasound parts that we can repair:

 

 

Repair List of Featured Ultrasonic Board & Assy
BrandSystemDescriptionPart Number
GELogiq P5CPU mainboard5168431
GELogiq P6CPU mainboard 
GELogiq E9/vivid E9GFI25161631
GEVoluson E6/Voluson E8RSRKTI301394-2/KTI196357
GEVoluson E6/Voluson E8RFI/ RFI21b BoardKTI300614/KTI302197-6
GEVoluson S6/S8/P8BF645396937-2
GEVoluson S6/S8/P8RFS board5364098-2/5364098-3
GEVoluson S6/S10/P8BF192 board5357234
AlokaAlpha 5mainboardEP493700DD
AlokaAlpha 6RX Beam FormerEP555501AA
AlokaAlpha 6CW boardEP555700
AlokaAlpha 6CPU mainboardEP537000/EP563000
AlokaAlpha 6TX/RXEP555300
AlokaAlpha 6/Alpha 7DOMEP550000AA
AlokaAlpha 10RX Beamformer boardEP531800CE
AlokaAlpha 10wave generator BoardEP495000HH/EP495000HJ/EP495000FF
HitachiF37TX/RSEP557400/EP557300
HitachiF37mainboardEP575700BC/EP560800
AlokaF75USP boardEP556600
AlokaF75Cell BoardEP558800
HitachiHI VISION AviusRDBF board7513907A/7513612
HitachiArietta 60CELLEU-9160C
HitachiArietta 70TXEP572300AA
HitachiArietta 70CELL 
HitachiNoblusCELL 
HitachiNoblusCONT-B 
HitachiAscendusCELL7352830A
SiemensX150/G40BE10131804
SiemensX300BE 2.0/BE 3.0/BE 7.510131990
SiemensX700BE10136465
SiemensX700RC10136467
SiemensX700TI11014292
SiemensAntaresBE7472421
SiemensAntaresCB7288504
SiemensS2000RM30010852163
SiemensS2000 high version/S3000RM30110854749
 iU22/iE33EMB excelsior motherboard453561419431/453561382231/453561419431
 iU22/iE33UMB Unified Motherboard453561254492/453561360251
 HD15ACB acquisition control board453561197145/453561197144
 HD15AIM board4.53561E+11
 CX50control panel4.53562E+11
 CX50mainboard453561368033/453561622163/453561495832
 Affiniti 70ACQ acquisition control board 
 EPIQ 5/EPIQ 7ACQ Acquisition Module board453561734844/453561704246
BiosoundMylab SeriesCPU mainboard9501361000
ToshibaAplio 300/400/500mainboardPM30-38696
ToshibaAplio 500RXywm2056*a
ToshibaXario 200TXPM30-32732-1
ToshibaXario 200RXPM30-32733-1
Remarks
1.The repair cycle is within 3-5 days.
2.Warranty after fixed:60 days.
3. Kindly send us the estimated main faults (better to have image) for our engineer to prejudge.
4.Package price is available if repair 3 pcs or more at one time.
5.Extra discount for VIP partners.
6.You could have different part No.under same description.


Hot Products

Toshiba Aplio 400 Vascular Therapy Ultrasound Maintenance Toshiba Aplio 400 System Reports Error The ...
Toshiba Aplio 500 Envisor Ultrasound Maintenance Toshiba Aplio 500 System Reports Error The parts ...
Simens X150 Medical Equipment Assemble Repair Simens X150 System Reports Error Siemens ventilator ...
Siemens X300 System Reports Error Fault Phenomenon When using the hollow pressure machine suddenly ...
Simens X700 heart ultrasound machine Repair Simens X700 System Reports Error Fault Phenomenon The ...
Toshiba Xario 100 Medical Monitoring Equipment Repair Toshiba Xario 100 System Reports Error The ...