Home Companies Guangzhou Rongtao Medical Tech LTD.

GE RIC5-9-D 4D Probe Motor Repair Motor Control Failures

Guangzhou Rongtao Medical Tech LTD.

Contact Us

[China] country

Trade Verify

Address: Room 1705,Office Building B1,Wanda Plaza,No.2707,Kaichuang Road,Guangzhou,Guangdong,China

Contact name:MileyZhu

Inquir Now

Guangzhou Rongtao Medical Tech LTD.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

GE RIC5-9-D 4D Probe Motor Repair Motor Control Failures

Country/Region china
City & Province guangzhou guangdong
Categories Other Switches
InquireNow

Product Details

GE RIC5-9-D 4d Probe 3D/4D Motor Repair Motor Control Failures/Diagnostic Medical Device Service

 

 

Motor control failures

 

If the array stops moving or gets stuck, the motor control function has failed and may need to be repaired or replaced.

Solution

Motor repair 

 

 

 

 

 

Other hot GE models we can repair:

 

GEC1-5-D
GEC1-5-RS
GE4C
GE4C-RS
GE4C-A
GE4C-D
GE4C-SC
GEE8C/E8C-RS
GEE8CS
GERIC5-9-D
GE3CRF-D
GEC1-6-D
GERAB4-8-RS
GERAB2-5-RS
GE6S-RS
GE12L-RS
GE3SC-RS
GEL6-12-RS
GE11L
GE11L-D
GE12L-RS
GE8C
GE3S
GE3S-RS
 

 

 

 

Common ultrasound Probe Damage(Specialty 3D/4D Volume probes)

 

Common ultrasound probe damageSolutions
Lens cap damageLens cap replacement
Fluid and oil leaksLens cap replacement, oil reservoir repair and replacement
Cable cutsCable patches, possible cable replacement
Inoperative steeringMotor repair
Connector housing electrical damageMinor electrical repairs, pin module replacement
Weak or dead elements, dropouts in an imageArray ball replacement, oil reservoir repair and replacement

 

 

 

Warnings and cautions of ultrasonic probe

 

The ultrasonic probe is a valuable device. It must be careful in the process of use. Avoid dropping, impact, or abrasion to transducers.

When installing or removing the probe, first switch off the power and then operate it carefully.

Avoid rapid and extreme temperature changes, as well as lengthy exposure to direct sunlight or a strong ultraviolet light source.

Do not use sharp objects to penetrate the acoustic lens.Once the acoustic lens is damaged, the coupling gel is easy to enter the interior of the probe and damage the piezoelectric element.

Do not soak transducer in any liquid above the recommended level as stated in the user manual for your system, please operate according to the manufacturer's instructions, otherwise it will lead to circuit failure or even burn out.

Do not disinfect at high temperature, because the probe is equipped with piezoelectric ceramics, high temperature will weaken the effect.

Before use, carefully check whether the housing and cable are damaged, so as to prevent the probe from high voltage injury.

After the probe is used, the residual coupling gel on the probe must be wiped clean to prevent rats or other animals from gnawing the lens.



Hot Products

GE RIC5-9-D 4d Probe 3D/4D Motor Repair Motor Control Failures/Diagnostic Medical Device Service ...
GE RIC5-9-D 4d Probe 3D/4D Dome Replacement Oil And Sealing/Diagnostic Medical Device Service We ...
Probe Repair L12-5 For Array Replacement Ultrasound Transducer We provide repair service on most ...
3D 4D Probe Repair GE RAB-6-D Transducer Abnormal Image With Air Bubble Repair time: 2-5 days ...
3D/4D Probe Dome Replacement Oil and sealing GE RIC6-12-D Array replacement We provide repair ...
Repair Service GE 4C-RS For Array Strain Relief Housing Replacement Crystal Damage We provide repair ...