Home Companies Guangzhou Rongtao Medical Tech LTD.

Cypress 4C1 Convex Ultrasound Transducer Probe Abdominal Vascular Hospital

Guangzhou Rongtao Medical Tech LTD.

Contact Us

[China] country

Trade Verify

Address: Room 1705,Office Building B1,Wanda Plaza,No.2707,Kaichuang Road,Guangzhou,Guangdong,China

Contact name:MileyZhu

Inquir Now

Guangzhou Rongtao Medical Tech LTD.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Cypress 4C1 Convex Ultrasound Transducer Probe Abdominal Vascular Hospital

Country/Region china
City & Province guangzhou guangdong
Categories Roller Bearings
InquireNow

Product Details

Cypress 4C1 Convex Ultrasound Transducer Probe Abdominal Vascular Applications Hospital Used

 

Siemens 4C1 Convex Ultrasound Transducer Probe


1. Type: convex
2. Frequency: 1.0-4.00 MHz
3. Compatible system:Cypress
4. Application: Adult Abdominal, OB/GYN, Fetal Heart, and Abdominal Vascular
5. Condition: original, in good working condition
6. With 60 days warranty

 

 


 

 

Knowledge point:

 

 

Elastography (ultrasound elasticity imaging)

 

Ultrasound is also used for elastography, which is a relatively new imaging modality that maps the elastic properties of soft tissue.This modality emerged in the last two decades. Elastography is useful in medical diagnoses as it can discern healthy from unhealthy tissue for specific organs/growths. For example, cancerous tumors will often be harder than the surrounding tissue, and diseased livers are stiffer than healthy ones.

 

 

Interventional ultrasonography

 

Interventional ultrasonography involves biopsy, emptying fluids, intrauterine Blood transfusion (Hemolytic disease of the newborn).

  • Thyroid cysts: The high frequency thyroid ultrasound (HFUS) can be used to treat several gland conditions. The recurrent thyroid cyst that was usually treated in the past with surgery, can be treated effectively by a new procedure called percutaneous ethanol injection, or PEI. With ultrasound guided placement of a 25 gauge needle within the cyst, and after evacuation of the cyst fluid, about 50% of the cyst volume is injected back into the cavity, under strict operator visualization of the needle tip. The procedure is 80% successful in reducing the cyst to minute size.
  • Metastatic thyroid cancer neck lymph nodes: The other thyroid therapy use for HFUS is to treat metastatic thyroid cancer neck lymph nodes that occur in patients who either refuse surgery, or are no longer a candidate for surgery. Small amounts of ethanol are injected under ultrasound guided needle placement. A blood flow study is done prior to the injection, by power doppler. The blood flow can be destroyed and the node become inactive, although it may still be there. Power doppler visualized blood flow can be eradicated, and there may be a drop in the cancer blood marker test, thyroglobulin, TG, as the node become non-functional. Another interventional use for HFUS is to mark a cancer node one hour prior to surgery to help locate the node cluster at the surgery. A minute amount of methylene dye is injected, under careful ultrasound guided placement of the needle on the anterior surface, but not in the node. The dye will be evident to the thyroid surgeon when opening the neck. A similar localization procedure with methylene blue, can be done to locate parathyroid adenomas at surgery.
  • Joint injections can be guided by medical ultrasound, such as in ultrasound-guided hip joint injections.



Other Siemens probes we can offer:

 

BrandModelCompatible System
Siemens3.5C55SG50/X150/X300
Siemens6C1HDS2000
Siemens7.5L40AG20/G40
Siemens7.5L75SG20 and Prima / Adara
SiemensC7F2Antares/ X300 and X500
SiemensCH4-1Antares
SiemensCH5-2G40/G60/X150/X300
SiemensCH6-2Antares
SiemensCX5-2Antares/ Sonoline Elegra
SiemensC6-2CV70/ G50/G60/ X300/X500
SiemensC6F3G50/G60
SiemensC5F1Antares
SiemensC8-5X300
SiemensP10-4Antares
SiemensPH4-1Antares
SiemensP4-2G50/G60/CV70/X150/X300/X500
SiemensP5-1X300, X300PE
SiemensEC9-4G40/ X150/ X300/Antares
SiemensEV9F4X300 and Antares
SiemensVFX9-4Antares
SiemensVF13-5spAntares/X300/X500/G50/G60
SiemensVFX13-5Antares
SiemensVF13-5X150/X300/X500/G40 /G50/G60/ Sonoline Sienna/Sonoline Elegra
SiemensVF13-5Antares
SiemensVF10-5Antares
Siemens4V1CSequoia 512 GI, Sequoia C512, S2000
Siemens/Acuson4V1Sequoia
Siemens/Acuson6L3Acuson Sequoia
Siemens/Acuson8C4Sequoia 512 G /Sequoia C512
Siemens/Acuson8L5Sequoia 512
Siemens/Acuson8V5Sequoia
Siemens/Acuson7L3Cypress
Siemens/Acuson8V3Sequoia 512 /S1000
Siemens/Acuson9EVF4S1000/ S2000 and S3000
Siemens/Acuson9L4Acuson S2000/ Sequoia/Sequoia C512
Siemens/Acuson10V4Sequoia
Siemens/Acuson15L8WSequoia 512
Siemens/Acuson15L8Sequoia
Siemens/Acuson17L5HDSequoia 512
Siemens/Acuson18L6HDS1000, S2000, S3000
Siemens/AcusonAUX CWCypress / Cypress CV System
Siemens/AcusonC3Aspen
Siemens/AcusonEC9-4G40/ G60/X150/ X300
Siemens/AcusonEC7Aspen/ XP128
Siemens/AcusonEV-8C4Sequoia 512/ S2000
Siemens/AcusonEC-10C5Sequoia 512
Siemens/AcusonL5Aspen
Siemens/AcusonL7Aspen/128XP-10
Siemens/AcusonTE-V5MSequoia/ Sequoia C512/Sequoia 512/ Aspen/ Cypress/S1000/S2000
Siemens/AcusonTE-V5MsCypress/Sequoia/S2000/X300 systems
Siemens/AcusonV4Aspen/ XP
Siemens/AcusonV7Aspen/ XP


 

 

Common ultrasonic Probe Damage(Convex, Linear, Sector, Endocavity probes)

 

Common ultrasonic probe damageSolutions
Lens damage, wear, holes, swelling, delaminationLens replacement
Strain relief damage, separationStrain replacement
Nosepiece and probe separation and cracksStrain replacement
Cable cutsCable patches, possible cable replacement
Connector housing electrical damageMajor and minor electrical repairs, pin module replacement

 

Hot Products

Cypress 4C1 Convex Ultrasound Transducer Probe Abdominal Vascular Applications Hospital Used Siemens ...
Siemens C7F2 3D/4D Curved Array Ultrasound Transducer Probe Acuson Antares Medical Use Siemens C7F2 ...
Siemens X300 EV9-4 Endocavity Transducer Echo Ultrasound Scanner Probe Medical Equipment Siemens EV9...
Siemens P4 2 Phased Array Probe Cardiac No Allergic Reaction Healthcare Solutions Siemens P4-2 ...
Clearvue Ultrasound Spare Parts 4D Trackball 453561451331 1, Model: 453561451331 2, Description: 4D ...
ClearVue Ultrasound Spare Parts Alphanumeric Keyboard 1, Brand: 2, Description:Alphanumeric Keyboard ...