GE RAB4-8-RS Ultrasound Probe Repair Dome Original Condition Oil Filling

Country/Region china
City & Province guangzhou guangdong
InquireNow

Product Details

GE RAB4-8-RS Ultrasound Probe dome Repair Original Condition Oil Filling

 

The dome is damaged and leaking oil

 

Suggestion: replace the dome (filling oil)

 

 

 

Other hot GE models we can repair:

 

GEC1-5-D
GEC1-5-RS
GE4C
GE4C-RS
GE4C-A
GE4C-D
GE4C-SC
GEE8C/E8C-RS
GEE8CS
GERIC5-9-D
GE3CRF-D
GEC1-6-D
GERAB4-8-RS
GERAB2-5-RS
GE6S-RS
GE12L-RS
GE3SC-RS
GEL6-12-RS
GE11L
GE11L-D
GE12L-RS
GE8C
GE3S
GE3S-RS
 

 

 

 

Common ultrasound Probe Damage(Specialty 3D/4D Volume probes)

 

Common ultrasound probe damageSolutions
Lens cap damageLens cap replacement
Fluid and oil leaksLens cap replacement, oil reservoir repair and replacement
Cable cutsCable patches, possible cable replacement
Inoperative steeringMotor repair
Connector housing electrical damageMinor electrical repairs, pin module replacement
Weak or dead elements, dropouts in an imageArray ball replacement, oil reservoir repair and replacement

 

 

 

 

 

 

 

 

Warnings and cautions of the ultrasonic probe

 

The ultrasonic probe is a valuable device. It must be careful in the process of use. Avoid dropping, impact, or abrasion to transducers.

When installing or removing the probe, first switch off the power and then operate it carefully.

Avoid rapid and extreme temperature changes, as well as lengthy exposure to direct sunlight or a strong ultraviolet light source.

Do not use sharp objects to penetrate the acoustic lens.Once the acoustic lens is damaged, the coupling gel is easy to enter the interior of the probe and damage the piezoelectric element.

Do not soak transducer in any liquid above the recommended level as stated in the user manual for your system, please operate according to the manufacturer's instructions, otherwise it will lead to circuit failure or even burn out.

Do not disinfect at high temperature, because the probe is equipped with piezoelectric ceramics, high temperature will weaken the effect.

Before use, carefully check whether the housing and cable are damaged, so as to prevent the probe from high voltage injury.

After the probe is used, the residual coupling gel on the probe must be wiped clean to prevent rats or other animals from gnawing the lens.



Hot Products

Toshiba PVU-781VT Endocavity Array Ultrasonic Probe Transducer Used in Hospital 1.Type:Endovaginal 2...
GE RAB4-8-RS Ultrasound Probe dome Repair Original Condition Oil Filling The dome is damaged and ...
Toshiba PSU-25BT 5S1 4.2 MHz Cardiac Array Sector Ultrasound Transducer Probe 1.Type:Sector 2...
Toshiba PLT-805AT Ultrasound Machine Linear Array Ultrasoni Probes Original Transducer 1.Type: ...
GE Logiq e Voluson i 9L-RS Linear Array Transducer ultrasound probe 1. Type: linear 2. Frequency: 3...
GE 4C Convex Array Ultrasound Transducer Used Probe Use in Hospital Diagnosis Machine 1.Type: convex ...