Home Products Electrical Equipment & Supplies Wires, Cables & Cable Assemblies

transformer triple insulated wire

Refine Search
Results fortransformer triple insulated wirefrom 31806 Products.
Conductor Insulation Max.Cond Resistance Unit length Size (AWG) Construction (No./mm) Diameter (mm) Nominal Thickness (mm) Diameter (mm) (Ω/KM) (M)(Ft) 26 7/0.16 0.48 0.60 1.68 143 ...
Guangdong, china
Verified
Conductor Insulation Max.Cond Resistance Unit length Size (AWG) Construction (No./mm) Diameter (mm) Nominal Thickness (mm) Diameter (mm) (Ω/KM) (M)(Ft) 26 7/0.16 0.48 0.60 1.68 143 ...
Guangdong, china
Verified
Conductor Insulation Max.Cond Resistance Unit length Size (AWG) Construction (No./mm) Diameter (mm) Nominal Thickness (mm) Diameter (mm) (Ω/KM) (M)(Ft) 10 19/0.61 3.07 1.45 5.97 3...
Guangdong, china
Verified
Products Description Product Paramenters Rated voltage : 600V Rated Temperature : 200°C Standard : UL1330 Conductor Insulation Max.Cond Resistance Unit length Size (AWG) Constructi...
Guangdong, china
Verified
Products Description Product Paramenters Rated voltage : 600V Rated Temperature : 200°C Standard : UL1330 Conductor Insulation Max.Cond Resistance Unit length Size (AWG) Constructi...
Guangdong, china
Verified
Products Description Product Paramenters Rated voltage : 600V Rated Temperature : 200°C Standard : UL1330 Conductor Insulation Max.Cond Resistance Unit length Size (AWG) Constructi...
Guangdong, china
Verified
Products Description Product Paramenters Rated voltage : 600V Rated Temperature : 200°C Standard : UL1330 Conductor Insulation Max.Cond Resistance Unit length Size (AWG) Constructi...
Guangdong, china
Verified
Products Description Product Paramenters Rated voltage : 300V Rated Temperature : 150°C Standard : UL758 Conductor Insulation Max.Cond Resistance Unit length Size (AWG) Constructio...
Guangdong, china
Verified
Specification Conductor Insulation Jacket Diameter (mm) Size (AWG) Construction (No./mm) Diameter (mm) Thickness (mm) Thickness (mm) 2*18 7/0.39 1.17 0.45 0.4 5.5-7.0 2*16 7/0.49 1...
Guangdong, china
Verified
UL3137 600V 150C Factory directly sell for home appliance,lighting,heater,motor&generator,UAV,cobot,industrial. Specification Conductor Insulation Max.Cond Resistance Unit length ...
Guangdong, china
Verified
Specification CONDUCTOR INSULATION MAX.COND RESISTANCE (Ω/KM) UNIT LENGTH (M)(FT) SIZE (AWG) CONSTRUCTION (NO./mm) DIAMETER (mm) NOMINAL THICKNESS (mm) DIAMETER (mm) 28 1/0.32 0.32 ...
Guangdong, china
Verified
Specification Conductor Insulation Max.Cond Resistance (Ω/KM) Unit length (M)(Ft) Size (AWG) Construction (No./mm) Diameter (mm) Nominal Thickness (mm) Diameter (mm) 30 7/0.1 0.3 0...
Guangdong, china
Verified
Specification Conductor Insulation Max.Cond Resistance Unit length Size (AWG) Construction (No./mm) Diameter (mm) Nominal Thickness (mm) Diameter (mm) (Ω/KM) (M)(Ft) 30 7/0.1 0.3 0...
Guangdong, china
Verified
Products Description Specification Table Conductor Insulation Max.Cond Resistance (Ω/KM) Unit length (M)(Ft) Size (AWG) Construction (No./mm) Diameter (mm) Nominal Thickness (mm) ...
Guangdong, china
Verified
Products Description Specification Table Conductor Insulation Max.Cond Resistance (Ω/KM) Unit length (M)(Ft) Size (AWG) Construction (No./mm) Diameter (mm) Nominal Thickness (mm) ...
Guangdong, china
Verified
Products Description Specification Table Conductor Insulation Max.Cond Resistance (Ω/KM) Unit length (M)(Ft) Size (AWG) Construction (No./mm) Diameter (mm) Nominal Thickness (mm) ...
Guangdong, china
Verified
Products Description Specification Table Conductor Insulation Max.Cond Resistance (Ω/KM) Unit length (M)(Ft) Size (AWG) Construction (No./mm) Diameter (mm) Nominal Thickness (mm) ...
Guangdong, china
Verified
Specification Table Conductor Insulation Max.Cond Resistance (Ω/KM) Unit length (M)(Ft) Size (AWG) Construction (No./mm) Diameter (mm) Nominal Thickness (mm) Diameter (mm) 26 7/0...
Guangdong, china
Verified
Specification Table Conductor Insulation Max.Cond Resistance (Ω/KM) Unit length (M)(Ft) Size (AWG) Construction (No./mm) Diameter (mm) Nominal Thickness (mm) Diameter (mm) 26 7/0...
Guangdong, china
Verified
Specification Table Conductor Insulation Max.Cond Resistance (Ω/KM) Unit length (M)(Ft) Size (AWG) Construction (No./mm) Diameter (mm) Nominal Thickness (mm) Diameter (mm) 12 19/0...
Guangdong, china
Verified
Page 46 of 50 |< << 40 41 42 43 44 45 46 47 48 49 50 >> >|