Home Companies Changsha Panran Technology Co., Ltd.

High Precision ±0.003 ° C Temperature Transmitter Calibration

Changsha Panran Technology Co., Ltd.
Active Member

Contact Us

[China] country

Address: Room 504,Floor 5th,Chuangye Building, Hu-Da park,No186,Guyuan Road,High-Tech District,Changsha,Hunan ,China. (Zipcode: 410205)

Contact name:PANRAN

Inquir Now

Changsha Panran Technology Co., Ltd.

High Precision ±0.003 ° C Temperature Transmitter Calibration

Country/Region china
City & Province changsha hunan
InquireNow

Product Details

Displays Input And Output Simultaneously Of Thermometer Calibrator

 

PANRAN Temperature Calibrators simulate process sensors for testing temperature instrumentation.

Specifically designed for the field, these lightweight compact tools are EMI tolerant, dust and splash resistant and offer an easy to use single push button interface. When paired with a temperature sensor they can take high accuracy temperature measurements to verify process temperatures and ensure the highest product quality and safety. There are a variety of different temperature calibrators designed for your unique calibration and testing requirements.

PANRAN offers a wide range of temperature calibration equipment. Everything from simple Stik Thermometers to temperature simulation/measurement calibrators to dry-blocks, micro-baths and metrology wells. Whether you’re looking to calibrate a temperature transmitter in the field, test an RTD sensor, simulate a thermocouple, or calibrate a temperature transmitter at the bench, PANRAN has a temperature calibrator for you.

 

  • Products Features

 

 

 

 

 

Powerful, easy-to-use, high-accuracy temperature calibrator
Test and calibrate temperature sensors and transmitters
Measures 4 to 20 mA loops and can provide loop power
Measures RTDs, thermocouples, ohms, and volts
Source/simulates thermocouples, RTDs, volts, and ohms

 

Precision temperature control function

Using the precision temperature control function, temperature closed-loop control of the constant temperature equipment can be realized instead of the high-precision PID controller. In the case that the constant temperature equipment and grid voltage are satisfactory to the conditions, the temperature fluctuation of the equipment can be better than 0.02°C /10min (thermostatic bath).

 

ρvalue measurement

The PR231 series calibrator can measure the duty factor of the periodic square signal and can be used to verify and calibrate the PID parameters of various digital temperature indicating regulators for time proportional output, and meet the requirements of JJG 617-1996 Verification Regulation of Digital Temperature Indicators and Controllers.

 

thermal calculator

It is used to achieve various conversions between electric and temperature. The conversion support a variety of TCs, RTDs and thermistors.

 

Value Settings

The PR231 series calibrator has the most flexible and convenient output value setting method. It is possible to directly set the output value through the numeric keypad, or to increase the increment setting by pressing the direction key. In addition, the device has an editable phase step or slope value setting method.

 

Sinusoidal signal output function

The verification/calibration of some process loggers, especially mechanical recorders, usually involves the operation test. In this case, the user can use the device's sinusoidal signal output function to provide signals for the verified instrument.

 

 

The verification/calibration of some process recorders (especially mechanical recorders) usually involves the operation of the test. At this time, the device's sinusoidal signal output function can be used to signal the meter.

 

Data logging function

The logging function saves measurement and output data. PR231 series calibrator has powerful record management functions. Up to 32 device numbers can be created. Each device number has 16 logging pages. Each logging page contains four kinds of basic information, namely time, measured value, output value and custom value. Basic information. Users can perform device processing, record deletion, etc. according to their needs.

 

  • PR231 series model selection table

ItemPR231A-1PR231A-2PR231B-1PR231B-2
Enhancement model
  •  
  •  
  
Basic model  
  •  
  •  
0.01 grade
  •  
 
  •  
 
0.02 grade 
  •  
 
  •  

 

  • Basic Parameters

Weight990gcharging source100~240V AC,50~60Hz
Dimension225mm*130mm*53mmWorking temperature-10℃~50℃
Cell type7.4V 4400mAh, Rechargeable lithium batteryWorking time≥20 hours(24V power off)
Preheating time10 minutes after preheatingHumidity0~80%,Non condensing
Charging time5 hoursCalibration period2 years

 

 

 

  • Performance Index

1. Basic parameters of measurement:

FunctionRangeMeasurement rangeResolution0.01 accuracy0.02 accuracyRemarks
Voltage100mV-5mV~120mV0.1uV0.005%RD+5uV

0.015%RD+

5uV

Input impedance

≥80mΩ

1V-50mV~1.2V1uV

0.005%RD+

0.005%FS

0.015%RD+

0.005%FS

10V-0.5V~12V10uV

Input impedance

≥1mΩ

50V-0.5V~50V0.1mV
Current50mA-5mA~50 mA0.1uA0.005%RD+0.005%FS

0.015%RD+

0.005%FS

Internal resistance =10Ω
Ohm50Ω0Ω~50Ω0.1mΩ0.005%RD+5mΩ

0.015%RD+

5mΩ

Output 1mA current
500Ω0Ω~500Ω1mΩ0.005%RD+0.005%FS

0.015%RD+

0.005%FS

5kΩ0kΩ~5kΩ10mΩOutput 0.1mA current
Thermal coupleS,R,B,K,N,J,E,T,EA2,Wre3-25,Wre5-260.1℃/According to ITS-90 scale
Cold end compensationInternal-10℃~60℃0.01℃0.5℃0.5℃
External0.1℃0.1℃

Thermal

resistance

Pt10,Pt100, Pt200,Cu50,Cu100,BA1,BA2,JPt100, Pt500, Pt10000.01℃/
Standard temperatureS,R,B,T,SPt25,SPt1000.01℃/Need to enter the correction value
ρ-value50S0.001%~99.999%0.001%0.005%0.005%Input pulse width amplitude range:1V~50V
Frequency10Hz0.001Hz~12Hz0.001Hz0.01%FS0.01%FS
1kHz

0.00001kHz~

1.2 kHz

0.01Hz
100kHz

0.01kHz~

120 kHz

10Hz0.1%FS0.1%FS
Temperature differenceS,R,B,K,N,J,E,T0.01℃/Need to enter the correction value
SPt25,SPt1000.001℃

 

2. Basic parameters of the output function:

FunctionRange

Measurement

range

Resolution0.01 accuracy0.02 accuracyRemarks
Voltage100mV-20mV~120mV1uV0.005%RD+5uV0.015%RD+5uVMaximum load current =2.5mA
1V-0.2mV~1.2V10uV0.005%RD+0.005%FS0.015%RD+0.005%FS
10V-2V~12V0.1mV
Current30mA-5mA~30 mA1uA0.005%RD+0.005%FS0.015%RD+0.005%FSMaximum load voltage =24V
Ohm50Ω0Ω~50Ω0.1mΩ/According to ITS-90 scale
500Ω0Ω~500Ω1mΩ
5kΩ0kΩ~5kΩ10mΩ
Thermal coupleS,R,B,K,N,J,E,T,EA2,Wre3-25,Wre5-260.1℃/

Thermal

resistance

Pt10,Pt100, Pt200,Cu50,Cu100,BA1,BA2,JPt100, Pt500, Pt10000.01℃/

Frequency

/ Pulse

10Hz

0.001Hz~

12 Hz

0.001Hz0.01%FS0.01%FSMaximum load current =2.5mA
1kHz

0.00001kHz~

1.2 kHz

 

0.01Hz

100kHz0.01kHz~120 kHz10Hz0.1%FS0.1%FS
Precision temperature controlS,R,B,K,N,J,E,T0.01℃/
Pt100
24V output

Maximum voltage error: 0.3V Ripple noise:35mVp-p(20MHz bandwidth)

Maximum load current:70mA Load regulation: 0.5%(10% -100% load change)

 

 

  • DETAILS INTRODUCE

 

   1. Measuring function terminal area (withstand 100V DC voltage input error)

2. Output function terminal area(withstand 36V DC voltage input error)

3. Dust cover

4. Side band(length adjustable )

5. Holder

6. External Pt100 Reference point sensor interface

7. USB2.0 communication interface

8. Multi-function port (With RS232 communication, USB communication, isolated 24V voltage output, precision temperature control signal output, pressure calibration, and other functions)

9. Reset

10. Supply hub(Connect the external AC power adapter)

11. Equipment nameplate

12. Battery

13.Protective tube

14.Screen contrast adjusting knob

15.Battery port

 

a.Adjust length here

b.Unfold jacket toward this direction

c. Holder unfold direction

 

Hot Products

Source/Simulates Thermocouples, RTDs, Volts, And Ohms From Multimeter Calibrator For Lab Application...
Portable Multifunction Calibrator That Measures Sources Functions To Test The Temperature Calibrator ...
Displays Input And Output Simultaneously Of Thermometer Calibrator PANRAN Temperature Calibrators ...
Handheld Temperature Calibrator For All Thermocouple Types And Transmitters The PANRAN PR231 is ...
Small, Streamlined Shape Reliable Design That Stands Up To Field Use Multi-Function Calibrator ...
Documenting And Communication Function Built Into Multifunction Calibrator The Thermocouple ...