4P 385V 100kA Surge Protection Device SPD For Lower Voltage Power System

 

OBV-II100-3 data

 

Uc(maximum continuous operating voltage)385V
Imax(maximum discharge current)10kA
In(nominal discharge current for class II test)20kA
Up(voltage protection level)≤2.5kv
response time≤25ns
Signal deterioration indicationred: need replace
green: work
Housing MaterialFlame retardant plastic
Housing self-extinguishing classUL94_V0
Temperature range-40℃+85℃
humidity range≤95%
Elevational≤3000m
Method of connecting wiremultiple
(Connect In Parallel )
Thread Dimensions6mm2~35mm2
Mounting method35mm standard rail installation
IP(degree of protection of enclosure)IP20
application standardGB18802-1;IEC61643-1


 

The classification of the SPD
1. According to the working principle divided:voltage switching type SPD, voltage limiting type SPD , voltage cobination type SPD
2. According to the use of points : power system surge protection device, signal system surge protection device

 

Installation Instructions:
1. Power must be cut off before installation, and live operation is strictly prohibited
2. It is suggested to connect the fuse or automatic short-circuit in series at the front end of the lightning protection module
3. Please connect according to the installation diagram, where + is the positive wire, - is the negative wire, and PE is the ground wire. Don't make a mistake. After the installation is completed, close the switch and check whether the working condition is normal
4. Insert the module in place after installation and check whether the lightning protection module works normally
5. During the use of SPD, it should be regularly monitored and checked the status of the fault display window. When the fault display window is red or the remote terminal output an alarm signal, it indicates that the lightning protection module has broken down and should be repaired or replaced in time
6. Lightning protection module should be installed in parallel, and the connecting line should be firm and reliable, and it should be short, thick and straight

Hot Products

PCB On Board Design Surge Protection Device For PV System With Thermal Response​ Ucpv(maximum ...
Lower Voltage 385V 100kA Surge Protection Device In 27MM DEHN Contruction OBV-II100-1 data Uc...
4P Lower Voltage 275V 20kA Surge Protection Device SPD For Power System OBV-II20 data Uc(maximum ...
Class III IP20 1500V 3P 40kA Surge Protection Device for house use Uc(maximum continuous operating ...
4P 385V 100kA Surge Protection Device SPD For Lower Voltage Power System OBV-II100-3 data Uc(maximum ...
Type 2 Surge Protector for house use lower voltage 385V Uc(maximum continuous operating voltage) ...