Home Companies Guangdong Uchi Technology Co.,Ltd

Rapid Transmission Rate CCTV Surge Protection Device CQC For UPS System

Guangdong Uchi Technology Co.,Ltd
Active Member

Contact Us

[China] country

Address: Floor 4, NO.25-29,Power Station Road, Xihu , Shilong Town , Dongguan 523325, China.

Contact name:Amy

Inquir Now

Guangdong Uchi Technology Co.,Ltd

Rapid Transmission Rate CCTV Surge Protection Device CQC For UPS System

Country/Region china
City & Province dongguan
Categories Uninterrupted Power Supply (UPS)
InquireNow

Product Details

CCTV Surge Arrester Protection Device for combination video signal and AC power

 

CCTV Surge Protector


CCTV surge protector is a single channel, in-line, coaxial multi-stage video surge protector for analog cameras or head-end applications. CCTV camera surge protector is designed to provide multi-stage surge protection for one channel of video. The unit has MNC type connectors at the input and output for connection to the coax and is ideally suited for small or restricted spaces where a single line of video needs to be protected. CCTV Surge Protector provides power to the camera with the same unit.

 

 

Technical Parameters

 

Model: OBVX-3-BNC / OBVX-2-RJ45 / OBVX-2-BNC
Power
Nominal Voltage Un24Vdc120Vac230Vac
Maximum Voltage Uc30Vdc150Vac255Vac
Line Current IL5A
Nomimal Discharge Current In (8/20µs) kA5kA
Maximum Discharge Current Imax (8/20µs)10kA
Protection Level Up0.3kV0.8kV1.2kV
ConnectionScrew terminal : maximum 2.5 mm2
Failure ModePower failure and green led off
Data
Maximum Voltage Uc8Vdc
Nomimal Discharge Current In (8/20µs) kA5kA
Maximum Discharge Current Imax (8/20µs)10kA
Protection Level Up20V
ConnectionScrew terminal : maximum 1.5 mm2
Failure ModeShort-circuit status (transmission fault)
Video (BNC / RJ45)
Maximum Voltage Uc6Vdc
Nomimal Discharge Current In (8/20µs) kA5kA
Maximum Discharge Current Imax (8/20µs)10kA
Protection Level Up20V
ConnectionBNC female coaxial connector / RJ45
Failure ModeShort-circuit status (transmission fault)

 

Feature&Benefits
 

1. Multi-function over-voltage protection, simple structure, less residual voltage, rapid transmission rate.

2. Applicable for combination video signal and AC power.

3. Convenient installation, maintenance simply.


Application


●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers
 

Installation and Maintenance

 

1. Fix the surge protective device on the wall or place the plane, connect the wire according to drawing.

2. PE connect with the earthing, Earth resistance should accord with the standard of lightning protection.

3. The distance should be within 1 meter between being protection device and surge protective device.

4. Surge protective device will damaged and signal interrupter when maximum continuous operating voltage overrun.

5. When its maximum continuous operating voltage overrun, surge protective device will damaged, if happened, please
remove surge arrester immediately and choose suited surge protective device.

 

Note: Lightning protection is probabilistic protection, and we cannot provide 100% protection.


First, lightning discharge itself has a certain degree of randomness, and lightning parameters have certain statistical properties, which determines that all protective measures based on these statistical characteristics of lightning parameters cannot provide 100% protection. Such as: direct lightning protection-shielding characteristics; lightning current amplitude, waveform, etc. have statistical properties;
Second, the lightning protection equipment cannot prevent the formation of lightning flashes;
Third, lightning protection devices cannot ideally eliminate all interference voltages/currents. The fundamental purpose of taking protective measures is to ensure that most of the energy caused by interference does not spread to the vulnerable parts of the device and the staff.
Finally, the cost of protection against high-level surges with a small probability of occurrence has risen sharply.


Others


Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):

Type No.Rated Voltage(V) UnContinuous Voltage Uc(V~)Standard Discharge Current In(KA)

Max Discharge Current
Imax(KA)

Protection Level(KA~)Response Time(ns)
DGM1(2)-D5220/380

275/320
385/420

5101.2≤25
DGM1(2)-D101021.6
DGM1(2)-C2020401.8
DGM13-B303060.2.2
DGM3(4)-B4010802.4
DGM(4)-B60601002.8
DGM-N-PE220/25540/6060/801.2≤100

 

Tip: How can I distinguish the quality of the lightning arrester?

1. It can be seen from the reaction time: determine whether the lightning arrester can respond in time and quickly discharge the lightning current.

2. It can be seen from the insertion loss: this refers to the installation of a lightning protector, the impact of this lightning protector on the line, the smaller the better

3. It can be seen from the number of impact resistance: determines the service life of the lightning arrester. Generally, the gas discharge tube will not drop after being placed for a period of time. If you want to check its quality, you can use an adjustable high-voltage DC power supply to test .

 
*The main parameters of the lightning arrester

(1) Nominal voltage Un: The additional voltage of the maintained system is consistent with it. In the information technology system, this parameter indicates the type of maintainer that should be selected, and it indicates the effective value of the communication or DC voltage.
(2 Maximum continuous voltage Uc: The maximum effective voltage value that can be permanently applied to the designated end of the lightning protector without causing changes in the characteristics of the lightning protector.
(3) Nominal discharge current In: The lightning protection device is not damaged by applying a standard lightning wave with a waveform of 8/20μs to the lightning protection device for 10 times.
(4) Maximum discharge current Imax: The peak value of the maximum impulse current that the lightning protector can withstand when a standard lightning wave with a waveform of 8/20μs is applied to the lightning protector for one impact.
(5) Voltage protection level Up: The voltage protection level of the lightning arrester in the case of In.
When selecting the type, the Uc of the lightning arrester must meet the system voltage, the flow rate must meet the use requirements, and the protection level must be lower than the equipment withstand voltage.
 
FAQ

 
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
 
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are available.
 
Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
 
Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc.

Hot Products

10KA CCTV Surge Protection Device , Security Camera Surge Protector CCTV Surge Protector CCTV surge ...
6VDC CCTV Lightning Protection , BNC,RJ45 Surge Protection Device CCTV Surge Protector CCTV surge ...
In 5kA And Imax 10KA CCTV Lightning Arrester , 6VDC Surge Protection Device CCTV Surge Protector ...
Camera Surge Protector , CCTV Surge Protection Device 20V Protection level up CCTV Surge Protector ...
CCTV Surge Arrester Protection Device for combination video signal and AC power CCTV Surge Protector ...
10KA RJ45 Power Surge Arrester , CCTV Surge Protection Device CCTV Surge Protector CCTV surge ...