S5731S-S48S4X-A (98011806)
 

Overview

Table 4-1375 Basic information about the S5731S-S48S4X-A
ItemDetails
DescriptionS5731S-S48S4X Bundle(48*GE SFP ports, 4*10GE SFP+ ports, with AC power supply)
Part Number98011806
ModelS5731S-S48S4X-A
First supported versionV200R021C01

 

Components

Figure 4-539 S5731S-S48S4X-A appearance
1Forty-eight 100/1000BASE-X ports2Four 10GE SFP+ ports
3One console port4One ETH management port
5

One PNP button

NOTICE:

To restore the factory settings and reset the switch, hold down the button for at least 6 seconds.

To reset the switch, press the button.

Resetting the switch will cause service interruption. Exercise caution when you press the PNP button.

6

Ground screw

NOTE:
It is used with a ground cable.
7

Power module slot 1

8

Power module slot 2

Indicators and Buttons

The S5731S-S48S4X-A has the same types of indicators as the S5731S-S32ST4X-A. For details, see the S5731S-S32ST4X-A.

Power Supply System

The switch can use a single power module or double power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch. However, the power modules with natural heat dissipation and the power modules with fan cannot be used at the same time.

Heat Dissipation System

The switch has three built-in fans for forced air cooling. Air flows in from the left, right, and front sides, and exhausts from the rear panel.

 

Technical specifications of the S5731S-S48S4X-A
ItemSpecification
Dimensions without packaging (H x W x D) [mm(in.)]

Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.)

Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 448.0 mm (1.72 in. x 17.40 in. x 17.64 in.)

Dimensions with packaging (H x W x D) [mm(in.)]185 mm x 650 mm x 550 mm (7.28 in. x 25.59 in. x 21.65 in.)
Chassis height [U]1 U
Weight without packaging [kg(lb)]5.9 kg (13.01 lb)
Weight with packaging [kg(lb)]8.43 kg (18.58 lb)
Typical power consumption [W]93.69 W
Typical heat dissipation [BTU/hour]319.68 BTU/hour
Maximum power consumption [W]

128.89 W (150 W AC or 180 W DC)

141.96 W (600 W AC)

Maximum heat dissipation [BTU/hour]

439.79 (150 W AC or 180 W DC)

484.38 (600 W AC)

Static power consumption [W]50.44 W
MTBF [year]64.97 year
MTTR [hour]2 hour
Availability>0.99999
Noise at normal temperature (acoustic power) [dB(A)]45.47 dB(A)
Noise at normal temperature (acoustic pressure) [dB(A)]31.79 dB(A)
Number of card slots0
Number of power slots2
Number of fans modules3
Redundant power supply

1+1

Pluggable AC and DC power modules can be used together in the same switch, but power modules that use natural heat dissipation and power modules that use air cooling cannot be used together.

Long-term operating temperature [°C(°F)]-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
Short-term operating temperature [°C(°F)]-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)
Restriction on the operating temperature variation rate [°C(°F)]

When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met:

  • The operating temperature can exceed 45°C (113°F) for a maximum of 96 consecutive hours in a year.
  • The total time when the operating temperature exceeds 45°C (113°F) in a year is less than or equal to 360 hours.
  • The number of times the operating temperature exceeds 45°C (113°F) is less than or equal to 15 in one year.

If any of the preceding conditions is not met, the device may be damaged or an unknown error may occur.

Devices cannot start when the temperature is lower than 0°C (32°F). The maximum transmission distance of an optical module used for short-term operation cannot exceed 10 km.

Storage temperature [°C(°F)]-40°C to +70°C (-40°F to +158°F)
Long-term operating relative humidity [RH]5% to 95%, noncondensing
Long-term operating altitude [m(ft.)]0-5000 m (0-16404 ft.)
Storage altitude [m(ft.)]0-5000 m (0-16404 ft.)
Power supply modePluggable power supply
Rated input voltage [V]
  • AC input: 100 V AC to 240 V AC, 50/60 Hz
  • High-voltage DC input: 240 V DC
  • DC input: –48 V DC to –60 V DC
Input voltage range [V]
  • AC input: 90 V AC to 290 V AC; 45 Hz to 65 Hz
  • High-voltage DC input: 190 V DC to 290 V DC
  • DC input: -38.4 V DC to -72 V DC
Maximum input current [A]The current specifications depend on the pluggable power modules in use. For details, see the related power module specifications.
Memory2 GB
Flash memoryThe physical space is 1 GB. You can run the display version command to view the actual available space.
Console portRJ45
Eth Management portRJ45
USBNot supported
RTCSupported
RPS inputNot supported
Service port surge protection [kV]-
Power supply surge protection [kV]
  • Configured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode
  • Configured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode
Types of fansBuilt-in
Heat dissipation modeHeat dissipation with fan, intelligent fan speed adjustment
Airflow directionAir intake from left,front and right, air exhaustion from behind
PoENot supported
Certification

EMC certification

Safety certification

Manufacturing certification

Notices:

1. Open the packaging, check the products carefully, and take them gently.
2. The product is a brand new original unopened equipment.
3. All products 3 year warranty, and the buyer is responsible for the return shipping cost.

International Buyers Please Note:
Import duties, taxes, and charges are not included in the item price or shipping cost. These charges are the buyer's responsibility.
Please check with your country's customs office to determine what these additional costs will be prior to bidding or buying.
Customs fees are normally charged by the shipping company or collected when you pick the item up. These fees are not additional shipping charges.
We won't under-value merchandise or mark the item as a gift on customs forms. Doing that is against U.S. and international laws.
Customs delays are not the responsibility of the seller.
Inspur NF5270M6/NF5280M5/ NF2180M3/NP5570M5/NF3120M5/NF8480M5
Dell P5820/T7920/R250/R450/R540/R650/R650xs/R740/R750/R750xs
xfusion 2288HV5 2488HV5 5588HV5


Need to contact:
WeChat: +8613651169867
Skype: +8613651169867
WhatsApp: +8615732685076

 

Hot Products

Product Description: Rack Storage Server: Maximum Security, Connectivity, Power and Flexibility Our ...
S5731S-S32ST4X-A1 (98011809) Table 4-1367 Basic information about the S5731S-S32ST4X-A1 Item Details ...
S5731S-S48S4X-A (98011806) Overview Table 4-1375 Basic information about the S5731S-S48S4X-A Item ...
S5731S-S24T4X-A (98011852) Overview Table 4-1321 Basic information about the S5731S-S24T4X-A Item ...
S5731S-S24P4X-A (02353AHY/02353AHY-001/02353AHY-003) Version Mapping Table 4-1327 lists the mapping ...
S5731S-S48T4X-A1 Overview Table 4-1343 Basic information about the S5731S-S48T4X-A1 Item Details ...