Datex Ohmeda Compatible NIBP Hose NIBP Air Hose, MDN22-27 Neonate
Doubule Hose
OEM Part Number Cross References:
Compatibility:
Manufacturer | Model |
---|
Datex Ohmeda | AS/3, CS/3, Cardiocap II, Cardiocap/5, Light, S/5 |
---|
GE Healthcare > Corometrics | 120 |
---|
GE Healthcare > Marquette | Eagle 4000, SOLAR, Tram 100, Tram 200, Tram 250, Tram 300, Tram 350 |
---|
To ensure proper use of the SpO2 sensor and its cable, please
follow these guidelines:
Cleaning: Clean the sensor and cable before each patient use.
Follow the recommended cleaning procedures provided by the
manufacturer or refer to the product documentation.
Sensor Placement: Place the sensor on the index finger, making sure
the finger is fully inserted and the tip of the finger rests
against the finger stop inside the sensor. Alternatively, you can
use small-sized thumb, middle and ring fingers, the little finger,
or the big toe as alternate sites. Ensure that the fingernail is
located under the finger stop on the SpO2 sensor clamp.
Avoid Interference: Do not place the sensor on the same arm as the
blood pressure cuff, arterial catheter, or intravascular line.
Remove all nail polish as it can affect accuracy. Avoid using the
sensor inside or near an MRI, and keep intense light sources away
from the sensor.
Changing Measurement Site: For long-term use, change the
measurement site every 4 hours to maintain the integrity of the
patient's skin.
Restless Patients: In the case of restless patients or excessive
motion, consider using Med Accessories Soft tip, wrap, or
multi-site sensor to help secure the sensor to the patient.
Equipment:
Connect the sensor cable to the appropriate equipment (pulse
oximeter).
Turn on the equipment and ensure its correct operation by
consulting the monitor's operation instructions.
To ensure proper operation of the monitor, periodically connect and
disconnect the sensor cable from the monitor cable.
Systematically check the sensor and cable at least once a month (or
more frequently depending on usage) for appearance, insulators,
connector contact pins, and overall mechanical integrity.
Do not use or discard any sensor that shows mechanical or
electrical flaws.
Operating Conditions:
Ambient temperature: 0°C to +40°C
Relative humidity: 0% to 80%
Atmospheric pressure: 860 to 1060 HPa
Cleaning, Disinfection, or Sterilization:
In departments where sterility levels need to be observed, follow
the recommended cleaning, disinfection, or sterilization methods
provided by Med Accessories or as specified in the product
documentation.
It is essential to follow these guidelines to ensure accurate and
safe measurements with the SpO2 sensor and its connecting cable.
Consult the manufacturer's instructions and guidelines for specific
cleaning and disinfection procedures, as they may vary depending on
the product.