Home Companies Med Accessories Technology Dongguan Co., Ltd.

Far Infrared Adult Spo2 Sensor Masimo Adhesive Tape Disposable Neonate Monitor SpO2 Sensor

Med Accessories Technology Dongguan Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: No.210,211,212,213,214,Building 1,No.12 Industry Western Road,SongShanHu,Dongguan,Guangdong,China.523808

Contact name:Carina

Inquir Now

Med Accessories Technology Dongguan Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Far Infrared Adult Spo2 Sensor Masimo Adhesive Tape Disposable Neonate Monitor SpO2 Sensor

Country/Region china
City & Province dongguan guangdong
Categories Contactors
InquireNow

Product Details

Factory Masimo Adhesive Tape Disposable Neonate/Adult Spo2 Sensor monitor SpO2 sensor

Disposable spo2 sensor-MED ACC_CATALOGE.pdf

OEM Part Number References:

ManufacturerOEM Part #
M4000 (RD SET Adt),4001 (RD SET Pdt),4002 (RD SET Inf),4003 (RD SET Neo Adult / Neonatal)

Compatibility monitor brands:

ManufacturerModel
Mindray > Datascope
Accutorr 3, Accutorr 7, ePM 10M, ePM 12M

 

 
 
1. Product Name:

Medical Manufacturer M Adult/Neonate Disposable SpO2 Sensor for M Radical-7

 
2.Technical Parameters
Red 660nm±3 mm;
Infrared 905nm±5 mm/940nm
Accuracy range: SpO2 range (70~100%) --- ±3%;
Pulse rate declared accuracy range: 30~235bpm, ±2bpm
Usage Specifications:
- Operating temperature: 0-35℃
- Operating humidity: 15-85%RH
- Operating hyperbaric pressure: 88~108kPa
- transportation and Storage temperature: -30~+60℃
- transportation and Storage humidity: 15~80%RH
- transportation and Storage hyperbaric pressure: 85~105kPa
 
3. operation instructions
The above tables list models of Med Accessories disposable sensors for the following four categories of patients: adult (weight greater than 30 kg ),pediatric(10-50 kg weight ),infant (3-20 kg weight ),and neonatal/adult ( weight less than 3 kg or greater than 40kg ). Select the sensor model number that matches the brand of oximeter you are using.
Match the sensor model with your brand of oximeter. A mismatch may cause patient injury, inaccurate measurements or equipment damage. Check the sensor
every 2 hours and reposition to an alternate location every 24 hours. Avoid application of the sensors to edematous or fragile tissue Excessive patient motion,
excessive ambient light, electromagnetic interference, dysfunctional hemoglobin, low perfusion, intra vascular dyes, finger nail polish and long or artificial finger
nails may affect the sensor performance and the accuracy of the measurement Do not use the sensor if it is damaged. Use of a damaged sensor could cause patient
injury or equipment failure. Note: The materials used in the manufacture of the sensor contain no natural latex protein. The materials have undergone extensive
biocompatibility testing. Further information is available upon request.
 

Hot Products

Medical Co2 breathing circuit PM-9000 Mindray Dryline Water Trap with Tube Product Description Med ...
Compatible Neonate/ Adult Disposable Spo2 sensor for main brand monitors. Medical Adult Disposable ...
Burdick Atria Plus/Eclipse Direct-Connect EKG Cable, 10 Leads, AHA, Banana ECG CABLES.pdf ♦ P/N: B...
Masimo Adhesive Tape Disposable Neonate/Adult Spo2 Sensor monitor SpO2 sensor 11Pin ,1pcs/Bag ...
Factory Masimo Adhesive Tape Disposable Neonate/Adult Spo2 Sensor monitor SpO2 sensor Disposable ...
Med Accessories ISO13485 NIBP Cuff Reusable Disposable TPU Material for Infants/Adult Delivery Time: ...