Multipurpose Disposable Spo2 Probe , Medical Pediatric Pulse Oximeter Adhesive Sensor

Country/Region china
City & Province dongguan guangdong
Categories Electronic & Instrument Enclosures
InquireNow

Product Details

OEM Part Number References:

ManufacturerOEM Part #
M

2515 (M-LNCS Neo-3) 

Also 2509,2512,2513 are available.

 

compatible:M RAD-5/RAD-7/RAD-57/RAD-8/RAD-9/RAD-87

 

 

 

1. Product Name:

 

M 2514 Disposable Spo2 sensor Adhesive Tape adult/neonate 11pin

 

2.Technical Parameters

Operating temperature range:  0℃ to 40℃
Storage and transportation temperature range :0℃to 40℃
Relative humidity:0-80%
Atmospheric pressure:860 to 1060 HPa
SpO2 Range (90%-100%)Accuracy ±3 %
SpO2 Range (70%-90%)Accuracy ±3 %
SpO2 range (<69%)no specified
Pulse rate range: 20-250bpmAccuracy ±2 bpm

 

 

3. operation instructions

oximetry sensors are indicated for use in continuous noninvasive monitoring of arterial oxygen saturation and pulse rate. They are fully compatible
replacement sensors intended for use with major brands of pulse oximeters.

Match the sensor model with your brand of oximeter. A mismatch may cause patient injury, inaccurate measurements or equipment damage. Check the sensor

The above tables list models of Med Accessories disposable sensors for the following four categories of patients: adult (weight greater than 30 kg ),pediatric(10-50 kg weight ),infant (3-20 kg weight ),and neonatal/adult ( weight less than 3 kg or greater than 40kg ). Select the sensor model number that matches the brand of oximeter you are using.

every 2 hours and reposition to an alternate location every 24 hours. Avoid application of the sensors to edematous or fragile tissue Excessive patient motion,

nails may affect the sensor performance and the accuracy of the measurement Do not use the sensor if it is damaged. Use of a damaged sensor could cause patient injury or equipment failure. Note: The materials used in the manufacture of the sensor contain no natural latex protein. The materials have undergone extensive

excessive ambient light, electromagnetic interference, dysfunctional hemoglobin, low perfusion, intra vascular dyes, finger nail polish and long or artificial finger

​biocompatibility testing. Further information is available upon request.

 

 

Hot Products

Product Name: Spacelabs Compatible SpO2 Adapter Cable 2.2m OEM Part Number Cross References: ...
Product Name: M22EC40 series Compatible Spo2 extension cable OEM Part Number Cross References: ...
GE Datex Ohmeda Compatible SpO2 Extension Adapter Cable - OXY-ES3 OEM Part Number References: ...
Product Name: Biolight 15-031-0007 SpO2 Extension Sensor Cable OEM Part Number References: ...
OEM Part Number References: Manufacturer OEM Part # M 2515 (M-LNCS Neo-3) Also 2509,2512,2513 are ...
Nellcor Compatible MAX-A,MAX-P,MAX-N Disposable Spo2 sensor OEM Part Number Cross References: ...