Home Companies Med Accessories Technology Dongguan Co., Ltd.

Stable Sidestream ETCO2 Sensor for GE,Philps,Nihon Konden main brands

Med Accessories Technology Dongguan Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: No.210,211,212,213,214,Building 1,No.12 Industry Western Road,SongShanHu,Dongguan,Guangdong,China.523808

Contact name:Carina

Inquir Now

Med Accessories Technology Dongguan Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Stable Sidestream ETCO2 Sensor for GE,Philps,Nihon Konden main brands

Country/Region china
City & Province dongguan guangdong
Categories Electronic & Instrument Enclosures
InquireNow

Product Details

Sidestream ETCO2 For main brands

 

ETCO2 Sensor Catalogue.pdf

 

CO2 Sampling Lines Catalogue(1).pdf

 

ProjectSpecifications
Principle of OperationNon-dispersive infrared(NDIR) single beam optics, dual wavelength, no moving parts.
Initialization TimeCapnogram displayed in less than 3 seconds,full specifications within 3 minutes(At 25°C).
CO2 Measurement Range0 - 114 mmHg; 0 - 15 %; 0 - 15.2 kPa.
CO2 Rise TimeRise Time Less than 80 ms - Adult Reusable or Single-Patient-Use Airway Adapter Less than 80 ms - Infant Reusable
or Single-Patient-Use Airway Adapter.
CO2 Resolution0. 1mmHg ; 0 to 38 mmHg.; 0.25 mmHg ; 39 to 114mmHg.
CO2 Accuracy0 - 40mmHg ±2 mmHg.; 41 - 76mmHg ±5% of reading.; 77 - 114 mmHg ±8% of reading.
Above 80 breaths per minute ±12% of reading. * Note: Gas emperature at 25°C.
CO2 StabilityShort term drift: Drift over four hours shall not exceed 1 mmHg maximum.
Long term drift: Accuracy specification will be maintained over a 120-hour period.
Sampling Frequency100Hz.
Respiration Rate Range3 to 150 breaths per minute.
Respiration Rate Accuracy±1 breath.
CalibrationNo routine user calibration required. An airway adapter zero is required when changing to a different style of airway
adapter.
Airway AdaptersSingle-patient-use or reusable, < 5 cc dead space (adult), < 1 cc dead space infant.
TemperatureOperating: 0 to 40°C; Storage: -40 to 70°C; Transport: -40 to 70°C.
HumidityOperating: 10 to 90% RH, non-condensing; Storage: 10 to 90% RH, non-condensing.;
Transport: 10 to 90% RH, non-condensing.
Atmospheric PressureOperating: 400-800 mmHg; Storage: 400-800 mmHg; Transport: 400-800 mmHg.
Water ResistanceIPX4 - Splash-proof - Sensor only.
Voltage Requirements5VDC ± 5 %.
Power Rating<1.0W Typical; <1.8 W Warm-up.
Sensor Weight<85g.
Sensor SizeDeep*Wide*High:48mm * 24.3mm * 35.5mm.
Cable Length2.4m.

 

 

Hot Products

Good heat 30W / 50W, white / warm white, AC85 - 265V LED flood lighting PL-FL-W-30W/50W Features: ...
Edan Mainstream etCO2 sensor CAPNOSTAT 5 compatible ETCO2 Sensor Specification Project Specification...
6872130 Original Drager CO2 Monitoring Water Lock 12pcs/box Delivery Time: Stock Orders: Our goal is ...
Respiration Rate Measurement Mainstream CO2 Module Ultrasonic Sensor Module PhaseIn, Aeonmed(Oricare...
M2501A Mainstream Capnography HP EtCO2 Sensor for MP5 MP2 X2 Compatibility Manufacturer Model HP ...
MOX4 OXYGEN SENSOR Operating Principle Partial pressure electrochemical Output 9 mV to 13 mV in 210 ...